Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Applied Spectroscopy

Fluorescent detection of narrow absorption lines in intracavity atomic spectroscopy

Viktor S. Burakov, P. Ya. Misakov, P. A. Naumenkov, S. V. Nechaev, С. Н. Райков

Published Mar 1, 1978• 1 citation
Publisher
DOI
10.1007/bf00615426

Related papers

Theory of intracavity absorption spectroscopy

W. Brunner, Henryk Paul

Optical and Quantum Electronics•Mar 1, 1978•28 citations

Saturation effects in the sub-Doppler spectroscopy of cesium vapor confined in an extremely thin cell

C. Andreeva, S. Cartaleva, L. Petrov +5 more

Saturation effects affecting absorption and fluorescence spectra of an atomic vapor confined in an extremely thin cell (cell thickness $L<1\phantom{\rule{0.3em}{0ex}}\ensuremath{\mu}\mathrm{m}$) are investigated experimentally and theoretically. The study is performed on the ${D}_{2}$ line $(\ensuremath{\lambda}=852\phantom{\rule{0.3em}{0ex}}\mathrm{nm})$ of Cs and concentrates on the two situations $L=\ensuremath{\lambda}∕2$ and $L=\ensuremath{\lambda}$, the most contrasted ones with respect to the length dependence of the coherent Dicke narrowing. For $L=\ensuremath{\lambda}∕2$, the Dicke-narrowed absorption profile simply broadens and saturates in amplitude when increasing the light intensity, while for $L=\ensuremath{\lambda}$, sub-Doppler dips of reduced absorption at the line-center appear on the broad absorption profile. For a fluorescence detection at $L=\ensuremath{\lambda}$, saturation induces narrow dips, but only for hyperfine components undergoing a population loss through optical pumping. These experimental results are interpreted with the help of the various existing models and are compared with numerical calculations based upon a two-level modeling that considers both a closed and an open system.

arXiv:0706.0837•Physical Review A•Jul 31, 2007•60 citations

High-resolution spectroscopy of weakly absorbing objects based on a competing beam method

Sergei A. Batishche, Vasili A. Mostovnikov, Anatolii N Rubinov

A new competing beam method is proposed for intracavity measurement of weak absorption. In this method two independent lasers with the same active medium are employed. An investigated sample is placed inside the resonator of one of the lasers with a narrow tunable emission line. In contrast to the selective intracavity absorption method, photoelectric recording of the spectra can be used in the proposed method and this can be done for narrow lines as well as for wide absorption bands. Moreover, the new method can be used to determine the two-photon absorption spectra.

Soviet Journal of Quantum Electronics•Nov 30, 1976•3 citations

Detection of spectrally narrow light emission by laser intra-cavity spectroscopy

Valery M. Baev, Klaus J. Boller, A. Weiler +1 more

Optics Communications•Jun 1, 1987•10 citations

Intracavity atomic beam laser spectrometer for low intensity spectral lines

Frank N. Trager, Ronny Neumann, J. Kowalski +1 more

Applied Physics A•Jan 1, 1977•15 citations

Shelving spectroscopy of the strontium intercombination line

Isam Manai, Molineri, A, Fréjaville, C +8 more

We present a spectroscopy scheme for the 7-kHz-wide 689-nm intercombination line of strontium. We rely on shelving detection, where electrons are first excited to a metastable state by the spectroscopy laser before their state is probed using the broad transition at 461 nm. As in the similar setting of calcium beam clocks, this enhances dramatically the signal strength as compared to direct saturated fluorescence or absorption spectroscopy of the narrow line. We implement shelving spectroscopy both in directed atomic beams and hot vapor cells with isotropic atomic velocities. We measure a fractional frequency instability $\sim 2 \times 10^{-12}$ at 1 s limited by technical noise - about one order of magnitude above shot noise limitations for our experimental parameters. Our work illustrates the robustness and flexibility of a scheme that can be very easily implemented in the reference cells or ovens of most existing strontium experiments, and may find applications for low-complexity clocks.

•Oct 25, 2019•3 citations
Saturation effects affecting absorption and fluorescence spectra of an atomic vapor confined in an extremely thin cell (cell thickness $L<1\phantom{\rule{0.3em}{0ex}}\ensuremath{\mu}\mathrm{m}$) are investigated experimentally and theoretically. The study is performed on the D2{D}_{2}D2​ line $(\ensuremath{\lambda}=852\phantom{\rule{0.3em}{0ex}}\mathrm{nm})$ of Cs and concentrates on the two situations $L=\ensuremath{\lambda}∕2$ and $L=\ensuremath{\lambda}$, the most contrasted ones with respect to the length dependence of the coherent Dicke narrowing. For $L=\ensuremath{\lambda}∕2$, the Dicke-narrowed absorption profile simply broadens and saturates in amplitude when increasing the light intensity, while for $L=\ensuremath{\lambda}$, sub-Doppler dips of reduced absorption at the line-center appear on the broad absorption profile. For a fluorescence detection at $L=\ensuremath{\lambda}$, saturation induces narrow dips, but only for hyperfine components undergoing a population loss through optical pumping. These experimental results are interpreted with the help of the various existing models and are compared with numerical calculations based upon a two-level modeling that considers both a closed and an open system.
A new competing beam method is proposed for intracavity measurement of weak absorption. In this method two independent lasers with the same active medium are employed. An investigated sample is placed inside the resonator of one of the lasers with a narrow tunable emission line. In contrast to the selective intracavity absorption method, photoelectric recording of the spectra can be used in the proposed method and this can be done for narrow lines as well as for wide absorption bands. Moreover, the new method can be used to determine the two-photon absorption spectra.
We present a spectroscopy scheme for the 7-kHz-wide 689-nm intercombination line of strontium. We rely on shelving detection, where electrons are first excited to a metastable state by the spectroscopy laser before their state is probed using the broad transition at 461 nm. As in the similar setting of calcium beam clocks, this enhances dramatically the signal strength as compared to direct saturated fluorescence or absorption spectroscopy of the narrow line. We implement shelving spectroscopy both in directed atomic beams and hot vapor cells with isotropic atomic velocities. We measure a fractional frequency instability ∼2×10−12\sim 2 \times 10^{-12}∼2×10−12 at 1 s limited by technical noise - about one order of magnitude above shot noise limitations for our experimental parameters. Our work illustrates the robustness and flexibility of a scheme that can be very easily implemented in the reference cells or ovens of most existing strontium experiments, and may find applications for low-complexity clocks.