Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Single-electron transistor as a radio-frequency mixer

Robert G. Knobel, Christopher S. Yung, Andrew N. Cleland

Published Jul 15, 2002• 57 citations
Publisher

Abstract

We demonstrate the use of the single-electron transistor as a radio-frequency mixer, based on the nonlinear dependence of current on gate charge. This mixer can be used for high-frequency, ultrasensitive charge measurements over a broad and tunable range of frequencies. We demonstrate operation of the mixer, using a lithographically defined thin-film aluminum transistor, in both the superconducting and normal states of aluminum, over frequencies from 10 to 300 MHz. We have operated the device both as a homodyne detector and as a phase-sensitive heterodyne mixer. We demonstrate a charge sensitivity of <4×10−3 e/Hz, limited by room-temperature electronics. An optimized mixer has a theoretical charge sensitivity of ≲1.5×10−5 e/Hz.

DOI
10.1063/1.1493221

Related papers

An ultrasensitive radio-frequency single-electron transistor working up to 4.2 K

Henrik Brenning, Sergey G. Kafanov, T. Duty +2 more

We present the measurement of a radio-frequency single-electron transistor that displays a very high charge sensitivity of 1.9 μe Hz at 4.2 K. At 40 mK, the charge sensitivity is 0.9 and 1.0 μe Hz in the superconducting and normal state, respectively. The sensitivity was measured as a function of radio frequency amplitude at three different temperatures; 40 mK, 1.8, and 4.2 K.

•Jan 1, 2006•51 citations

An ultrasensitive radio-frequency single-electron transistor working up to 4.2 K

Henrik Brenning, Sergey G. Kafanov, T. Duty +2 more

We present the measurement of a radio-frequency single-electron transistor that displays a very high charge sensitivity of 1.9 μe∕Hz at 4.2 K. At 40 mK, the charge sensitivity is 0.9 and 1.0 μe∕Hz in the superconducting and normal state, respectively. The sensitivity was measured as a function of radio frequency amplitude at three different temperatures; 40 mK, 1.8, and 4.2 K.

arXiv:cond-mat/0602518•Journal of Applied Physics•Dec 1, 2006•73 citations

Mixing with the radio frequency single-electron transistor

Loren J. Swenson, Daniel R. Schmidt, J. S. Aldridge +2 more

By configuring a radio frequency single-electron transistor as a mixer, we demonstrate a unique implementation of this device, that achieves good charge sensitivity with large bandwidth about a tunable center frequency. In our implementation we achieve a measurement bandwidth of 16 MHz, with a tunable center frequency from 0 to 1.2 GHz, demonstrated with the transistor operating at 300 mK. Ultimately this device is limited in center frequency by the RC time of the transistor’s center island, which for our device is ∼1.6GHz, close to the measured value. The measurement bandwidth is determined by the quality factor of the readout tank circuit.

arXiv:cond-mat/0501623•Applied Physics Letters•Apr 20, 2005•7 citations

Radio-frequency single-electron transistor: Toward the shot-noise limit

A. Aassime, David Gunnarsson, Kevin Bladh +2 more

We have fabricated an aluminum single-electron transistor and characterized it at frequencies up to 10 MHz by measuring the reflected signal from a resonant tank in which the transistor is embedded. We measured the charge sensitivity of this radio-frequency single-electron transistor to be 3.2×10−6 e/Hz, which corresponds to the uncoupled energy sensitivity of 4.8 ℏ. Our measurements indicate that with further improvements, the radio-frequency single-electron transistor could reach the shot-noise limit estimated to be about 1 ℏ.

Applied Physics Letters•Dec 10, 2001•88 citations

The Radio-Frequency Single-Electron Transistor (RF-SET): A Fast and Ultrasensitive Electrometer

R. J. Schoelkopf, Paula Wahlgren, A. A. Kozhevnikov +2 more

A new type of electrometer is described that uses a single-electron transistor (SET) and that allows large operating speeds and extremely high charge sensitivity. The SET readout was accomplished by measuring the damping of a 1.7-gigahertz resonant circuit in which the device is embedded, and in some ways is the electrostatic "dual" of the well-known radio-frequency superconducting quantum interference device. The device is more than two orders of magnitude faster than previous single-electron devices, with a constant gain from dc to greater than 100 megahertz. For a still-unoptimized device, a charge sensitivity of 1.2 x 10(-5) e/hertz was obtained at a frequency of 1.1 megahertz, which is about an order of magnitude better than a typical, 1/f-noise-limited SET, and corresponds to an energy sensitivity (in joules per hertz) of about 41 Planck's over 2pi.

Science•May 22, 1998•776 citations

Inductive Single-Electron Transistor

Mika A. Sillanpää, Leif Roschier, Pertti Juhani Hakonen

We demonstrate a sensitive method of charge detection based on radio-frequency readout of the Josephson inductance of a superconducting single-electron transistor. Charge sensitivity 1.4 x 10(-4) e/square root Hz, limited by a preamplifier, is achieved in an operation mode which takes advantage of the nonlinearity of the Josephson potential. Owing to reactive readout, our setup has more than 2 orders of magnitude lower dissipation than the existing method of radio-frequency electrometry. With an optimized sample, we expect uncoupled energy sensitivity below variant Planck's over h in the same experimental scheme.

arXiv:cond-mat/0402045•Physical Review Letters•Aug 6, 2004•45 citations
We demonstrate the use of the single-electron transistor as a radio-frequency mixer, based on the nonlinear dependence of current on gate charge. This mixer can be used for high-frequency, ultrasensitive charge measurements over a broad and tunable range of frequencies. We demonstrate operation of the mixer, using a lithographically defined thin-film aluminum transistor, in both the superconducting and normal states of aluminum, over frequencies from 10 to 300 MHz. We have operated the device both as a homodyne detector and as a phase-sensitive heterodyne mixer. We demonstrate a charge sensitivity of <4×10−3 e/Hz, limited by room-temperature electronics. An optimized mixer has a theoretical charge sensitivity of ≲1.5×10−5 e/Hz.
By configuring a radio frequency single-electron transistor as a mixer, we demonstrate a unique implementation of this device, that achieves good charge sensitivity with large bandwidth about a tunable center frequency. In our implementation we achieve a measurement bandwidth of 16 MHz, with a tunable center frequency from 0 to 1.2 GHz, demonstrated with the transistor operating at 300 mK. Ultimately this device is limited in center frequency by the RC time of the transistor’s center island, which for our device is ∼1.6GHz, close to the measured value. The measurement bandwidth is determined by the quality factor of the readout tank circuit.
We have fabricated an aluminum single-electron transistor and characterized it at frequencies up to 10 MHz by measuring the reflected signal from a resonant tank in which the transistor is embedded. We measured the charge sensitivity of this radio-frequency single-electron transistor to be 3.2×10−6 e/Hz, which corresponds to the uncoupled energy sensitivity of 4.8 ℏ. Our measurements indicate that with further improvements, the radio-frequency single-electron transistor could reach the shot-noise limit estimated to be about 1 ℏ.
A new type of electrometer is described that uses a single-electron transistor (SET) and that allows large operating speeds and extremely high charge sensitivity. The SET readout was accomplished by measuring the damping of a 1.7-gigahertz resonant circuit in which the device is embedded, and in some ways is the electrostatic "dual" of the well-known radio-frequency superconducting quantum interference device. The device is more than two orders of magnitude faster than previous single-electron devices, with a constant gain from dc to greater than 100 megahertz. For a still-unoptimized device, a charge sensitivity of 1.2 x 10(-5) e/hertz was obtained at a frequency of 1.1 megahertz, which is about an order of magnitude better than a typical, 1/f-noise-limited SET, and corresponds to an energy sensitivity (in joules per hertz) of about 41 Planck's over 2pi.
We demonstrate a sensitive method of charge detection based on radio-frequency readout of the Josephson inductance of a superconducting single-electron transistor. Charge sensitivity 1.4 x 10(-4) e/square root Hz, limited by a preamplifier, is achieved in an operation mode which takes advantage of the nonlinearity of the Josephson potential. Owing to reactive readout, our setup has more than 2 orders of magnitude lower dissipation than the existing method of radio-frequency electrometry. With an optimized sample, we expect uncoupled energy sensitivity below variant Planck's over h in the same experimental scheme.