Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Low Temperature Physics

Current noise measured in the dc SQUID

John M. Martinis, John L. Clarke

Published Dec 1, 1986• 13 citations
Publisher
DOI
10.1007/bf00684012

Related papers

Noise Measurements on DC-SQUIDs with Varied Design

M. R. Condron, G.M. Gutt, B. Muhlfelder +5 more

Springer proceedings in physics•Jan 1, 1992•4 citations

Noise in a point-contact dc SQUID

Kenneth R. Carroll, Ho Jung Paik

Journal of Low Temperature Physics•May 1, 1989•1 citation

Measurements of current noise in DC SQUIDS

John M. Martinis, John L. Clarke

The current noise circulating around the loop of a tunnel junction dc SQUID has been measured as a function of applied flux. The flux noise generated by this current was coupled via a superconducting transformer to a second dc SQUID that was used to measure the noise in a null-balancing configuration. The voltage noise across the SQUID was also measured, using a cooled LC-resonant circuit, and the correlation between the voltage and current noises was determined. The measured values of the noises are in good agreement with values obtained from an analog simulator.

IEEE Transactions on Magnetics•May 1, 1983•21 citations

Noise Measurements in dc-SQUIDs Based on Nb — NbOx — PbAuIn Josephson Junctions

M. Pullano, P. Carelli, Vittorio Foglietti +2 more

NATO ASI series. Series B : Physics•Jan 1, 1990•0 citations

Investigation of 1/f noise in tunnel junction DC SQUIDS

R. H. Koch, John L. Clarke, John M. Martinis +3 more

We describe two methods of measuring the 1/f noise in a dc SQUID. One is sensitive only to 1/f noise in the critical currents of the junctions, and the other is sensitive only to 1/f flux noise that is not associated with critical current fluctuations. From measurements on a planar thin-film dc SQUID incorporating Josephson tunnel junctions we conclude that the predominant source of 1/f noise is not noise in the crititcal currents, but rather an apparent flux noise of unknown origin.

IEEE Transactions on Magnetics•May 1, 1983•11 citations

High-sensitivity DC-SQUID measurements

Pasquale Carelli, Maria Gabriella Castellano

Physica B Condensed Matter•May 1, 2000•6 citations
The current noise circulating around the loop of a tunnel junction dc SQUID has been measured as a function of applied flux. The flux noise generated by this current was coupled via a superconducting transformer to a second dc SQUID that was used to measure the noise in a null-balancing configuration. The voltage noise across the SQUID was also measured, using a cooled LC-resonant circuit, and the correlation between the voltage and current noises was determined. The measured values of the noises are in good agreement with values obtained from an analog simulator.