Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum-Light-Enhanced Optical Magnetometry

Florian Wolfgramm, Alessandro Ceré, Yannick A. de Icaza Astiz, Federica A. Beduini, Ana Predojević, Marco Koschorreck, Morgan W. Mitchell

Published Jan 1, 2011• 0 citations
Publisher

Abstract

We demonstrate a light-shot-noise limited magnetometer based on the Faraday effect in a hot unpolarized ensemble of rubidium atoms. By using off-resonant, polarization-squeezed probe light, we improve the sensitivity of the magnetometer by 3.2 dB.
DOI
10.1364/qels.2011.qtuj1

Related papers

Squeezed-Light Optical Magnetometry

Florian Wolfgramm, Alessandro Ceré, Federica A. Beduini +3 more

We demonstrate a light-shot-noise-limited magnetometer based on the Faraday effect in a hot unpolarized ensemble of rubidium atoms. By using off-resonant, polarization-squeezed probe light, we improve the sensitivity of the magnetometer by 3.2 dB. The technique could improve the sensitivity of the most advanced magnetometers and quantum nondemolition measurements of atomic spin ensembles.

arXiv:1008.1721•Physical Review Letters•Jul 29, 2010•240 citations

Squeezed-light enhancement of sensitivity and signal bandwidth in an optically-pumped magnetometer

Charikleia Troullinou, Ricardo Jiménez-Martínez, Jia Kong +2 more

We study the effect of optical squeezing on the performance of a sensitive, quantum-noise-limited optically-pumped magnetometer. We use Bell-Bloom optical pumping to excite a $^{87}$Rb vapor and Faraday rotation to detect spin precession. The sub-$\mathrm{pT}/\sqrt{\mathrm{Hz}}$ sensitivity is limited by spin projection noise (photon shot noise) at low (high) frequencies. Probe polarization squeezing both improves high-frequency sensitivity and increases signal bandwidth. The accompanying polarization anti-squeezing perturbs only an unmeasured spin component, so there is no loss of sensitivity at any frequency. The method is compatible with high-density and multi-pass techniques that reach extreme sensitivity.

•Aug 3, 2021•0 citations

Experimental light-squeezing-enhanced magnetometry

Alessandro Ceré, Florian Wolfgramm, Federica A. Beduini +3 more

The ability to measure magnetic fields with high sensitivity is a key requirement in many physical, biological and medical applications. Currently the most sensitive magnetometers are optical magnetometers, in which the polarization of an atomic sample responds to the field and is read out by an optical measurement. These instruments are limited by two fundamental sources of quantum noise: projection noise of the atoms and shot noise of the light. For magnetometers designed to have a high statistical sensitivity, contributions from both sources are comparable. Here we show that the sensitivity can be improved by the application of non-classical light.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•May 1, 2011•0 citations

Quantum metrology with cold atomic ensembles

Morgan W. Mitchell, R. J. Sewell, M. Napolitano +4 more

Quantum metrology uses quantum features such as entanglement and squeezing to improve the sensitivity of quantum-limited measurements. Long established as a valuable technique in optical measurements such as gravitational-wave detection, quantum metrology is increasingly being applied to atomic instruments such as matter-wave interferometers, atomic clocks, and atomic magnetometers. Several of these new applications involve dual optical/atomic quantum systems, presenting both new challenges and new opportunities. Here we describe an optical magnetometry system that achieves both shot-noise-limited and projection-noise-limited performance, allowing study of optical magnetometry in a fully-quantum regime [1]. By near-resonant Faraday rotation probing, we demonstrate measurement-based spin squeezing in a magnetically-sensitive atomic ensemble [2-4]. The versatility of this system allows us also to design metrologically-relevant optical nonlinearities, and to perform quantum-noise-limited measurements with interacting photons. As a first interaction-based measurement [5], we implement a non-linear metrology scheme proposed by Boixo et al. with the surprising feature of precision scaling better than the 1/N “Heisenberg limit” [6].

EPJ Web of Conferences•Jan 1, 2013•1 citation

Quantum-enhanced magnetometer with low-frequency squeezing

Travis Horrom, Robinjeet Singh, Jonathan P. Dowling +1 more

We report the demonstration of a magnetometer with noise-floor reduction below the shot-noise level. This magnetometer, based on a nonlinear magneto-optical rotation effect, is enhanced by the injection of a squeezed vacuum state into its input. The noise spectrum shows squeezed noise reduction of about $2\ifmmode\pm\else\textpm\fi{}0.35$ dB spanning from close to 100 Hz to several megahertz. We also report on the observation of two different regimes of operation of such a magnetometer: one in which the detection noise is limited by the quantum noise of the light probe only, and one in which we see additional noise originating from laser noise which is rotated into the vacuum polarization.

arXiv:1202.3831•Physical Review A•Aug 3, 2012•91 citations

Quantum-enhanced rubidium atomic magnetometer based on Faraday rotation via 795 nm stokes operator squeezed light

Lele Bai, Xin Wen, Yu-Lin Yang +4 more

Abstract With the help of Stokes operator Ŝ 2 squeezed state (also called polarization squeezed state (PSS)) of 795 nm light, rubidium-87 ( 87 Rb) atomic magnetometer based on Faraday rotation (FR) has been implemented and characterized. The PSS of Stokes operator Ŝ 2 of 795 nm light has been prepared by means of coherently combining the polarization coherent state (PCS) of a linearly p-polarized bright 795 nm light beam and a linearly s-polarized squeezed vacuum state (SVS) generated by a 397.5 nm ultraviolet laser pumped sub-threshold optical parametric oscillator (OPO) with a PPKTP bulk crystal inside the OPO cavity. PSS with a squeezing level of −3.7 ± 0.3 dB has been achieved around the analysis frequency of 10 kHz. At different transitions of D 1 line, various frequency detuning, and reasonable atomic vapor cell’s temperature, FR has been measured and compared. To decrease absorption (scattering) losses and the back-action from atomic spin noise to the probe beam’s polarization noise for maintaining the quantum properties of PSS of Stokes operator Ŝ 2 of 795 nm light, we had to run our magnetometer with 87 Rb vapor cell’s temperature below 60 °C, at which the PSS was almost destroyed. The sensitivities of magnetic field measurement were characterized via measuring signal-to-noise ratio of the alternating current calibrated magnetic field signal with a balanced polarimeter. Under the conditions of the atomic number density of ∼5.8 × 10 10 cm −3 ( T ∼ 40 °C) and the probe beam with a detuning of ∼−400 MHz relative to the 5S 1/2 ( F g = 2) − 5P 1/2 ( F e = 1) transition of 87 Rb D 1 line, a typical sensitivity of ∼19.5 pT (Hz 1/2 ) −1 has been achieved employing PSS of Stokes operator Ŝ 2 as the probe, compared with a sensitivity of ∼28.3pT (Hz 1/2 ) −1 using PCS as the probe. We preliminarily demonstrated that the quantum-enhanced sensitivity in a Faraday-rotation-based 87 Rb atomic magnetometer with the help of PSS of 795 nm light.

arXiv:2112.00186•Journal of Optics•Aug 1, 2021•28 citations
We study the effect of optical squeezing on the performance of a sensitive, quantum-noise-limited optically-pumped magnetometer. We use Bell-Bloom optical pumping to excite a 87^{87}87Rb vapor and Faraday rotation to detect spin precession. The sub-pT/Hz\mathrm{pT}/\sqrt{\mathrm{Hz}}pT/Hz​ sensitivity is limited by spin projection noise (photon shot noise) at low (high) frequencies. Probe polarization squeezing both improves high-frequency sensitivity and increases signal bandwidth. The accompanying polarization anti-squeezing perturbs only an unmeasured spin component, so there is no loss of sensitivity at any frequency. The method is compatible with high-density and multi-pass techniques that reach extreme sensitivity.
The ability to measure magnetic fields with high sensitivity is a key requirement in many physical, biological and medical applications. Currently the most sensitive magnetometers are optical magnetometers, in which the polarization of an atomic sample responds to the field and is read out by an optical measurement. These instruments are limited by two fundamental sources of quantum noise: projection noise of the atoms and shot noise of the light. For magnetometers designed to have a high statistical sensitivity, contributions from both sources are comparable. Here we show that the sensitivity can be improved by the application of non-classical light.
Quantum metrology uses quantum features such as entanglement and squeezing to improve the sensitivity of quantum-limited measurements. Long established as a valuable technique in optical measurements such as gravitational-wave detection, quantum metrology is increasingly being applied to atomic instruments such as matter-wave interferometers, atomic clocks, and atomic magnetometers. Several of these new applications involve dual optical/atomic quantum systems, presenting both new challenges and new opportunities. Here we describe an optical magnetometry system that achieves both shot-noise-limited and projection-noise-limited performance, allowing study of optical magnetometry in a fully-quantum regime [1]. By near-resonant Faraday rotation probing, we demonstrate measurement-based spin squeezing in a magnetically-sensitive atomic ensemble [2-4]. The versatility of this system allows us also to design metrologically-relevant optical nonlinearities, and to perform quantum-noise-limited measurements with interacting photons. As a first interaction-based measurement [5], we implement a non-linear metrology scheme proposed by Boixo et al. with the surprising feature of precision scaling better than the 1/N “Heisenberg limit” [6].
We report the demonstration of a magnetometer with noise-floor reduction below the shot-noise level. This magnetometer, based on a nonlinear magneto-optical rotation effect, is enhanced by the injection of a squeezed vacuum state into its input. The noise spectrum shows squeezed noise reduction of about $2\ifmmode\pm\else\textpm\fi{}0.35$ dB spanning from close to 100 Hz to several megahertz. We also report on the observation of two different regimes of operation of such a magnetometer: one in which the detection noise is limited by the quantum noise of the light probe only, and one in which we see additional noise originating from laser noise which is rotated into the vacuum polarization.
Abstract With the help of Stokes operator Ŝ 2 squeezed state (also called polarization squeezed state (PSS)) of 795 nm light, rubidium-87 ( 87 Rb) atomic magnetometer based on Faraday rotation (FR) has been implemented and characterized. The PSS of Stokes operator Ŝ 2 of 795 nm light has been prepared by means of coherently combining the polarization coherent state (PCS) of a linearly p-polarized bright 795 nm light beam and a linearly s-polarized squeezed vacuum state (SVS) generated by a 397.5 nm ultraviolet laser pumped sub-threshold optical parametric oscillator (OPO) with a PPKTP bulk crystal inside the OPO cavity. PSS with a squeezing level of −3.7 ± 0.3 dB has been achieved around the analysis frequency of 10 kHz. At different transitions of D 1 line, various frequency detuning, and reasonable atomic vapor cell’s temperature, FR has been measured and compared. To decrease absorption (scattering) losses and the back-action from atomic spin noise to the probe beam’s polarization noise for maintaining the quantum properties of PSS of Stokes operator Ŝ 2 of 795 nm light, we had to run our magnetometer with 87 Rb vapor cell’s temperature below 60 °C, at which the PSS was almost destroyed. The sensitivities of magnetic field measurement were characterized via measuring signal-to-noise ratio of the alternating current calibrated magnetic field signal with a balanced polarimeter. Under the conditions of the atomic number density of ∼5.8 × 10 10 cm −3 ( T ∼ 40 °C) and the probe beam with a detuning of ∼−400 MHz relative to the 5S 1/2 ( F g = 2) − 5P 1/2 ( F e = 1) transition of 87 Rb D 1 line, a typical sensitivity of ∼19.5 pT (Hz 1/2 ) −1 has been achieved employing PSS of Stokes operator Ŝ 2 as the probe, compared with a sensitivity of ∼28.3pT (Hz 1/2 ) −1 using PCS as the probe. We preliminarily demonstrated that the quantum-enhanced sensitivity in a Faraday-rotation-based 87 Rb atomic magnetometer with the help of PSS of 795 nm light.