Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physica B Condensed Matter

High-sensitivity DC-SQUID measurements

Pasquale Carelli, Maria Gabriella Castellano

Published May 1, 2000• 6 citations
Publisher
DOI
10.1016/s0921-4526(99)01855-4

Related papers

Current noise measured in the dc SQUID

John M. Martinis, John L. Clarke

Journal of Low Temperature Physics•Dec 1, 1986•13 citations

A dc SQUID coupled to a high Q electrical resonator

P. Falferi, R. Mezzena, MASSIMO CERDONIO +3 more

Czechoslovak Journal of Physics•May 1, 1996•1 citation

Maximum attainable sensitivity of dc squids built with Josephson tunnel junctions

Oleg V. Snigirev

RpEEE•Apr 1, 1985•0 citations

A High-Frequency DC SQUID Magnetic Sensor Design

Shihao Wang, Odette S. Bakam Nguenouho, Jean‐François Bousquet

This paper presents a SQUID-based quantum sensor for ultra-sensitive magnetic field detection, comprising a two-stage architecture utilizing the DC SQUID as a front-end sensor as well as for the Josephson Parametric Amplifier (JPA) in the second stage. The work details the circuit design and characteristics of the DC SQUID, introduces the challenges associated with high-frequency sensing, and analyzes the nonlinear behavior in the superconducting region crucial for ultra-sensitive detection. Furthermore, it demonstrates the gain enhancements achieved through the parametric amplifier and establishes a good match between device measurement results and the behavioral model.

IEEE International Conference on Quantum Computing and Engineering (QCE)•Sep 15, 2024•2 citations

DC SQUID AND ITS LOW-FREQUENCY APPLICATIONS

Heikki Seppä, Tapani Ryhänen, Risto Juhani Ilmoniemi +1 more

WORLD SCIENTIFIC eBooks•Jul 1, 1991•0 citations

Amplification by Frequency Transposition with a Low Critical Temperature DC SQUID

Olivier Hubert, Yves Monfort, Jacques Lepaisant +2 more

The performances of a heterodyne amplifier involving a DC SQUID have been modelised and measured. This type of amplification is derived from frequency translation methods using flux modulation. The pump frequency used depends on the signal to be analysed and the translation to a fixed frequency f0 is carried out by the SQUID which is a nonlinear device. Such a system simplifies the impedance matching between the SQUID and the semiconductor preamplifier and can be operated as a spectrum analyser for signals of relatively high and variable frequency. Flux sensitivities of 5 to 10 $\mu\Phi_{0}/\sqrt{\rm Hz}$ have been measured in this configuration for frequencies ranging from 200 kHz to 2 MHz. In order to validate our model, the flux sensitivity of the SQUID in the heterodyne configuration has been compared to that given by direct measurements at the intermediate frequency f0. Our measurements are in good agreement with a theoretical model based on a simplified voltage to flux characteristic of the DC SQUID.

Journal de Physique III•Jan 1, 1996•0 citations
This paper presents a SQUID-based quantum sensor for ultra-sensitive magnetic field detection, comprising a two-stage architecture utilizing the DC SQUID as a front-end sensor as well as for the Josephson Parametric Amplifier (JPA) in the second stage. The work details the circuit design and characteristics of the DC SQUID, introduces the challenges associated with high-frequency sensing, and analyzes the nonlinear behavior in the superconducting region crucial for ultra-sensitive detection. Furthermore, it demonstrates the gain enhancements achieved through the parametric amplifier and establishes a good match between device measurement results and the behavioral model.
The performances of a heterodyne amplifier involving a DC SQUID have been modelised and measured. This type of amplification is derived from frequency translation methods using flux modulation. The pump frequency used depends on the signal to be analysed and the translation to a fixed frequency f0 is carried out by the SQUID which is a nonlinear device. Such a system simplifies the impedance matching between the SQUID and the semiconductor preamplifier and can be operated as a spectrum analyser for signals of relatively high and variable frequency. Flux sensitivities of 5 to 10 μΦ0/Hz\mu\Phi_{0}/\sqrt{\rm Hz}μΦ0​/Hz​ have been measured in this configuration for frequencies ranging from 200 kHz to 2 MHz. In order to validate our model, the flux sensitivity of the SQUID in the heterodyne configuration has been compared to that given by direct measurements at the intermediate frequency f0. Our measurements are in good agreement with a theoretical model based on a simplified voltage to flux characteristic of the DC SQUID.