Characteristics and operating conditions of an atomic Mach-Zehnder interferometer are discussed. It is shown that a laser-cooled ultracold atomic source and detection of interference by spatially resolved detector greatly improve the performance of the atomic interferometer.
We demonstrate an atom interferometer that uses a laser-cooled continuous beam of 87Rb atoms having velocities of 10–20 m/s. With spatially separated Raman beams to coherently manipulate the atomic wave packets, Mach–Zehnder interference fringes are observed at an interference distance of 2L = 19 mm. The apparatus operates within a small enclosed area of 0.07 mm2 at a bandwidth of 190 Hz with a deduced sensitivity of 7.8×10−5 rad/s/Hz for rotations. Using a low-velocity continuous atomic source in an atom interferometer enables high sampling rates and bandwidths without sacrificing sensitivity and compactness, which are important for applications in real dynamic environments.
Four laser beams traveling in the same direction that split and reflect a thermal calcium atomic beam compose an atomic interferometer like the Mach-Zehnder optical interferometer. The interference performance of the atomic interferometer was examined by changing the phase of the induced dipole moment in the atomic wave due to the laser beams, or the phase of atomic ``wavepacket'' in an atomic trajectory due to the ac Stark effect. An interference signal with a visibility of more than 15% was obtained. This interferometer will be useful in the detection of weak signals that require a long integration time, since it is less sensitive to the fluctuation of the laser frequency compared with the optical Ramsey atomic interferometer.
The role of source cloud spatial coherence in a Mach-Zehnder-type atom interferometer is experimentally investigated. The visibility and contrast of a Bose-Einstein condensate (BEC) and three thermal sources with varying spatial coherence are compared as a function of interferometer time. At short times, the fringe visibility of a BEC source approaches 100 nearly independent of $\ensuremath{\pi}$ pulse efficiency, while thermal sources have fringe visibilities limited to the $\ensuremath{\pi}$ pulse efficiency. More importantly for precision measurement systems, the BEC source maintains interference at interferometer times significantly beyond the thermal source.
The best performance of a Mach-Zehnder interferometer is achieved with the input state $\ensuremath{\mid}{N}_{T}∕2+1⟩\ensuremath{\mid}{N}_{T}∕2\ensuremath{-}1⟩+\ensuremath{\mid}{N}_{T}∕2\ensuremath{-}1⟩\ensuremath{\mid}{N}_{T}∕2+1⟩$, NT being the total number of atoms or photons. This gives (i) a phase-shift error confidence ${C}_{68%}=2.67∕{N}_{T}$ with (ii) a single interferometric measurement. Different input quantum states can achieve the Heisenberg scaling $\ensuremath{\sim}1∕{N}_{T}$ but with higher prefactors and at the price of a statistical analysis of two or more independent measurements.
We study the effect of quantum motion in a Mach-Zehnder interferometer where ultracold, two-level atoms cross a $\ensuremath{\pi}∕2\text{\ensuremath{-}}\ensuremath{\pi}\text{\ensuremath{-}}\ensuremath{\pi}∕2$ configuration of separated, laser illuminated regions. Explicit and exact expressions are obtained for transmission amplitudes of monochromatic, incident atomic waves using recurrence relations which take into account all possible paths: the direct ones usually considered in the simple semiclassical treatment, but including quantum motion corrections, and the paths in which the atoms are repeatedly reflected at the fields.
A new method for the detection of atomic spin precession based on the Mach-Zehnder interferometer (MZI) is proposed and experimentally demonstrated. Different from the conventional polarization detection methods which obtain the atomic spin precession signal by measuring the change of the probe laser power, the proposed method uses the laser modulated by an electro-optic phase modulator (EOM) as the source of the interferometer, and obtains the atomic spin precession signal by measuring the phase difference between the two arms of the MZI. The output of interferometer is independent of the probe laser power, which avoids the system error caused by the fluctuation of the probe laser power, and the long-term stability of the system is effectively improved. At the same time, the method adopts high-frequency electro-optic modulation, which can effectively suppress low-frequency noise, such as 1/f noise, and can significantly improve the detection sensitivity. The rotation sensitivity and long-term stability of the atomic comagnetometer were tested using the MZI detection method and a typical detection method, respectively. The comparison results show that the proposed method has the highest low frequency sensitivity and the potential to improve the long-term stability of the system.