Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)

Fast and non-destructive vector field magnetometry with cold atomic ensembles

N. Behbood, Ferran Martin Ciurana, Giorgio Colangelo, M. Napolitano, R. J. Sewell, Morgan W. Mitchell

Published May 1, 2013• 0 citations
Publisher

Abstract

This paper reports on a fast, nondestructive and sensitive measurement technique that uses atomic spin precession and non-destructive Faraday rotation probing to measure all three components of the magnetic field with kHz bandwidth. In contrast to other vector magnetometer techniques that modulate an applied magnetic field, here the initial atomic polarization is modulated and the magnetic field components are extracted from the resulting free-induction decay (FID) signal, monitored via paramagnetic Faraday rotation. An ensemble of up to 106cold87Rb in the F = 1 hyperfine ground state was used and held in an optical trap as the field sensor.

DOI
10.1109/cleoe-iqec.2013.6801671

Related papers

Real-time vector field tracking with a cold-atom magnetometer

N. Behbood, Ferran Martin Ciurana, Giorgio Colangelo +3 more

We demonstrate a fast three-axis optical magnetometer using cold, optically trapped 87Rb gas as a sensor. By near-resonant Faraday rotation we record the free-induction decay of a spin polarized ensemble following optical to obtain the three field components and one gradient component. A single measurement achieves shot-noise limited sub-nT sensitivity in 1 ms, with transverse spatial resolution of ∼20 μm. We make a detailed analysis of the shot-noise-limited sensitivity.

arXiv:1303.2312•Applied Physics Letters•Apr 29, 2013•64 citations

High bandwidth three-axis magnetometer based on optically polarized 85 Rb under unshielded environment

Hongying Yang, Ke Zhang, Yanhua Wang +1 more

Abstract In this paper, we demonstrate a three-axis atomic magnetometer based on parametric oscillations, which can measure the three magnetic field components simultaneously and independently. A circularly polarized pump beam is applied to create the spin polarization, and another linearly polarized probe beam is used to detect the dynamics of the polarized spin under a magnetic field. With a closed-loop system to keep the magnetic field in resonance with the atoms, three components of magnetic field are measured by their feedback signals. We achieve a magnetometer sensitivity of 6 pT ( ) −1 , 25 pT ( ) −1 , and 60 pT ( ) −1 along three axes in the frequency range from 100 Hz to 1 kHz with a bandwidth better than 1 kHz under an unshielded environment. Furthermore, this magnetometer is free of optical modulation, which reduces the complexity of experimental setups. The methods we present here provide a prototype all-electrical three-axis atomic magnetometer.

Journal of Physics D Applied Physics•Nov 4, 2019•23 citations

Dead-zone-free orientation-based pulsed atomic magnetometer

Jinghong Xu, Liwei Jiang, Yuntian Zou +6 more

The dead zones of atomic magnetometers bring great challenges for the mobile applications in high-sensitivity magnetic field measurement. To solve this fundamental problem, we present a dead-zone-free orientation-based atomic magnetometer employing free-induction-decay (FID) scheme. A modulation scheme combining synchronous optical pumping and radio frequency pulse manipulation is utilized to achieve the free precession of spin polarization in all magnetic field orientations, and the FID signals are detected in two directions with an orthogonal pump-probe light configuration. We perform a comprehensive theoretical analysis of spin polarization evolution for arbitrary magnetic field orientations, and both simulation and experimental results demonstrate that the fusion of information from the pump and probe beams enables the dead-zone-free measurement of the magnetometer, with the sensor exhibiting a sensitivity in the range of 0.6 – 1.4 pT / Hz 1 / 2 across all directions. The proposed scheme is of great significance for the advancement of pulsed atomic magnetometers and their various applications in mobile platforms.

Physical Review Research•Apr 6, 2026•0 citations

Three-axis atomic magnetometer based on spin precession modulation

Hao Huang, Hai Feng Dong, Xiaofei Hu +2 more

We demonstrate a three-axis atomic magnetometer with one intensity-modulated pump beam and one orthogonal probe beam. The main field component is measured using the resonance of the pumping light, while the transverse field components are measured simultaneously using the optical rotation of the probe beam modulated by the spin precession. It is an all-optical magnetometer without using any modulation field or radio frequency field. Magnetic field sensitivity of 0.8 pT/Hz1∕2 is achieved under a bias field of 2 μT.

Applied Physics Letters•Nov 2, 2015•60 citations

Dead-zone-free single-beam atomic magnetometer based on free-induction-decay of Rb atoms

Shrey Mehta, G. K. Samanta, Raghwinder Singh Grewal

Free-induction-decay (FID) magnetometers have evolved as simple magnetic sensors for sensitive detection of unknown magnetic fields. However, these magnetometers suffer from a fundamental problem known as a “dead zone,” making them insensitive to certain magnetic field directions. Here, we demonstrate a simple experimental scheme for the dead-zone-free operation of a FID atomic magnetometer. Using a single laser beam containing equal strength of linear- and circular-polarization components and amplitude modulation at a low-duty cycle, we have synchronously pumped the rubidium (87Rb) atoms with both first- and second-order frequency harmonics. Such a pumping scheme has enabled us to observe the free Larmor precession of atomic spins at a frequency of ΩL (orientation) and/or 2ΩL (alignment) in a single FID signal, depending on the direction of the external magnetic field. We observed that the amplitude of the FID signal does not go to zero for any magnetic field direction, proving the absence of dead zones in the magnetometer. The magnetometer has a sensitivity in the range of 3.2–8.4 pT/Hz in all directions. Our experimental scheme can be crucial in developing miniaturized atomic magnetometers for various practical applications, including geomagnetic applications.

arXiv:2410.15663•Applied Physics Letters•Jan 27, 2025•8 citations

Vector measurements using all optical scalar atomic magnetometers

Rui Zhang, Rahul Mhaskar, Ken Smith +2 more

Vector field measurement is demonstrated with an all-optical scalar atomic magnetometer using intrinsic parameters related to its scalar operation. The Bell-Bloom type atomic magnetometer measures the Larmor precession of cesium atoms through on-resonant absorption of a probe beam. While the AC component of the probe signal is used for the field magnitude measurement, the probe DC signal contains information about the polar angle, defined as the angle between the magnetic field and the probe beam. Additional polar angle information is obtained from the light-shift-induced magnetic field caused by the frequency modulation of the probe beam. With a measurement time of 100 ms, better than 0.02° sensitivity has been achieved using a commercial miniaturized sensor at the optimal sensor orientation. The angle measurement accuracy is checked against an optical encoder over the entire polar angle range of 0°–180°. Better than 1° error is recorded over most set polar angles. Azimuthal angle measurement is also exhibited with two orthogonally oriented sensors.

arXiv:2011.08943•Journal of Applied Physics•Jan 28, 2021•17 citations
This paper reports on a fast, nondestructive and sensitive measurement technique that uses atomic spin precession and non-destructive Faraday rotation probing to measure all three components of the magnetic field with kHz bandwidth. In contrast to other vector magnetometer techniques that modulate an applied magnetic field, here the initial atomic polarization is modulated and the magnetic field components are extracted from the resulting free-induction decay (FID) signal, monitored via paramagnetic Faraday rotation. An ensemble of up to 106cold87Rb in the F = 1 hyperfine ground state was used and held in an optical trap as the field sensor.
Abstract In this paper, we demonstrate a three-axis atomic magnetometer based on parametric oscillations, which can measure the three magnetic field components simultaneously and independently. A circularly polarized pump beam is applied to create the spin polarization, and another linearly polarized probe beam is used to detect the dynamics of the polarized spin under a magnetic field. With a closed-loop system to keep the magnetic field in resonance with the atoms, three components of magnetic field are measured by their feedback signals. We achieve a magnetometer sensitivity of 6 pT ( ) −1 , 25 pT ( ) −1 , and 60 pT ( ) −1 along three axes in the frequency range from 100 Hz to 1 kHz with a bandwidth better than 1 kHz under an unshielded environment. Furthermore, this magnetometer is free of optical modulation, which reduces the complexity of experimental setups. The methods we present here provide a prototype all-electrical three-axis atomic magnetometer.
The dead zones of atomic magnetometers bring great challenges for the mobile applications in high-sensitivity magnetic field measurement. To solve this fundamental problem, we present a dead-zone-free orientation-based atomic magnetometer employing free-induction-decay (FID) scheme. A modulation scheme combining synchronous optical pumping and radio frequency pulse manipulation is utilized to achieve the free precession of spin polarization in all magnetic field orientations, and the FID signals are detected in two directions with an orthogonal pump-probe light configuration. We perform a comprehensive theoretical analysis of spin polarization evolution for arbitrary magnetic field orientations, and both simulation and experimental results demonstrate that the fusion of information from the pump and probe beams enables the dead-zone-free measurement of the magnetometer, with the sensor exhibiting a sensitivity in the range of 0.6 – 1.4 pT / Hz 1 / 2 across all directions. The proposed scheme is of great significance for the advancement of pulsed atomic magnetometers and their various applications in mobile platforms.
We demonstrate a three-axis atomic magnetometer with one intensity-modulated pump beam and one orthogonal probe beam. The main field component is measured using the resonance of the pumping light, while the transverse field components are measured simultaneously using the optical rotation of the probe beam modulated by the spin precession. It is an all-optical magnetometer without using any modulation field or radio frequency field. Magnetic field sensitivity of 0.8 pT/Hz1∕2 is achieved under a bias field of 2 μT.
Free-induction-decay (FID) magnetometers have evolved as simple magnetic sensors for sensitive detection of unknown magnetic fields. However, these magnetometers suffer from a fundamental problem known as a “dead zone,” making them insensitive to certain magnetic field directions. Here, we demonstrate a simple experimental scheme for the dead-zone-free operation of a FID atomic magnetometer. Using a single laser beam containing equal strength of linear- and circular-polarization components and amplitude modulation at a low-duty cycle, we have synchronously pumped the rubidium (87Rb) atoms with both first- and second-order frequency harmonics. Such a pumping scheme has enabled us to observe the free Larmor precession of atomic spins at a frequency of ΩL (orientation) and/or 2ΩL (alignment) in a single FID signal, depending on the direction of the external magnetic field. We observed that the amplitude of the FID signal does not go to zero for any magnetic field direction, proving the absence of dead zones in the magnetometer. The magnetometer has a sensitivity in the range of 3.2–8.4 pT/Hz in all directions. Our experimental scheme can be crucial in developing miniaturized atomic magnetometers for various practical applications, including geomagnetic applications.
Vector field measurement is demonstrated with an all-optical scalar atomic magnetometer using intrinsic parameters related to its scalar operation. The Bell-Bloom type atomic magnetometer measures the Larmor precession of cesium atoms through on-resonant absorption of a probe beam. While the AC component of the probe signal is used for the field magnitude measurement, the probe DC signal contains information about the polar angle, defined as the angle between the magnetic field and the probe beam. Additional polar angle information is obtained from the light-shift-induced magnetic field caused by the frequency modulation of the probe beam. With a measurement time of 100 ms, better than 0.02° sensitivity has been achieved using a commercial miniaturized sensor at the optimal sensor orientation. The angle measurement accuracy is checked against an optical encoder over the entire polar angle range of 0°–180°. Better than 1° error is recorded over most set polar angles. Azimuthal angle measurement is also exhibited with two orthogonally oriented sensors.