Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Zeitschrift für Naturforschung A

Measurement of a Weak Value

Randall G. Hulet, Nicholas W. M. Ritchie, J. G. Story

Published Feb 1, 1997• 0 citations
Publisher

Abstract

Abstract "Weak measurements" are measurements in which the coupling between the measuring device and the observable to be measured is so weak that the eigenvalues of the observable are not resolved. Under certain circumstances the corresponding eigenfunctions can be made to interfere, producing a measurement result which is outside the allowed range of the observable's eigenvalues. We present the first measurement of this so-called "weak value" using an optical experiment. In our experiment, the small displacement between the two orthogonally polarized components of a laser beam passed through a birefringence crystal is measured. We use a numerical simulation to show that this phenomenon may be practical for detecting and amplifying small effects.

DOI
10.1515/zna-1997-1-210

Related papers

Measuring the weak value in an optical experiment

Nicholas W. M. Ritchie

The first experimental realization of a measurement of the weak value of a variable, a concept recently introduced by Aharonov, Albert and Vaidman, is presented. Weak measurements (measurements of a weak value) address the situation in which the separation of the eigenvalues caused by a weakly interacting measurement device is small compared to the width of the distribution of the individual eigenvalues. By appropriate choice of the pre- and post-selected state it is possible that the overlapping eigenvalues will interfere producing a value outside the range of eigenvalues. We demonstrate that the weak value is a practical method of amplifying and resolving the separation between overlapping eigenvalues in an optical experiment proposed by Duck, Stevenson and Sudarshan. In this experiment a birefringent crystal spatially separates two linear polarization components of a Gaussian laser beam by a distance much smaller than the beam waist.

•Jan 1, 1991•0 citations

Realization of a measurement of a ‘‘weak value’’

Nicholas W. M. Ritchie, J. G. Story, Randall G. Hulet

We present the first realization of a measurement of a ``weak value,'' a concept recently introduced by Aharonov, Albert, and Vaidman (AAV). Our experiment uses a birefringent crystal to separate the two linear-polarization components of a laser beam by a distance small compared to the laser-beam waist. This ``weak measurement'' is followed by a strong measurement which translates the centroid of the beam by a distance far larger than the birefringence-induced separation. In addition, we present data corresponding to orthogonal initial and final states, for which the weak value is not defined. This interference effect may have application in the amplification and detection of weak effects.

Physical Review Letters•Mar 4, 1991•594 citations

Weak Measurements in Nano-optics

Niladri Modak, Ankit Kumar Singh, Shyamal Guchhait +3 more

Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.

Current Nanomaterials•Jul 24, 2020•5 citations

Roadmap on Weak Measurements in Optics

Ritwik Dhara, Niladri Modak, Shyamal Guchhait +1 more

Abstract Even though weak measurements and weak value amplification (WVA) are founded on the principles of quantum mechanics and quantum measurements, these have found widespread applications in optics due to their inherent origin in wave interference. Besides their use in addressing foundational questions of quantum mechanics or for resolving quantum paradoxes, weak measurements and WVA have thus been used for numerous metrological applications, e.g., quantification of small optical beam displacement, tiny angular rotation, determination of extremely small phase shifts, spectral shifts, unraveling weak fundamental optical effects, improved optical imaging, amplifying weak signal and extracting small physical parameters and so forth. In this review, after providing the mathematical foundation of weak measurement and WVA, some of the metrological applications of weak measurements in the classical optics domain are briefly summarized, and the controversies and debates on the potential advantages of WVA in the estimation and detection of weak signal are discussed, and the interferometric philosophy of WVA is elucidated. The experimental weak measurement and WVA schemes in the domain of quantum optics are also discussed and highlighted the new perspectives and emerging trends of weak measurements in both the classical and quantum optics domain and their prospects in the development of next‐generation ultra‐sensitive optical devices.

Advanced Physics Research•Dec 19, 2024•7 citations

Stokes vector characterization by strongly measuring weak values

C. Montenegro La Torre, M. Jara, Jean Paul Marrou +1 more

We report the implementation of a non-standard procedure to perform Stokes polarimetry, which was recently proposed by considering weak value measurements. Our procedure is not restricted to weak measurements but applies for both weak and strong couplings between the observable being measured; the polarization (spin) vector; and the measuring device, the "pointer." In optics, the polarization-pointer coupling is usually implemented with a birefringent crystal. This applies in the weak coupling regime. We overcame this limitation by using an alternative setup in which one can go from weak to strong couplings by tuning a moveable mirror. We carried out our proof-of-concept experiments with a laser beam, the image of which was recorded and processed on a charge-coupled device. Our results illustrate that some concepts, originally introduced in a quantum context, in fact refer to properties that are common to both quantum and classical phenomena.

Journal of the Optical Society of America A•Mar 12, 2024•2 citations

Revisiting weak values through non-normality

Lorena Ballesteros Ferraz, Riccardo Muolo, Yves Caudano +1 more

Abstract Quantum measurement is one of the most fascinating and discussed phenomena in quantum physics, due to the impact on the system of the measurement action and the resulting interpretation issues. Scholars proposed weak measurements to amplify measured signals by exploiting a quantity called a weak value, but also to overcome philosophical difficulties related to the system perturbation induced by the measurement process. The method finds many applications and raises many philosophical questions as well, especially about the proper interpretation of the observations. In this paper, we show that any weak value can be expressed as the expectation value of a suitable non-normal operator. We propose a preliminary explanation of their anomalous and amplification behavior based on the theory of non-normal matrices and their link with non-normality: the weak value is different from an eigenvalue when the operator involved in the expectation value is non-normal. Our study paves the way for a deeper understanding of the measurement phenomenon, helps the design of experiments, and it is a call for collaboration to researchers in both fields to unravel new quantum phenomena induced by non-normality.

arXiv:2306.01392•Journal of Physics A Mathematical and Theoretical•Oct 18, 2023•4 citations
Abstract "Weak measurements" are measurements in which the coupling between the measuring device and the observable to be measured is so weak that the eigenvalues of the observable are not resolved. Under certain circumstances the corresponding eigenfunctions can be made to interfere, producing a measurement result which is outside the allowed range of the observable's eigenvalues. We present the first measurement of this so-called "weak value" using an optical experiment. In our experiment, the small displacement between the two orthogonally polarized components of a laser beam passed through a birefringence crystal is measured. We use a numerical simulation to show that this phenomenon may be practical for detecting and amplifying small effects.
The first experimental realization of a measurement of the weak value of a variable, a concept recently introduced by Aharonov, Albert and Vaidman, is presented. Weak measurements (measurements of a weak value) address the situation in which the separation of the eigenvalues caused by a weakly interacting measurement device is small compared to the width of the distribution of the individual eigenvalues. By appropriate choice of the pre- and post-selected state it is possible that the overlapping eigenvalues will interfere producing a value outside the range of eigenvalues. We demonstrate that the weak value is a practical method of amplifying and resolving the separation between overlapping eigenvalues in an optical experiment proposed by Duck, Stevenson and Sudarshan. In this experiment a birefringent crystal spatially separates two linear polarization components of a Gaussian laser beam by a distance much smaller than the beam waist.
We present the first realization of a measurement of a ``weak value,'' a concept recently introduced by Aharonov, Albert, and Vaidman (AAV). Our experiment uses a birefringent crystal to separate the two linear-polarization components of a laser beam by a distance small compared to the laser-beam waist. This ``weak measurement'' is followed by a strong measurement which translates the centroid of the beam by a distance far larger than the birefringence-induced separation. In addition, we present data corresponding to orthogonal initial and final states, for which the weak value is not defined. This interference effect may have application in the amplification and detection of weak effects.
Background: Weak measurement involves weak coupling between the system and the measuring device (pointer) enables large amplification and high precision measurement of small physical parameters. The outcome of this special measurement procedure involving nearly mutually orthogonal pre- and post-selection of states in such weakly interacting systems leads to weak value that can become exceedingly large and lie outside the eigenvalue spectrum of the measured observable. This unprecedented ability of weak value amplification of small physical parameters has been successfully exploited for various metrological applications in the optical domain and beyond. Even though it is a quantum mechanical concept, it can be understood using the classical electromagnetic theory of light and thus can be realized in classical optics. Objective: Here, we briefly review the basic concepts of weak measurement and weak value amplification, provide illustrative examples of its implementation in various optical domains. The applications involve measuring ultra-sensitive beam deflections, high precision measurements of angular rotation, phase shift, temporal shift, frequency shift and so forth, and expand this extraordinary concept in the domain of nano-optics and plasmonics. Methods: In order to perform weak value amplification, we have used Gaussian beam and spectral response as the pointer subsequently. The polarization state associated with the pointer is used as pre and post-selection device. Results: We reveal the weak value amplification of sub-wavelength optical effects namely the Goos-Hänchen shift and the spin hall shift. Further, we demonstrate weak measurements using spectral line shape of resonance as a natural pointer, enabling weak value amplification beyond the conventional limit, demonstrating natural weak value amplification in plasmonic Fano resonances and so forth. The discussed concepts could have useful implications in various nano-optical systems to amplify tiny signals or effects. Conclusion: The emerging prospects of weak value amplification towards the development of novel optical weak measurement devices for metrological applications are extensively discussed.
Abstract Even though weak measurements and weak value amplification (WVA) are founded on the principles of quantum mechanics and quantum measurements, these have found widespread applications in optics due to their inherent origin in wave interference. Besides their use in addressing foundational questions of quantum mechanics or for resolving quantum paradoxes, weak measurements and WVA have thus been used for numerous metrological applications, e.g., quantification of small optical beam displacement, tiny angular rotation, determination of extremely small phase shifts, spectral shifts, unraveling weak fundamental optical effects, improved optical imaging, amplifying weak signal and extracting small physical parameters and so forth. In this review, after providing the mathematical foundation of weak measurement and WVA, some of the metrological applications of weak measurements in the classical optics domain are briefly summarized, and the controversies and debates on the potential advantages of WVA in the estimation and detection of weak signal are discussed, and the interferometric philosophy of WVA is elucidated. The experimental weak measurement and WVA schemes in the domain of quantum optics are also discussed and highlighted the new perspectives and emerging trends of weak measurements in both the classical and quantum optics domain and their prospects in the development of next‐generation ultra‐sensitive optical devices.
We report the implementation of a non-standard procedure to perform Stokes polarimetry, which was recently proposed by considering weak value measurements. Our procedure is not restricted to weak measurements but applies for both weak and strong couplings between the observable being measured; the polarization (spin) vector; and the measuring device, the "pointer." In optics, the polarization-pointer coupling is usually implemented with a birefringent crystal. This applies in the weak coupling regime. We overcame this limitation by using an alternative setup in which one can go from weak to strong couplings by tuning a moveable mirror. We carried out our proof-of-concept experiments with a laser beam, the image of which was recorded and processed on a charge-coupled device. Our results illustrate that some concepts, originally introduced in a quantum context, in fact refer to properties that are common to both quantum and classical phenomena.
Abstract Quantum measurement is one of the most fascinating and discussed phenomena in quantum physics, due to the impact on the system of the measurement action and the resulting interpretation issues. Scholars proposed weak measurements to amplify measured signals by exploiting a quantity called a weak value, but also to overcome philosophical difficulties related to the system perturbation induced by the measurement process. The method finds many applications and raises many philosophical questions as well, especially about the proper interpretation of the observations. In this paper, we show that any weak value can be expressed as the expectation value of a suitable non-normal operator. We propose a preliminary explanation of their anomalous and amplification behavior based on the theory of non-normal matrices and their link with non-normality: the weak value is different from an eigenvalue when the operator involved in the expectation value is non-normal. Our study paves the way for a deeper understanding of the measurement phenomenon, helps the design of experiments, and it is a call for collaboration to researchers in both fields to unravel new quantum phenomena induced by non-normality.