Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

International Conference on Quantum Information

Two-color Ghost Imaging

Kam Wai Clifford Chan, Malcolm N. O’Sullivan, Mehul Malik, Robert W. Boyd

Published Jan 1, 2008• 8 citations
Publisher

Abstract

We study a quantum ghost imaging system that uses different wavelengths to illuminate the object and the reference detector. We found that the resolution is limited by the wavelength of light illuminating the object.
DOI
10.1364/icqi.2008.jmb49

Related papers

Resolution of ghost imaging for nondegenerate spontaneous parametric down-conversion

Morton H. Rubin, Yanhua H. Shih

We examine the resolution of a ghost imaging system for the case in which the entangled photons are nondegenerate in frequency. The signal photon illuminates the object and is detected by a bucket detector. The idler photon is detected by a point detector. We consider the two cases in which the imaging lens is in the same arm as the object and when it is in the other arm. In the first case, the Airy disk is shown to depend on the wavelength of the idler photon; however, because the magnification depends on the two wavelengths, the resolution of a pair of point scatters on the object depends on the wavelength of both photons. In cases in which the position of the object can be controlled, the minimum resolvable distance can be optimized. In the case in which the object is in the far field, the resolution depends only on the signal wavelength. In the second case, the Airy disk depends on the wavelength of both photons but the resolution depends on the signal photon. While the ghost imaging system has flexibility for certain applications, the resolution of the nondegenerate ghost imaging system does not offer improvement over the classical illumination of the object.

Physical Review A•Sep 29, 2008•55 citations

Quantum sensor using two-color ghost imaging technology

Sanjit Karmakar, Yanhua H. Shih

This article reports an experimental study on two-color ghost imaging with enhanced resolving power either by means of greater field of view or by means of greater imaging amplification compared with that of classical imaging.

Frontiers in Optics•Jan 1, 2010•0 citations

Photon-sparse microscopy: visible light imaging using infrared illumination

Reuben S. Aspden, Nathan R. Gemmell, Peter A. Morris +10 more

Conventional imaging systems rely upon illumination light that is scattered or transmitted by the object and subsequently imaged. Ghost-imaging systems based on parametric down-conversion use twin beams of position-correlated signal and idler photons. One beam illuminates an object while the image information is recovered from a second beam that has never interacted with the object. In this Letter, we report on a camera-based ghost imaging system where the correlated photons have significantly different wavelengths. Infrared photons at 1550 nm wavelength illuminate the object and are detected by an InGaAs/InP single-photon avalanche diode. The image data are recorded from the coincidently detected, position-correlated, visible photons at a wavelength of 460 nm using a highly efficient, low-noise, photon-counting camera. The efficient transfer of the image information from infrared illumination to visible detection wavelengths and the ability to count single photons allows the acquisition of an image while illuminating the object with an optical power density of only 100??pJ?cm-2?s-1. This wavelength-transforming ghost-imaging technique has potential for the imaging of light-sensitive specimens or where covert operation is desired.

Optica•Dec 10, 2015•178 citations

Ghost imaging with entanglement swapped photons

Andrew Forbes

The International Commission for Optics•May 16, 2017•0 citations

Quantum ghost imaging

Morris, Peter A.

The process of image recording is arguably one of the most prevalent technology in modern society and continues to inspire vast swathes of research due to its widespread applications spanning military, medical and consumer spheres. The danger present in a field so broad is that separate niches of research can become isolated with critical advancements struggling to traverse the gulfs between. Unifying the field is the omnipresent drive to acquire an ever increasing quality of images at the lowest possible cost, a goal which warrants continual fundamental research. Quantum entanglement exhibits many intriguing characteristics which make it a suitable tool for such fundamental investigations. The process of spontaneous parametric down- conversion has offered a yet unbeaten strength of photon correlations with the quantum nature of their production providing a reliable and controllable source of single-photons. Arising from these attributes is the technique known as ghost imaging. Though now known to be classically possible, the strength of entanglement generated correlations is yet to be surpassed. This thesis implemented this technique in tandem with the cutting edge detector technology in order to probe the fundamentals of image formation. This form of imaging allowed us to subject an object to a known number of photons whilst acquiring structural information from spatially separate, correlated photons which never interact with the object. The strength of the produced correlations allow us to acquire low background, high resolution images with far less light than traditional techniques and affords many novel benefits. The possibility of incorporating this technique with pre-existent regimes allowed me to draw from advancements made across the landscape of imaging research. Although referred to as “quantum ghost imaging” throughout this work, it should be noted that the intrinsic quantum nature of the correlations was not directly relied upon but provided an ideal source of strongly correlated photons. In order to determine the limits of a traditional imaging system this thesis first sought to answer the question: “can an image of an object be reconstructed from fewer photons than ii pixels in the image?” In chapter 3 I approached this from the perspective of compression, which minimises redundant information within a signal. This lead to the development of an imaging regime capable of imaging with far fewer photons than pixels in the image. By employing assumptions about the sparsity of natural images I was able to reconstruct an image of a biological sample containing an average of less than one photon per image pixel. Having reduced the number of photons necessary to form an image I then considered alternative methods for reducing the optical energy impinging on a sample. I sought to answer the question: “can non-degenerate ghost imaging reduce the optical energy impinged upon an object during imaging”. The photons produced in SPDC need not be of similar wavelengths, however may be chosen far from degeneracy, i.e. non-degenerate. In Chapter 4 I presented a ghost imaging system which illuminated the object with infrared light whilst recording the structural information via entangled visible photons. This allowed for objects opaque to visible light to be imaged in high quality without the need for a spatially resolving infrared detector, the state of the art of which lags behind their silicon based visible counterparts. I presented the systems capabilities by imaging objects which were etched into a gold substrate layered on to silicon, both of which are opaque to visible light. Not only did a reduction in energy deposition arise from the lower energy probe wavelength but applying the reconstruction techniques from the previous chapter brought that down to as low as ≈16 nJcm−2s−1. Seeking to expand the repertoire of applications, the low-light capabilities of my ghost imaging were applied to the technique of phase-contrast microscopy in chapter 5. Typically applied to translucent objects, phase-contrast imaging transfers phase information, i.e. the refractive index changed within the object, into an intensity distribution through the use of a phase-filter. In many of these applications the objects tend to be biological in nature, where high optical exposure can result in bleaching or damage. By applying the phase-filter non- locally, i.e. to the photons correlated to those probing the object, I acquired edge-enhanced images of a phase object whilst illuminating with significantly fewer photons than standard phase-contrast techniques. Having displayed the broad applicability of our low-light ghost imaging system, I then sought to determine the optical resolution in chapter 6. The resolution limits of ghost imaging are not clear at first glance owing to the resolutions dependence upon the strength of spatial correlations. As the length over which the spatial correlations are produced can be brought below the standard diffraction limit, it would seem the resolution of the system could be brought similarly low. To clarify this I artificially restricted the number of spatial modes in each of the correlated beams to uncover the physically realisable resolution. I show that although the resolution of a ghost imaging system to be fundamentally determined by the strength of the correlations, this can never be reached due to the inherent limitations of the intervening imaging system.

•Jan 1, 2018•0 citations

Ghost imaging with multipartite entangled quantum light states

A. S. Chirkin

•Jan 1, 2016•0 citations
We examine the resolution of a ghost imaging system for the case in which the entangled photons are nondegenerate in frequency. The signal photon illuminates the object and is detected by a bucket detector. The idler photon is detected by a point detector. We consider the two cases in which the imaging lens is in the same arm as the object and when it is in the other arm. In the first case, the Airy disk is shown to depend on the wavelength of the idler photon; however, because the magnification depends on the two wavelengths, the resolution of a pair of point scatters on the object depends on the wavelength of both photons. In cases in which the position of the object can be controlled, the minimum resolvable distance can be optimized. In the case in which the object is in the far field, the resolution depends only on the signal wavelength. In the second case, the Airy disk depends on the wavelength of both photons but the resolution depends on the signal photon. While the ghost imaging system has flexibility for certain applications, the resolution of the nondegenerate ghost imaging system does not offer improvement over the classical illumination of the object.
Conventional imaging systems rely upon illumination light that is scattered or transmitted by the object and subsequently imaged. Ghost-imaging systems based on parametric down-conversion use twin beams of position-correlated signal and idler photons. One beam illuminates an object while the image information is recovered from a second beam that has never interacted with the object. In this Letter, we report on a camera-based ghost imaging system where the correlated photons have significantly different wavelengths. Infrared photons at 1550 nm wavelength illuminate the object and are detected by an InGaAs/InP single-photon avalanche diode. The image data are recorded from the coincidently detected, position-correlated, visible photons at a wavelength of 460 nm using a highly efficient, low-noise, photon-counting camera. The efficient transfer of the image information from infrared illumination to visible detection wavelengths and the ability to count single photons allows the acquisition of an image while illuminating the object with an optical power density of only 100??pJ?cm-2?s-1. This wavelength-transforming ghost-imaging technique has potential for the imaging of light-sensitive specimens or where covert operation is desired.
The process of image recording is arguably one of the most prevalent technology in modern society and continues to inspire vast swathes of research due to its widespread applications spanning military, medical and consumer spheres. The danger present in a field so broad is that separate niches of research can become isolated with critical advancements struggling to traverse the gulfs between. Unifying the field is the omnipresent drive to acquire an ever increasing quality of images at the lowest possible cost, a goal which warrants continual fundamental research. Quantum entanglement exhibits many intriguing characteristics which make it a suitable tool for such fundamental investigations. The process of spontaneous parametric down- conversion has offered a yet unbeaten strength of photon correlations with the quantum nature of their production providing a reliable and controllable source of single-photons. Arising from these attributes is the technique known as ghost imaging. Though now known to be classically possible, the strength of entanglement generated correlations is yet to be surpassed. This thesis implemented this technique in tandem with the cutting edge detector technology in order to probe the fundamentals of image formation. This form of imaging allowed us to subject an object to a known number of photons whilst acquiring structural information from spatially separate, correlated photons which never interact with the object. The strength of the produced correlations allow us to acquire low background, high resolution images with far less light than traditional techniques and affords many novel benefits. The possibility of incorporating this technique with pre-existent regimes allowed me to draw from advancements made across the landscape of imaging research. Although referred to as “quantum ghost imaging” throughout this work, it should be noted that the intrinsic quantum nature of the correlations was not directly relied upon but provided an ideal source of strongly correlated photons. In order to determine the limits of a traditional imaging system this thesis first sought to answer the question: “can an image of an object be reconstructed from fewer photons than ii pixels in the image?” In chapter 3 I approached this from the perspective of compression, which minimises redundant information within a signal. This lead to the development of an imaging regime capable of imaging with far fewer photons than pixels in the image. By employing assumptions about the sparsity of natural images I was able to reconstruct an image of a biological sample containing an average of less than one photon per image pixel. Having reduced the number of photons necessary to form an image I then considered alternative methods for reducing the optical energy impinging on a sample. I sought to answer the question: “can non-degenerate ghost imaging reduce the optical energy impinged upon an object during imaging”. The photons produced in SPDC need not be of similar wavelengths, however may be chosen far from degeneracy, i.e. non-degenerate. In Chapter 4 I presented a ghost imaging system which illuminated the object with infrared light whilst recording the structural information via entangled visible photons. This allowed for objects opaque to visible light to be imaged in high quality without the need for a spatially resolving infrared detector, the state of the art of which lags behind their silicon based visible counterparts. I presented the systems capabilities by imaging objects which were etched into a gold substrate layered on to silicon, both of which are opaque to visible light. Not only did a reduction in energy deposition arise from the lower energy probe wavelength but applying the reconstruction techniques from the previous chapter brought that down to as low as ≈16 nJcm−2s−1. Seeking to expand the repertoire of applications, the low-light capabilities of my ghost imaging were applied to the technique of phase-contrast microscopy in chapter 5. Typically applied to translucent objects, phase-contrast imaging transfers phase information, i.e. the refractive index changed within the object, into an intensity distribution through the use of a phase-filter. In many of these applications the objects tend to be biological in nature, where high optical exposure can result in bleaching or damage. By applying the phase-filter non- locally, i.e. to the photons correlated to those probing the object, I acquired edge-enhanced images of a phase object whilst illuminating with significantly fewer photons than standard phase-contrast techniques. Having displayed the broad applicability of our low-light ghost imaging system, I then sought to determine the optical resolution in chapter 6. The resolution limits of ghost imaging are not clear at first glance owing to the resolutions dependence upon the strength of spatial correlations. As the length over which the spatial correlations are produced can be brought below the standard diffraction limit, it would seem the resolution of the system could be brought similarly low. To clarify this I artificially restricted the number of spatial modes in each of the correlated beams to uncover the physically realisable resolution. I show that although the resolution of a ghost imaging system to be fundamentally determined by the strength of the correlations, this can never be reached due to the inherent limitations of the intervening imaging system.