Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Designing a special light source with predetermined number of photons

Dániel Oszetzky, A. Czitrovszky, Alexander V. Sergienko

Published Feb 3, 2004• 5 citations
Publisher

Abstract

We designed a special light source generating a pre-determined number of photons taking advantage of our previous experimental results and calculations that establish a new approach to the calibration of photodetectors and determination of the absolute value of quantum efficiency of photon-counting photomultipliers using a single detector and entangled-photon pairs. This source is capable of generating a known number of photons of specified wavelength, in specified direction, and polarization for high-accuracy optical measurements (optical metrology) at the ultra-low intensities. The design and the modeling have been performed taking into account the main time characteristics of electronics, efficiency of detectors, parameters of the signal, losses, etc. The data evaluation system has been designed and tested; the assembly of the experimental set-up has been performed. Main parts of the optical and electronic system (generation of photon pairs, detectors, Pockels cells, etc.) have been tested. Such light source can be successfully applied in different areas of optical metrology, especially in photometry.

DOI
10.1117/12.506697

Related papers

Controllable photon source

Dániel Oszetzky, Attila Nagy, A. Czitrovszky

We have developed our pervious experimental setup using correlated photon pairs (to the calibration of photo detectors) to realize a controllable photon source. For the generation of such photon pairs we use the non-linear process of parametric down conversion. When a photon of the pump beam is incident to a nonlinear crystal with phase matching condition, a pair of photons (signal and idler) is created at the same time with certain probability. We detect the photons in the signal beam with a single photon counting module (SPCM), while delaying those in the idler beam. Recently we have developed a fast electronic unit to control an optical shutter (a Pockels cell) placed to the optical output of the idler beam. When we detect a signal photon with the controlling electronic unit we are also able to open or close the fast optical shutter. Thus we can control which idler photons can propagate through the Pockels cell. So with this photon source we are able to program the number of photons in a certain time window. This controllable photon source that is able to generate a known number of photons with specified wavelength, direction, and polarization could be useful for applications in high-accuracy optical characterisation of photometric devices at the ultra-low intensities. This light source can also serve as a standard in testing of optical image intensifiers, night vision devices, and in the accurate measurement of spectral distribution of transmission and absorption in optical materials.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 18, 2006•2 citations

Measurement of quantum efficiency using correlated photon pairs and a single-detector technique

A. Czitrovszky, Alexander V. Sergienko, Peter J. Jani +1 more

A new approach is proposed to the calibration of photodetectors and the determination of the absolute value of the quantum efficiency of photon-counting photomultipliers using entangled-photon pairs. It is based on a new single-photodetector technique and a special modulation of the entangled-photon flux. The absolute values of the quantum efficiency have been determined for several photon-counting photomultipliers.

Metrologia•Oct 1, 2000•14 citations

Photon sources and detectors

Pieter Kok, Brendon W. Lovett

In optical quantum information processing, two of the most basic elements are the sources of quantum mechanical states of light, and the devices that can detect these states. In this chapter, we narrow this down to photon sources and photodetectors. We will describe first how detectors work, starting from abstract ideal detectors, via a complete description of realistic detectors in terms of POVMS, to a brief overview of current photodetectors. Subsequently, we will define what is a single-photon source, and how we can determine experimentally whether a source produces single photons or something else. Having laid down the ground rules, we will survey some of the most popular ways photons are produced in the laboratory. Finally, we take a look at the production of entangled photon sources and quantum non-demolition measurements of photons. A mathematical model of photodetectors Photodetectors are devices that produce a macroscopic signal when triggered by one or more photons. In the ideal situation, every photon that hits the detector contributes to the macroscopic signal, and there are no ‘ghost’ signals, or so-called dark counts. In this situation we can define two types of detector, namely the ‘photon-number detector’, and ‘detectors without number resolution’. First, the photon number detector is a (largely hypothetical) device that tells us how many photons there are in a given optical mode that is properly localized in space and time. This property is called ‘photon-number resolution’.

Cambridge University Press eBooks•Apr 22, 2010•0 citations

Measurement of quantum efficiency of avalanche photodetectors based on quantum two-photon field

A. Czitrovszky, Alexander V. Sergienko

A pair of rigorously correlated photons (biphotons) from parametric down conversion makes it possible to use them for measuring the absolute value of the quantum efficiency of the optical detectors, both in photon counting and in analog regimes, that does not use any calibrated standard light sources. Using this method the quantum efficiency of EG&G avalanche photodetectors was determined.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 19, 1998•3 citations

Absolute calibration of single-photon and multiplexed photon-number-resolving detectors

Lior Cohen, Y. Pilnyak, D. Istrati +3 more

Single-photon detectors are widely used in modern quantum optics experiments and applications. Like all detectors, it is important for these devices to be accurately calibrated. A single-photon detector is calibrated by determining its detection efficiency; the common method to measure this quantity requires comparison to another detector. Here, we suggest a method to measure the detection efficiency of a single-photon detector without requiring an external reference detector. Our method is valid for individual single-photon detectors as well as multiplexed detectors, which are known to be photon number resolving. The method exploits the even-number photon-statistics of a nonlinear source, as well as the nonlinear loss of a single-photon detector that occurs when multiple photons are incident simultaneously. We have analytically modeled multiplexed detectors and used the results to experimentally demonstrate the calibration of a single-photon detector without the need for an external reference detector.

arXiv:1711.03594•Physical Review A•Jul 5, 2018•27 citations

Experimental construction of a versatile four-photon source

Karol Bartkiewicz, Antonín Černoch, Karel Lemr

The paper discusses technical aspects of constructing a highly versatile multi-photon source. The source is able to generate up to four photons which is sufficient for a large number of quantum communications protocols. It can be set to generate separable, partially-entangled or maximally-entangled photon pairs with tunable amount of purity. Furthermore, the two generated pairs can be prepared in different quantum states. In this paper, we provide all the necessary information needed for construction and alignment of the source. To prove the working principle, we also provide results of thorough testing.

arXiv:1808.07073•Aug 21, 2018•0 citations
We designed a special light source generating a pre-determined number of photons taking advantage of our previous experimental results and calculations that establish a new approach to the calibration of photodetectors and determination of the absolute value of quantum efficiency of photon-counting photomultipliers using a single detector and entangled-photon pairs. This source is capable of generating a known number of photons of specified wavelength, in specified direction, and polarization for high-accuracy optical measurements (optical metrology) at the ultra-low intensities. The design and the modeling have been performed taking into account the main time characteristics of electronics, efficiency of detectors, parameters of the signal, losses, etc. The data evaluation system has been designed and tested; the assembly of the experimental set-up has been performed. Main parts of the optical and electronic system (generation of photon pairs, detectors, Pockels cells, etc.) have been tested. Such light source can be successfully applied in different areas of optical metrology, especially in photometry.
We have developed our pervious experimental setup using correlated photon pairs (to the calibration of photo detectors) to realize a controllable photon source. For the generation of such photon pairs we use the non-linear process of parametric down conversion. When a photon of the pump beam is incident to a nonlinear crystal with phase matching condition, a pair of photons (signal and idler) is created at the same time with certain probability. We detect the photons in the signal beam with a single photon counting module (SPCM), while delaying those in the idler beam. Recently we have developed a fast electronic unit to control an optical shutter (a Pockels cell) placed to the optical output of the idler beam. When we detect a signal photon with the controlling electronic unit we are also able to open or close the fast optical shutter. Thus we can control which idler photons can propagate through the Pockels cell. So with this photon source we are able to program the number of photons in a certain time window. This controllable photon source that is able to generate a known number of photons with specified wavelength, direction, and polarization could be useful for applications in high-accuracy optical characterisation of photometric devices at the ultra-low intensities. This light source can also serve as a standard in testing of optical image intensifiers, night vision devices, and in the accurate measurement of spectral distribution of transmission and absorption in optical materials.
In optical quantum information processing, two of the most basic elements are the sources of quantum mechanical states of light, and the devices that can detect these states. In this chapter, we narrow this down to photon sources and photodetectors. We will describe first how detectors work, starting from abstract ideal detectors, via a complete description of realistic detectors in terms of POVMS, to a brief overview of current photodetectors. Subsequently, we will define what is a single-photon source, and how we can determine experimentally whether a source produces single photons or something else. Having laid down the ground rules, we will survey some of the most popular ways photons are produced in the laboratory. Finally, we take a look at the production of entangled photon sources and quantum non-demolition measurements of photons. A mathematical model of photodetectors Photodetectors are devices that produce a macroscopic signal when triggered by one or more photons. In the ideal situation, every photon that hits the detector contributes to the macroscopic signal, and there are no ‘ghost’ signals, or so-called dark counts. In this situation we can define two types of detector, namely the ‘photon-number detector’, and ‘detectors without number resolution’. First, the photon number detector is a (largely hypothetical) device that tells us how many photons there are in a given optical mode that is properly localized in space and time. This property is called ‘photon-number resolution’.
Single-photon detectors are widely used in modern quantum optics experiments and applications. Like all detectors, it is important for these devices to be accurately calibrated. A single-photon detector is calibrated by determining its detection efficiency; the common method to measure this quantity requires comparison to another detector. Here, we suggest a method to measure the detection efficiency of a single-photon detector without requiring an external reference detector. Our method is valid for individual single-photon detectors as well as multiplexed detectors, which are known to be photon number resolving. The method exploits the even-number photon-statistics of a nonlinear source, as well as the nonlinear loss of a single-photon detector that occurs when multiple photons are incident simultaneously. We have analytically modeled multiplexed detectors and used the results to experimentally demonstrate the calibration of a single-photon detector without the need for an external reference detector.
The paper discusses technical aspects of constructing a highly versatile multi-photon source. The source is able to generate up to four photons which is sufficient for a large number of quantum communications protocols. It can be set to generate separable, partially-entangled or maximally-entangled photon pairs with tunable amount of purity. Furthermore, the two generated pairs can be prepared in different quantum states. In this paper, we provide all the necessary information needed for construction and alignment of the source. To prove the working principle, we also provide results of thorough testing.