Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Experimental and Theoretical Physics Letters

A new escape channel for ultracold neutrons in traps

Peter W. Geltenbort, Валерий Викторович Несвижевский, D. G. Kartashov, Е. В. Лычагин, Al. Yu. Muzychka, G. V. Nekhaev, Valery N. Shvetsov, Alexander V. Strelkov, А. Г. Харитонов, Anatolii P. Serebrov, R. R. Tal'Daev, J. M. Pendlebury

Published Aug 1, 1999• 9 citations
Publisher

Abstract

A surprising new escape channel for ultracold neutrons (UCNs) in traps was reported recently. It could be relevant to the long-standing puzzle of the “too high” loss rate of UCNs from traps, which has yet to be completely understood and eliminated. In the present work we positively identify the new phenomenon and investigate it in detail. The escape of UCNs from traps is due to rare events in which their energy undergoes a small increase (∼10 −7 eV). The reason for such an energy gain and its impact on the physics of UCN storage is still to be investigated.

DOI
10.1134/1.568148

Related papers

First ever storage of ultracold neutrons in a magnetic trap made of permanent magnets

В. Ф. Ежов, A. Z. Andreev, A.A. Glushkov +13 more

Further improvement in the accuracy of any neutron lifetime experiment by means of ultracold neutrons (UCN) in material bottles is limited due to unavoidable systematic effects when the UCN are reflected from the walls. However, such effects can be excluded in principle if magnetic trapping of UCN is used. The storage of UCN in a small magnetic trap made of permanent magnets was demonstrated for the first time ever. The measured storage time in this feasibility study was (882 ± 16) s. At this level of accuracy no depolarization was observed.

Journal of Research of the National Institute of Standards and Technology•Jul 1, 2005•23 citations

Resonance capture by hydrogenous impurities and losses of ultracold neutrons in solid material traps

G.S. Danilov

The capture of trapped ultracold neutrons (UCNs) by closed hydrogenous impurities within a solid coating of the trap is discussed as a possible cause of observed anomalously large losses of UCNs in solid material UCN traps. Then significant losses of UCNs arise only if resonances occur in the UCN-impurity scattering amplitude. For a large size impurity, higher partial waves in the UCN-impurity interaction are important, and they are taken into account in the present paper. The method of the calculation is applicable to irregular shape impurities as well. A small distortion of an impurity shape, if it splits the resonance, can increase the UCN losses by a few times. UCN losses in the beryllium trap are calculated assuming they are due to the UCN capture by ice spherical impurities within the coating of the trap walls. Both s- and p-wave resonances contribute significantly to the UCN losses considered. As an example, observed anomalous large UCN losses are achieved if the average radius of the impurity is about 600 Angstroms and the impurity density is about 3*10^{14}/cm^3. A distortion of the spherical shape of the impurity could increase the UCN losses and therefore decrease the impurity density.

arXiv:0903.0458•Mar 3, 2009•0 citations

Storage of ultracold neutrons in a volume coated with diamondlike carbon

F. Atchison, B. Blau, M. Daum +17 more

Ultracold neutrons (UCN) with energy up to the Fermi potential were stored for the first time in a volume coated with diamondlike carbon. As a function of the UCN energy and wall temperature of the storage volume, we measured the wall loss parameter \ensuremath{\eta} and obtained $\ensuremath{\eta}=(3.1\ifmmode\pm\else\textpm\fi{}0.9)\ifmmode\cdot\else\textperiodcentered\fi{}{10}^{\ensuremath{-}4}$ at $T=290$ K and $\ensuremath{\eta}=(1.8\ifmmode\pm\else\textpm\fi{}0.2)\ifmmode\cdot\else\textperiodcentered\fi{}{10}^{\ensuremath{-}4}$ at $T=115$ K.

Physical Review C•Nov 9, 2006•31 citations

Cooling of ultracold neutrons during their long storage in a trap

L. Bondarenko, E. Korobkina, V. I. Morozov +3 more

We have observed the cooling of ultracold neutrons during their long storage in a trap, with a probability estimated as 1×10 −6 /reflection and with an energy transfer of about 3 neV.

Journal of Experimental and Theoretical Physics Letters•Nov 1, 1998•15 citations

Quasielastic scattering of ultracold neutrons as possible reason for their energy spreading during long storage in closed traps

Y.N. Pokotilovski

The European Physical Journal B•Mar 1, 1999•13 citations

Interaction of ultracold neutrons with liquid surface modes as a possible reason for neutron energy spread during long storage in fluid wall traps

Yu. N. Pokotilovski

Physics Letters A•May 1, 1999•24 citations
A surprising new escape channel for ultracold neutrons (UCNs) in traps was reported recently. It could be relevant to the long-standing puzzle of the “too high” loss rate of UCNs from traps, which has yet to be completely understood and eliminated. In the present work we positively identify the new phenomenon and investigate it in detail. The escape of UCNs from traps is due to rare events in which their energy undergoes a small increase (∼10 −7 eV). The reason for such an energy gain and its impact on the physics of UCN storage is still to be investigated.
Further improvement in the accuracy of any neutron lifetime experiment by means of ultracold neutrons (UCN) in material bottles is limited due to unavoidable systematic effects when the UCN are reflected from the walls. However, such effects can be excluded in principle if magnetic trapping of UCN is used. The storage of UCN in a small magnetic trap made of permanent magnets was demonstrated for the first time ever. The measured storage time in this feasibility study was (882 ± 16) s. At this level of accuracy no depolarization was observed.
The capture of trapped ultracold neutrons (UCNs) by closed hydrogenous impurities within a solid coating of the trap is discussed as a possible cause of observed anomalously large losses of UCNs in solid material UCN traps. Then significant losses of UCNs arise only if resonances occur in the UCN-impurity scattering amplitude. For a large size impurity, higher partial waves in the UCN-impurity interaction are important, and they are taken into account in the present paper. The method of the calculation is applicable to irregular shape impurities as well. A small distortion of an impurity shape, if it splits the resonance, can increase the UCN losses by a few times. UCN losses in the beryllium trap are calculated assuming they are due to the UCN capture by ice spherical impurities within the coating of the trap walls. Both s- and p-wave resonances contribute significantly to the UCN losses considered. As an example, observed anomalous large UCN losses are achieved if the average radius of the impurity is about 600 Angstroms and the impurity density is about 3*10^{14}/cm^3. A distortion of the spherical shape of the impurity could increase the UCN losses and therefore decrease the impurity density.
Ultracold neutrons (UCN) with energy up to the Fermi potential were stored for the first time in a volume coated with diamondlike carbon. As a function of the UCN energy and wall temperature of the storage volume, we measured the wall loss parameter \ensuremath{\eta} and obtained $\ensuremath{\eta}=(3.1\ifmmode\pm\else\textpm\fi{}0.9)\ifmmode\cdot\else\textperiodcentered\fi{}{10}^{\ensuremath{-}4}$ at T=290T=290T=290 K and $\ensuremath{\eta}=(1.8\ifmmode\pm\else\textpm\fi{}0.2)\ifmmode\cdot\else\textperiodcentered\fi{}{10}^{\ensuremath{-}4}$ at T=115T=115T=115 K.