Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Japanese Journal of Applied Physics

85Rb Coherent-Population-Trapping Atomic Clock with Low Power Consumption

Shigeyoshi Goka

Published Aug 20, 2009• 8 citations
Publisher

Abstract

In this paper, the investigation of a 85 Rb coherent-population-trapping (CPT) atomic clock for low-power operation is described. The modulation profiles and CPT resonances for both 85 Rb and 87 Rb, the long-term frequency stabilities of the CPT resonance for both, and the feasibility of switching between low-power and high-stability operation modes are presented. The choice of 85 Rb rather than conventional 87 Rb is dictated by the lower ground-state hyperfine-splitting frequency, which leads to less than one-half the required RF power and more effective RF-related circuit designs. CPT resonances for both 85 Rb and 87 Rb can be observed separately in the same natural mixture Rb gas cell, and the linewidth is less than 120 Hz in both cases. The long-term frequency stabilities are <4.0 ×10 -12 /day for 85 Rb and <3.5 ×10 -12 /day for 87 Rb. These results indicate that a 85 Rb CPT atomic clock has a long-term stability of ∼4.0 ×10 -12 /day and consumes about one-half the RF power of a 87 Rb equivqlent. In addition, it is possible to switch between low-power and high-stability operation modes by changing the RF frequency and power.

DOI
10.1143/jjap.48.082202

Related papers

85Rb D1-line CPT atomic clock with low power consumption

Shigeyoshi Goka

This paper describes the investigation of a85Rb D1-line coherent population trapping (CPT) atomic clock with a Rb gas-cell containing a natural mixture of Rb atoms and buffer gas. The choice of85Rb rather than conventional87Rb is dictated by the lower ground-state hyperfine-splitting frequency, which leads to less than one-half the required RF power and more effective RF-related circuit designs. In this paper, the modulation profiles, the CPT resonances, and the long-term frequency stabilities of the CPT resonance for85Rb D1 and D2 lines are presented. The frequency deviations for D1 and D2 lines are measured using a same experimental setup except for VCSEL wavelength and RF power. The Allan deviations, estimated from the frequency deviations, are-12/day for D1 line and-12/day for D2 line. In the case of D1 excitation, required RF frequency is 1.5 GHz and its power is only -8.0 dBm.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2009•0 citations

85Rb D1-Line Coherent-Population-Trapping Atomic Clock for Low-Power Operation

Shigeyoshi Goka

A 85Rb D1-line coherent-population-trapping (CPT) atomic clock with a natural-mixture Rb gas cell is demonstrated. D1-line excitation can generate a larger CPT resonance amplitude, and the choice of 85Rb rather than conventional 87Rb is because of its lower ground-state hyperfine-splitting frequency. The frequency deviation for the D1 line was measured using the same experimental setup as that for the D2 line except for the vertical-cavity surface-emitting laser (VCSEL) wavelength and RF power. In the case of D1-line excitation, the CPT resonance amplitude was 1.5 times that for the D2 line, and the light shift sensitivity was one-half that for the D2 line. The Allan standard deviations for the 85Rb D1 line, estimated from the frequency deviations, are <2.5×10-12 per day. In addition, the required RF is 1.5 GHz and its power is only -8.0 dBm.

Japanese Journal of Applied Physics•Jun 1, 2010•7 citations

Frequency Stability of Atomic Clocks Based on Coherent Population Trapping Resonance in 85 Rb

Lu Liu, Guo Tao, Ke Deng +3 more

An atomic clock system based on coherent population trapping (CPT) resonance in 85 Rb is reported, while most past works about the CPT clock are in 87 Rb. A new modulation method (full-hyperfine-frequency-splitting modulation) is presented to reduce the effect of light shift to improve the frequency stability of the CPT clock in 85 Rb. The experimental results show that the short-term frequency stability of the CPT clock in 85 Rb is in the order of 10 −10 /s and the long-term frequency stability can achieve 1.5 × 10 −11 /80000 s, which performs as well as 87 Rb in CPT resonance. This very good frequency stability performance associated with the low-cost and low-power properties of 85 Rb indicates that an atomic clock based on CPT in 85 Rb should be a promising candidate for making the chip scale atomic clock.

Chinese Physics Letters•Jun 28, 2007•9 citations

Low power 85Rb CPT atomic clock

Shigeyoshi Goka, Okura Taisuke, Moroyama Munetake +1 more

This paper outlines the features of the85Rb vapor cell atomic clock, the coherent population trapping (CPT) resonance in an85Rb/87Rb mixed vapor cell, and the results of the frequency stabilities of a pilot system. The experiments were performed with a sealed vapor cell containing a natural mixture of Rb isotopes and a buffer gas. Excitation of the CPT resonance was accomplished using a vertical-cavity surface-emitting laser modulated at 1.5, 3.0, 3.4 and 6.8 GHz, which corresponded to the full- and half-ground-state hyperfine frequencies of85Rb and87Rb. The results show that the CPT resonances at both85Rb and87Rb can be observed separately. The frequency stabilities of the output signals for each CPT resonance were ≪ 10x10−12/day for85Rb and ≪ 6x10−12/day for87Rb. In addition, the RF modulation signal power for85Rb was 1.1 dB less than that of87Rb, which was 3.4GHz.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2008•2 citations

A design and implementation of miniature CPT atomic clock based on ~(85)Rb

Duan We

A Coherent Population Trapping(CPT) atomic clock servo control circuit is designed based on the CPT phenomenon of 85 Rb. Taking MSP430 chip as a platform, combining with the physical device made up of Vecsel laser, photoelectric detector, and small 85 Rb vapor cell, a miniature atomic clock with the high-performance, high stability, low power consumption and small size is implemented. The volume is 31 cm3 and the power consumption is 660 m W. The frequency stability of 10 MHz measured is 2×10-10/s, 4×10-11/1 000 s. Full-hyperfine-splitting frequency modulation is used to improve the frequency stability.

Tai Hezi Kexue Yudianzi Xinxi Xuebao•Jan 1, 2015•0 citations

All-optical atomic clock based on coherent population trapping in ^85Rb

Mikko Merimaa, Thomas Lindvall, Ilkka Juhani Tittonen +1 more

An all-optical microwave frequency standard based on coherent population trapping (CPT) in 85Rb is developed. The CPT resonances are detected by an ordinary edge-emitting diode laser in a simple optical setup. A buffer-gas mixture is carefully optimized to yield a narrow linewidth and a reduced temperature dependence of the resonance frequency. With the developed system we are able to measure ultranarrow optically induced hyperfine CPT resonances at <20 Hz, which is in good agreement with the linewidth calculated from experimental parameters. The frequency of an RF-signal generator has been stabilized to the CPT resonance between the two mF=0 magnetic sublevels. The relative frequency stability (square root of Allan variance) follows a slope of 3.5×10-11 τ-1/2(1 s<τ<2000 s). The best stability of 6.4×10-13 is reached at an integration time of τ=2000 s. This stability is sufficient for many high-precision applications. Frequency-shift measurements were made to evaluate the frequency dependencies on the operation parameters.

Journal of the Optical Society of America B•Feb 1, 2003•131 citations
In this paper, the investigation of a 85 Rb coherent-population-trapping (CPT) atomic clock for low-power operation is described. The modulation profiles and CPT resonances for both 85 Rb and 87 Rb, the long-term frequency stabilities of the CPT resonance for both, and the feasibility of switching between low-power and high-stability operation modes are presented. The choice of 85 Rb rather than conventional 87 Rb is dictated by the lower ground-state hyperfine-splitting frequency, which leads to less than one-half the required RF power and more effective RF-related circuit designs. CPT resonances for both 85 Rb and 87 Rb can be observed separately in the same natural mixture Rb gas cell, and the linewidth is less than 120 Hz in both cases. The long-term frequency stabilities are <4.0 ×10 -12 /day for 85 Rb and <3.5 ×10 -12 /day for 87 Rb. These results indicate that a 85 Rb CPT atomic clock has a long-term stability of ∼4.0 ×10 -12 /day and consumes about one-half the RF power of a 87 Rb equivqlent. In addition, it is possible to switch between low-power and high-stability operation modes by changing the RF frequency and power.
This paper describes the investigation of a85Rb D1-line coherent population trapping (CPT) atomic clock with a Rb gas-cell containing a natural mixture of Rb atoms and buffer gas. The choice of85Rb rather than conventional87Rb is dictated by the lower ground-state hyperfine-splitting frequency, which leads to less than one-half the required RF power and more effective RF-related circuit designs. In this paper, the modulation profiles, the CPT resonances, and the long-term frequency stabilities of the CPT resonance for85Rb D1 and D2 lines are presented. The frequency deviations for D1 and D2 lines are measured using a same experimental setup except for VCSEL wavelength and RF power. The Allan deviations, estimated from the frequency deviations, are-12/day for D1 line and-12/day for D2 line. In the case of D1 excitation, required RF frequency is 1.5 GHz and its power is only -8.0 dBm.
A 85Rb D1-line coherent-population-trapping (CPT) atomic clock with a natural-mixture Rb gas cell is demonstrated. D1-line excitation can generate a larger CPT resonance amplitude, and the choice of 85Rb rather than conventional 87Rb is because of its lower ground-state hyperfine-splitting frequency. The frequency deviation for the D1 line was measured using the same experimental setup as that for the D2 line except for the vertical-cavity surface-emitting laser (VCSEL) wavelength and RF power. In the case of D1-line excitation, the CPT resonance amplitude was 1.5 times that for the D2 line, and the light shift sensitivity was one-half that for the D2 line. The Allan standard deviations for the 85Rb D1 line, estimated from the frequency deviations, are <2.5×10-12 per day. In addition, the required RF is 1.5 GHz and its power is only -8.0 dBm.
An atomic clock system based on coherent population trapping (CPT) resonance in 85 Rb is reported, while most past works about the CPT clock are in 87 Rb. A new modulation method (full-hyperfine-frequency-splitting modulation) is presented to reduce the effect of light shift to improve the frequency stability of the CPT clock in 85 Rb. The experimental results show that the short-term frequency stability of the CPT clock in 85 Rb is in the order of 10 −10 /s and the long-term frequency stability can achieve 1.5 × 10 −11 /80000 s, which performs as well as 87 Rb in CPT resonance. This very good frequency stability performance associated with the low-cost and low-power properties of 85 Rb indicates that an atomic clock based on CPT in 85 Rb should be a promising candidate for making the chip scale atomic clock.
This paper outlines the features of the85Rb vapor cell atomic clock, the coherent population trapping (CPT) resonance in an85Rb/87Rb mixed vapor cell, and the results of the frequency stabilities of a pilot system. The experiments were performed with a sealed vapor cell containing a natural mixture of Rb isotopes and a buffer gas. Excitation of the CPT resonance was accomplished using a vertical-cavity surface-emitting laser modulated at 1.5, 3.0, 3.4 and 6.8 GHz, which corresponded to the full- and half-ground-state hyperfine frequencies of85Rb and87Rb. The results show that the CPT resonances at both85Rb and87Rb can be observed separately. The frequency stabilities of the output signals for each CPT resonance were ≪ 10x10−12/day for85Rb and ≪ 6x10−12/day for87Rb. In addition, the RF modulation signal power for85Rb was 1.1 dB less than that of87Rb, which was 3.4GHz.
A Coherent Population Trapping(CPT) atomic clock servo control circuit is designed based on the CPT phenomenon of 85 Rb. Taking MSP430 chip as a platform, combining with the physical device made up of Vecsel laser, photoelectric detector, and small 85 Rb vapor cell, a miniature atomic clock with the high-performance, high stability, low power consumption and small size is implemented. The volume is 31 cm3 and the power consumption is 660 m W. The frequency stability of 10 MHz measured is 2×10-10/s, 4×10-11/1 000 s. Full-hyperfine-splitting frequency modulation is used to improve the frequency stability.
An all-optical microwave frequency standard based on coherent population trapping (CPT) in 85Rb is developed. The CPT resonances are detected by an ordinary edge-emitting diode laser in a simple optical setup. A buffer-gas mixture is carefully optimized to yield a narrow linewidth and a reduced temperature dependence of the resonance frequency. With the developed system we are able to measure ultranarrow optically induced hyperfine CPT resonances at <20 Hz, which is in good agreement with the linewidth calculated from experimental parameters. The frequency of an RF-signal generator has been stabilized to the CPT resonance between the two mF=0 magnetic sublevels. The relative frequency stability (square root of Allan variance) follows a slope of 3.5×10-11 τ-1/2(1 s<τ<2000 s). The best stability of 6.4×10-13 is reached at an integration time of τ=2000 s. This stability is sufficient for many high-precision applications. Frequency-shift measurements were made to evaluate the frequency dependencies on the operation parameters.