Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

International Symposium on Mesoscopic Superconductivity and Spintronics (MS+S)

DYNAMICS OF SUPERCONDUCTING FLUX-QUBIT MEASUREMENTS BY DC-SQUID

Hayato Nakano, Hideaki Takayanagi

Published Mar 1, 2003• 1 citation
Publisher

Abstract

In experiments of superconducting flux-qubit, a dc-SQUID has been used to read-out the qubit state. The value really obtained by the measurement is the switching current (I SW ) of the SQUID. In order to clarify the relation between the I SW and the qubit state, we calculated the time evolution of a composite system consisting of a dc-SQUID and flux-qubit. The entanglement formation and the transition to mixed-states, which are caused by the interaction between the SQUID and the qubit, are discussed.

DOI
10.1142/9789812705556_0060

Related papers

A theoretical analysis of flux-qubit measurements with a dc-SQUID

Nakano, H., Hirotaka Tanaka, Shiro Saito +3 more

The readout process of a superconducting flux-qubit is theoretically analyzed in terms of the quantum dynamics of a qubit-SQUID coupled system during measurement. The quantity directly observed by the measurement is the switching current (Isw) of the dc-SQUID placed around the qubit ring. In order to clarify the relation between the Isw and the qubit state, we calculated the time evolution of the density operator of the qubit-SQUID system while increasing the SQUID bias current until switching events occur and obtained the switching current distributions. This clarifies what information of the qubit is obtained by a dc-SQUID switching current measurement under specific conditions, for example, when the qubit eigenstate is a superposition of two different flux states.

arXiv:cond-mat/0406622•Jun 25, 2004•12 citations

MULTIPHOTON ABSORPTION AND SQUID SWITCHING CURRENT BEHAVIORS IN SUPERCONDUCTING FLUX-QUBIT EXPERIMENTS

Hideaki Takayanagi, Hayato Nakano, Hirotaka Tanaka +3 more

We observed multiphoton absorptions accompanied by the transition between our superconducting flux-qubit states, those are the superposition of two macroscopically distinct states. We also report a systematic view on the switching current behavior of the readout dc-SQUID, depending on the sample parameters of the qubit and the SQUID.

International Symposium on Mesoscopic Superconductivity and Spintronics (MS+S)•Aug 1, 2005•0 citations

Dc SQUID sensitivity for readout of entangled state quantum bits

H Tanaka, Y Sekine, S Saito +1 more

We propose a scheme for entangled state measurement at flux qubits (quantum bits) depending on the sensitivity measurement of a dc SQUID (superconducting quantum interference device). The dc SQUID is used as a flux qubit readout device. The switching current distribution of the dc SQUID is sufficiently narrow to distinguish between two ground states of three Josephson junction qubits with a large mutual inductance between a qubit and the dc SQUID. However, discrimination between two ground states becomes difficult with the smaller mutual inductance that is preferable for qubit coherence. We employed averaging to increase the effective sensitivity. However the averaging smears out the entanglement over two qubits. We found that a Bell-pair measurement can be performed with flux qubits to prove the existence of an entangled state over two qubits. The pre-ensembled measurement scheme, in which our flux qubit readouts work, is preferable to entangled state measurement.

arXiv:cond-mat/0108231•Superconductor Science and Technology•Nov 21, 2001•12 citations

Quantum state detection of a superconducting flux qubit using a dc-SQUID in the inductive mode

Adrian Lupaşcu, C. J. P. M. Harmans, Johan E. Mooij

We present a readout method for superconducting flux qubits. The qubit quantum flux state can be measured by determining the Josephson inductance of an inductively coupled dc superconducting quantum interference device (dc-SQUID). We determine the response function of the dc-SQUID and its back-action on the qubit during measurement. Due to driving, the qubit energy relaxation rate depends on the spectral density of the measurement circuit noise at sum and difference frequencies of the qubit Larmor frequency and SQUID driving frequency. The qubit dephasing rate is proportional to the spectral density of circuit noise at the SQUID driving frequency. These features of the back-action are qualitatively different from the case when the SQUID is used in the usual switching mode. For a particular type of readout circuit with feasible parameters we find that single shot readout of a superconducting flux qubit is possible.

arXiv:cond-mat/0410730•Physical Review B•May 13, 2005•30 citations

A hysteretic dc SQUID reading the flux states of an rf SQUID

C. Cosmelli, P. Carelli, Maria Gabriella Castellano +3 more

We have realized a hysteretic dc SQUID to measure the flux states of a rf SQUID inductively coupled to the hysteretic dc SQUID. This type of measurement is required whenever is necessary to make a non invasive measure of the state of the rf SQUID. This is the case of measurements of macroscopic quantum coherence or measurements on q-bits systems. With the proposed set up the hysteretic dc SQUID can switch from the superconducting to the normal state depending on the total applied magnetic flux. On this system we measured at 4.2 K the change on the switching probability of the dc SQUID by varying the flux state of the rf SQUID. The experimental results agree very well with the theoretical predictions showing that this device can be used to perform non invasive measurements of the rf SQUID flux state.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•15 citations

Observation of Qubit State with a dc-SQUID and Dissipation Effect in the SQUID

Hideaki Takayanagi, Hirotaka Tanaka, Shiro Saito +1 more

Two states of a flux qubit with three Josephson junctions were shown in a single measurement with a dc-SQUID. The qubit is an aluminum superconductor loop surrounded by a dc-SQUID for readout. It has two states, which have persistent currents flowing in opposite directions. The readout data for three samples with different junction sizes suggest that the probability distribution for the double-well potential depends on the ratio of E J /E C , where E J is the Josephson energy and E C is the charging energy. The probability distribution was estimated by calculating the wavefunctions and energy levels for the measured samples. We measured the retrapping current of a dc-SQUID without the qubit as a function of the magnetic field. It was found that the relative phase relation for the magnetic field dependence of the retrapping current jumped from 0 to π at E J ≈ E C . This jump can be explained phenomenologically by taking into account the two kinds of dissipation arising from ac currents flowing through the lead and along the SQUID loop. The fact that the jump occurred at E J ≈ E C strongly suggests that the quantum nature of the electromagnetic environment needs to be taken into account in order to understand the origin of the dissipation.

Condensation and Coherence in Condensed Matter•Mar 1, 2003•0 citations
In experiments of superconducting flux-qubit, a dc-SQUID has been used to read-out the qubit state. The value really obtained by the measurement is the switching current (I SW ) of the SQUID. In order to clarify the relation between the I SW and the qubit state, we calculated the time evolution of a composite system consisting of a dc-SQUID and flux-qubit. The entanglement formation and the transition to mixed-states, which are caused by the interaction between the SQUID and the qubit, are discussed.
The readout process of a superconducting flux-qubit is theoretically analyzed in terms of the quantum dynamics of a qubit-SQUID coupled system during measurement. The quantity directly observed by the measurement is the switching current (Isw) of the dc-SQUID placed around the qubit ring. In order to clarify the relation between the Isw and the qubit state, we calculated the time evolution of the density operator of the qubit-SQUID system while increasing the SQUID bias current until switching events occur and obtained the switching current distributions. This clarifies what information of the qubit is obtained by a dc-SQUID switching current measurement under specific conditions, for example, when the qubit eigenstate is a superposition of two different flux states.
We propose a scheme for entangled state measurement at flux qubits (quantum bits) depending on the sensitivity measurement of a dc SQUID (superconducting quantum interference device). The dc SQUID is used as a flux qubit readout device. The switching current distribution of the dc SQUID is sufficiently narrow to distinguish between two ground states of three Josephson junction qubits with a large mutual inductance between a qubit and the dc SQUID. However, discrimination between two ground states becomes difficult with the smaller mutual inductance that is preferable for qubit coherence. We employed averaging to increase the effective sensitivity. However the averaging smears out the entanglement over two qubits. We found that a Bell-pair measurement can be performed with flux qubits to prove the existence of an entangled state over two qubits. The pre-ensembled measurement scheme, in which our flux qubit readouts work, is preferable to entangled state measurement.
We present a readout method for superconducting flux qubits. The qubit quantum flux state can be measured by determining the Josephson inductance of an inductively coupled dc superconducting quantum interference device (dc-SQUID). We determine the response function of the dc-SQUID and its back-action on the qubit during measurement. Due to driving, the qubit energy relaxation rate depends on the spectral density of the measurement circuit noise at sum and difference frequencies of the qubit Larmor frequency and SQUID driving frequency. The qubit dephasing rate is proportional to the spectral density of circuit noise at the SQUID driving frequency. These features of the back-action are qualitatively different from the case when the SQUID is used in the usual switching mode. For a particular type of readout circuit with feasible parameters we find that single shot readout of a superconducting flux qubit is possible.
We have realized a hysteretic dc SQUID to measure the flux states of a rf SQUID inductively coupled to the hysteretic dc SQUID. This type of measurement is required whenever is necessary to make a non invasive measure of the state of the rf SQUID. This is the case of measurements of macroscopic quantum coherence or measurements on q-bits systems. With the proposed set up the hysteretic dc SQUID can switch from the superconducting to the normal state depending on the total applied magnetic flux. On this system we measured at 4.2 K the change on the switching probability of the dc SQUID by varying the flux state of the rf SQUID. The experimental results agree very well with the theoretical predictions showing that this device can be used to perform non invasive measurements of the rf SQUID flux state.
Two states of a flux qubit with three Josephson junctions were shown in a single measurement with a dc-SQUID. The qubit is an aluminum superconductor loop surrounded by a dc-SQUID for readout. It has two states, which have persistent currents flowing in opposite directions. The readout data for three samples with different junction sizes suggest that the probability distribution for the double-well potential depends on the ratio of E J /E C , where E J is the Josephson energy and E C is the charging energy. The probability distribution was estimated by calculating the wavefunctions and energy levels for the measured samples. We measured the retrapping current of a dc-SQUID without the qubit as a function of the magnetic field. It was found that the relative phase relation for the magnetic field dependence of the retrapping current jumped from 0 to π at E J ≈ E C . This jump can be explained phenomenologically by taking into account the two kinds of dissipation arising from ac currents flowing through the lead and along the SQUID loop. The fact that the jump occurred at E J ≈ E C strongly suggests that the quantum nature of the electromagnetic environment needs to be taken into account in order to understand the origin of the dissipation.