Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Realization of a nonlinear interferometer with parametric amplifiers

Jietai Jing, Cunjin Liu, Zhifan Zhou, Z. Y. Ou, Weiping Zhang

Published Jul 4, 2011• 197 citations
Publisher

Abstract

We construct an interferometer with parametric amplifiers as beam splitters. Because of the gain in the parametric amplifiers, the maximum output intensity of the interferometer can be much bigger than the input intensity as well as the intensity inside the interferometer (the phase sensing intensity). We find that the fringe intensity depends quadratically on the intensity of the phase sensing field at high gain. This type of nonlinear interferometer has better sensitivity than the traditional linear interferometer made of beam splitters with the same phase sensing intensity.

DOI
10.1063/1.3606549

Related papers

Enhancement of the phase-measurement sensitivity beyond the standard quantum limit by a nonlinear interferometer

Z. Y. Ou

A nonlinear interferometer uses nonlinear elements as beam splitters to split and to recombine optical waves for interference. As a result, the interference fringe size has a nonlinear dependence on the intensity of the field for phase sensing and leads to an enhanced phase signal. In this paper, a practical scheme of nonlinear interferometry for precision phase measurement is analyzed with parametric amplifiers as the nonlinear beam splitters. It is found that the signal due to phase shift is enhanced by a factor of the amplification gain as compared to a linear interferometer with the same phase-sensing light intensity while the quantum noise is kept at the vacuum level, thus, effectively increasing the signal-to-noise ratio (SNR) beyond the standard quantum limit. Furthermore, the scheme is not as sensitive to the detection loss as the linear scheme with a squeezed state for noise reduction. However, losses inside the interferometer limit the enhancement factor in SNR. We apply the concept to a Michelson interferometer but with parametric amplifiers involved for gravitational-wave detection. We find that effective power is increased by the gain of the amplifiers without actually increasing the cycling power inside the interferometer. Furthermore, the full benefits with squeezed input and variational output or the combination of a quantum nondemolition interferometer for sensitivity beyond the standard quantum limit apply here with even better results. Such a nonlinear interferometer will find wide applications in precision measurements.

Physical Review A•Feb 14, 2012•195 citations

Experimental implementation of a nonlinear beamsplitter based on a phase-sensitive parametric amplifier

Yami Fang, Jingliang Feng, Leiming Cao +2 more

Beamsplitters have played an important role in quantum optics experiments. They are often used to split and combine two beams, especially in the construct of an interferometer. In this letter, we experimentally implement a nonlinear beamsplitter using a phase-sensitive parametric amplifier, which is based on four-wave mixing in hot rubidium vapor. Here we show that, despite the different frequencies of the two input beams, the output ports of the nonlinear beamsplitter exhibit interference phenomena. We make measurements of the interference fringe visibility and study how various parameters, such as the intensity gain of the amplifier, the intensity ratio of the two input beams, and the one and two photon detunings, affect the behavior of the nonlinear beamsplitter. It may find potential applications in quantum metrology and quantum information processing.

Applied Physics Letters•Mar 28, 2016•15 citations

Hybrid interferometer with nonlinear four-wave mixing process and linear beam splitter

Shengshuai Liu, Jietai Jing

Optical interferometer has played an important role in optics. Up to now, many kinds of interferometers have been realized and found their applications. In this letter, we experimentally construct an interferometer by using parametric amplifier as a wave splitter and beam splitter as a wave combiner. We make measurements of interference fringes and explore the relationships between the interference visibility of the interferometer and various system parameters, such as the gain of the parametric amplifier, the one-photon detuning and the temperature of the Rb-85 vapor cell.

Optics Express•Jun 27, 2017•4 citations

Nonlinear SU(1,1) interferometers with an on-chip parametric amplifier

Yue Li, Xiaotian Zhu, Jianmin Wang +4 more

SU(1,1) interferometers use two active parametric amplifiers to replace passive beam splitters of traditional interferometers for wave splitting and superposition. These interferometers involve quantum entangled signal and idler fields and possess a number of advantages over traditional interferometers. Here, we investigate a variant of the SU(1,1) interferometer by using only one parametric amplifier but with either one or both of the signal and idler fields fed back to the same parametric amplifier. Such a geometry is used to accommodate an on-chip micro-ring optical parametric oscillator made of high-index silica glass. An interference fringe is observed, and quantum noise reduction of 4-dB due to destructive quantum interference is measured in the output off the chip. Such an integrated device has potential applications in on-chip precision phase sensing.

Applied Physics Letters•Apr 21, 2025•1 citation

Quantum metrology with parametric amplifier-based photon correlation interferometers

Florian Hudelist, Jia Kong, Cunjin Liu +3 more

Conventional interferometers usually utilize beam splitters for wave splitting and recombination. These interferometers are widely used for precision measurement. Their sensitivity for phase measurement is limited by the shot noise, which can be suppressed with squeezed states of light. Here we study a new type of interferometer in which the beam splitting and recombination elements are parametric amplifiers. We observe an improvement of 4.1±0.3 dB in signal-to-noise ratio compared with a conventional interferometer under the same operating condition, which is a 1.6-fold enhancement in rms phase measurement sensitivity beyond the shot noise limit. The improvement is due to signal enhancement. Combined with the squeezed state technique for shot noise suppression, this interferometer promises further improvement in sensitivity. Furthermore, because nonlinear processes are involved in this interferometer, we can couple a variety of different waves and form new types of hybrid interferometers, opening a door for many applications in metrology. Interferometers play a key role in precision measurements and metrology. Here, the authors demonstrate a new type of interferometer that replaces the standard beam splitter elements with parametric amplifiers, which provides enhanced performance compared with a Mach–Zehnder interferometer.

Nature Communications•Jan 29, 2014•438 citations

Experimental investigation of the visibility dependence in a nonlinear interferometer using parametric amplifiers

Jia Kong, Jietai Jing, Hailong Wang +3 more

Two four-wave mixing processes have been employed to experimentally construct a nonlinear interferometer [Jing et al., Appl. Phys. Lett. 99, 011110 (2011)], which has a better phase sensitivity than the traditional linear interferometer. For its applications in quantum measurement, interference fringe visibility can significantly affect the quantum detection efficiency. In this letter, we study how various parameters, such as the pump power, the one-photon detuning, and the two-photon detuning, influence the visibility of nonlinear interferometer. We find that the visibility greater than 0.9 can be achieved for large range of system parameters.

Applied Physics Letters•Jan 7, 2013•44 citations
We construct an interferometer with parametric amplifiers as beam splitters. Because of the gain in the parametric amplifiers, the maximum output intensity of the interferometer can be much bigger than the input intensity as well as the intensity inside the interferometer (the phase sensing intensity). We find that the fringe intensity depends quadratically on the intensity of the phase sensing field at high gain. This type of nonlinear interferometer has better sensitivity than the traditional linear interferometer made of beam splitters with the same phase sensing intensity.
A nonlinear interferometer uses nonlinear elements as beam splitters to split and to recombine optical waves for interference. As a result, the interference fringe size has a nonlinear dependence on the intensity of the field for phase sensing and leads to an enhanced phase signal. In this paper, a practical scheme of nonlinear interferometry for precision phase measurement is analyzed with parametric amplifiers as the nonlinear beam splitters. It is found that the signal due to phase shift is enhanced by a factor of the amplification gain as compared to a linear interferometer with the same phase-sensing light intensity while the quantum noise is kept at the vacuum level, thus, effectively increasing the signal-to-noise ratio (SNR) beyond the standard quantum limit. Furthermore, the scheme is not as sensitive to the detection loss as the linear scheme with a squeezed state for noise reduction. However, losses inside the interferometer limit the enhancement factor in SNR. We apply the concept to a Michelson interferometer but with parametric amplifiers involved for gravitational-wave detection. We find that effective power is increased by the gain of the amplifiers without actually increasing the cycling power inside the interferometer. Furthermore, the full benefits with squeezed input and variational output or the combination of a quantum nondemolition interferometer for sensitivity beyond the standard quantum limit apply here with even better results. Such a nonlinear interferometer will find wide applications in precision measurements.
Beamsplitters have played an important role in quantum optics experiments. They are often used to split and combine two beams, especially in the construct of an interferometer. In this letter, we experimentally implement a nonlinear beamsplitter using a phase-sensitive parametric amplifier, which is based on four-wave mixing in hot rubidium vapor. Here we show that, despite the different frequencies of the two input beams, the output ports of the nonlinear beamsplitter exhibit interference phenomena. We make measurements of the interference fringe visibility and study how various parameters, such as the intensity gain of the amplifier, the intensity ratio of the two input beams, and the one and two photon detunings, affect the behavior of the nonlinear beamsplitter. It may find potential applications in quantum metrology and quantum information processing.
Optical interferometer has played an important role in optics. Up to now, many kinds of interferometers have been realized and found their applications. In this letter, we experimentally construct an interferometer by using parametric amplifier as a wave splitter and beam splitter as a wave combiner. We make measurements of interference fringes and explore the relationships between the interference visibility of the interferometer and various system parameters, such as the gain of the parametric amplifier, the one-photon detuning and the temperature of the Rb-85 vapor cell.
SU(1,1) interferometers use two active parametric amplifiers to replace passive beam splitters of traditional interferometers for wave splitting and superposition. These interferometers involve quantum entangled signal and idler fields and possess a number of advantages over traditional interferometers. Here, we investigate a variant of the SU(1,1) interferometer by using only one parametric amplifier but with either one or both of the signal and idler fields fed back to the same parametric amplifier. Such a geometry is used to accommodate an on-chip micro-ring optical parametric oscillator made of high-index silica glass. An interference fringe is observed, and quantum noise reduction of 4-dB due to destructive quantum interference is measured in the output off the chip. Such an integrated device has potential applications in on-chip precision phase sensing.
Conventional interferometers usually utilize beam splitters for wave splitting and recombination. These interferometers are widely used for precision measurement. Their sensitivity for phase measurement is limited by the shot noise, which can be suppressed with squeezed states of light. Here we study a new type of interferometer in which the beam splitting and recombination elements are parametric amplifiers. We observe an improvement of 4.1±0.3 dB in signal-to-noise ratio compared with a conventional interferometer under the same operating condition, which is a 1.6-fold enhancement in rms phase measurement sensitivity beyond the shot noise limit. The improvement is due to signal enhancement. Combined with the squeezed state technique for shot noise suppression, this interferometer promises further improvement in sensitivity. Furthermore, because nonlinear processes are involved in this interferometer, we can couple a variety of different waves and form new types of hybrid interferometers, opening a door for many applications in metrology. Interferometers play a key role in precision measurements and metrology. Here, the authors demonstrate a new type of interferometer that replaces the standard beam splitter elements with parametric amplifiers, which provides enhanced performance compared with a Mach–Zehnder interferometer.
Two four-wave mixing processes have been employed to experimentally construct a nonlinear interferometer [Jing et al., Appl. Phys. Lett. 99, 011110 (2011)], which has a better phase sensitivity than the traditional linear interferometer. For its applications in quantum measurement, interference fringe visibility can significantly affect the quantum detection efficiency. In this letter, we study how various parameters, such as the pump power, the one-photon detuning, and the two-photon detuning, influence the visibility of nonlinear interferometer. We find that the visibility greater than 0.9 can be achieved for large range of system parameters.