Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Correlated imaging: classical noise vs. quantum entanglement

Luigi A. Lugiato, A. Gatti, E. Brambilla, Morten Bache

Published May 25, 2004• 3 citations
Publisher

Abstract

We analytically show that it is possible to perform coherent imaging by using the classical correlation of two beams obtained by splitting incoherent thermal radiation. The case of such two classically correlated beams is treated in parallel with the configuration based on two entangled beams produced by parametric down-conversion, and a basic analogy is pointed out. The results are compared in a specific numerical example.

DOI
10.1117/12.544961

Related papers

Correlated imaging, quantum and classical

A. Gatti, E. Brambilla, Morten Bache +1 more

We analytically show that it is possible to perform coherent imaging by using the classical correlation of two beams obtained by splitting incoherent thermal radiation. A formal analogy is demonstrated between two such classically correlated beams and two entangled beams produced by parametric down-conversion. Because of this analogy, the classical beams can mimic qualitatively all the imaging properties of the entangled beams, even in ways which up to now were not believed possible. A key feature is that these classical beams are spatially correlated both in the near field and in the far field. Using realistic numerical simulations the performances of a quasithermal and a parametric down-conversion source are shown to be closely similar, both for what concerns the resolution and statistical properties. The results of this paper provide a scenario for the discussion of what role the entanglement plays in correlated imaging.

Physical Review A•Jul 6, 2004•414 citations

Ghost Imaging with Thermal Light: Comparing Entanglement and ClassicalCorrelation

A. Gatti, E. Brambilla, Morten Bache +1 more

We consider a scheme for coherent imaging that exploits the classical correlation of two beams obtained by splitting incoherent thermal radiation. This case is analyzed in parallel with the configuration based on two entangled beams produced by parametric down-conversion, and a precise formal analogy is pointed out. This analogy opens the possibility of using classical beams from thermal radiation for ghost imaging schemes in the same way as entangled beams.

arXiv:quant-ph/0307187•Physical Review Letters•Aug 26, 2004•1,017 citations

Ghost imaging, quantum and classical aspects

A. Gatti, E. Brambilla, Morten Bache +1 more

We analytically show that it is possible to perform coherent imaging by using the classical correlation of two beams obtained by splitting incoherent thermal radiation. A formal analogy is demonstrated between two such classically correlated beams and two entangled beams produced by parametric down-conversion. Because of this analogy, the classical beams can mimic qualitatively all the imaging properties of the entangled beams, even in ways which up to now were not believed possible. A key feature is that these classical beams are spatially correlated both in the near-field and in the far-field. Using realistic numerical simulations the performances of a quasi-thermal and a parametric down-conversion source are shown to be closely similar, both for what concerns the resolution and statistical properties. The results of this paper provide a new scenario for the discussion of what role the entanglement plays in correlated imaging.

arXiv:quant-ph/0405056•May 11, 2004•5 citations

Correlated imaging with macroscopic fields

E. Brambilla, A. Gatti, Morten Bache +1 more

We demonstrate analytically that correlated imaging in the regime of large photon number can be implemented using both a classical and an entangled source. The classically correlated beams are obtained by dividing thermal radiation by a beam splitter while entangled beams are obtained through parametric down‐conversion. By treating the two system in parallel, a formal analogy is outlined between the two cases showing that classical beams can mimic qualitatively all the imaging features of the entangled beams. We also propose a method to improve substantially the imaging performances of correlated imaging which is based on homodyne detection combined with spatial averages.

Fortschritte der Physik•Oct 11, 2004•6 citations

Experimental Sub-shot Noise Quantum Imaging versus Differential Classical Imaging

G. Brida, Marco Genovese, E. Monticone +3 more

Sub-Shot Noise quantum imaging is a novel quantum method allowing in principle to recover the image of a weak absorbing object, even if illuminated by a low photon flux, with a signal to noise ratio larger than classical imaging techniques. Here we present the first realization of a genuine quantum imaging schemes exploiting correlation of twin beams produced by Parametric Down conversion. We compare its performances with respect to the corresponding classical scheme, showing a clear improvement of the sensitivity in the reconstruction of the absorbtion profile of a weak object.

International Conference on Quantum, Nano and Micro Technologies (ICQNM)•Feb 1, 2010•3 citations

Beating classical imaging limits with entangled photons

Ermes Toninelli, Thomas Gregory, Paul‐Antoine Moreau +1 more

How can quantum mechanics deliver better imaging performance? Parametric down-conversion sources produce pairs of photons that are correlated in many degrees of freedom, including their spatial positions. By using a camera to detect these pairs of photons it is possible configure imaging systems that can either beat the classical resolution limit or the classical noise limit. We demonstrate how a simple down-conversion source based on a laser and non-linear crystal can be combined with an EMCCD camera to achieve either of these outcomes. Firstly, when both photons pass through the sample, we show a full-field, resolution-enhancing scheme, based on the centroid estimation of the photon pairs. By optimising the software control of the EMCCD camera running in the photon-sparse regime we achieve a resolution enhancement over the equivalent classical limit. Secondly, we show a similar scheme but where only one of the two photons pass through the sample and the other acts as a reference, in this case the ratio of the two resulting images eliminates the background noise of the camera, and background light, achieving an increase in image contrast.

Optical and Quantum Sensing and Precision Metrology II•Mar 1, 2019•8 citations
We analytically show that it is possible to perform coherent imaging by using the classical correlation of two beams obtained by splitting incoherent thermal radiation. The case of such two classically correlated beams is treated in parallel with the configuration based on two entangled beams produced by parametric down-conversion, and a basic analogy is pointed out. The results are compared in a specific numerical example.
We analytically show that it is possible to perform coherent imaging by using the classical correlation of two beams obtained by splitting incoherent thermal radiation. A formal analogy is demonstrated between two such classically correlated beams and two entangled beams produced by parametric down-conversion. Because of this analogy, the classical beams can mimic qualitatively all the imaging properties of the entangled beams, even in ways which up to now were not believed possible. A key feature is that these classical beams are spatially correlated both in the near field and in the far field. Using realistic numerical simulations the performances of a quasithermal and a parametric down-conversion source are shown to be closely similar, both for what concerns the resolution and statistical properties. The results of this paper provide a scenario for the discussion of what role the entanglement plays in correlated imaging.
We analytically show that it is possible to perform coherent imaging by using the classical correlation of two beams obtained by splitting incoherent thermal radiation. A formal analogy is demonstrated between two such classically correlated beams and two entangled beams produced by parametric down-conversion. Because of this analogy, the classical beams can mimic qualitatively all the imaging properties of the entangled beams, even in ways which up to now were not believed possible. A key feature is that these classical beams are spatially correlated both in the near-field and in the far-field. Using realistic numerical simulations the performances of a quasi-thermal and a parametric down-conversion source are shown to be closely similar, both for what concerns the resolution and statistical properties. The results of this paper provide a new scenario for the discussion of what role the entanglement plays in correlated imaging.
We demonstrate analytically that correlated imaging in the regime of large photon number can be implemented using both a classical and an entangled source. The classically correlated beams are obtained by dividing thermal radiation by a beam splitter while entangled beams are obtained through parametric down‐conversion. By treating the two system in parallel, a formal analogy is outlined between the two cases showing that classical beams can mimic qualitatively all the imaging features of the entangled beams. We also propose a method to improve substantially the imaging performances of correlated imaging which is based on homodyne detection combined with spatial averages.
Sub-Shot Noise quantum imaging is a novel quantum method allowing in principle to recover the image of a weak absorbing object, even if illuminated by a low photon flux, with a signal to noise ratio larger than classical imaging techniques. Here we present the first realization of a genuine quantum imaging schemes exploiting correlation of twin beams produced by Parametric Down conversion. We compare its performances with respect to the corresponding classical scheme, showing a clear improvement of the sensitivity in the reconstruction of the absorbtion profile of a weak object.
How can quantum mechanics deliver better imaging performance? Parametric down-conversion sources produce pairs of photons that are correlated in many degrees of freedom, including their spatial positions. By using a camera to detect these pairs of photons it is possible configure imaging systems that can either beat the classical resolution limit or the classical noise limit. We demonstrate how a simple down-conversion source based on a laser and non-linear crystal can be combined with an EMCCD camera to achieve either of these outcomes. Firstly, when both photons pass through the sample, we show a full-field, resolution-enhancing scheme, based on the centroid estimation of the photon pairs. By optimising the software control of the EMCCD camera running in the photon-sparse regime we achieve a resolution enhancement over the equivalent classical limit. Secondly, we show a similar scheme but where only one of the two photons pass through the sample and the other acts as a reference, in this case the ratio of the two resulting images eliminates the background noise of the camera, and background light, achieving an increase in image contrast.