Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Letters

Active phase stabilization in Fourier-transform two-dimensional infrared spectroscopy

Victor V. Volkov, Roland Schanz, Peter M. Hamm

Published Aug 1, 2005• 103 citations
Publisher

Abstract

A scheme for active phase stabilization and absolute positioning in Fourier-transform two-dimensional (2D) IR spectroscopy is presented. The position accuracy is better than 20 nm(rms) corresponding to lambda/250 at 5 microm, which significantly improves the quality of Fourier-transform 2D IR spectra. Phase stabilization is added to a standard photon echo setup in a way that does not impair the flexibility of the experiment and the control over IR pulse parameters.

DOI
10.1364/ol.30.002010

Related papers

Coherent Control in 2D Fourier Transform Optical Spectroscopy

Jongseok Lim, Jaeuk Kim, Han-gyeol Lee +1 more

Using individually shaped three pulses in 2D Fourier transform optical spectroscopy, we retrieve and coherently control the amplitude and phase of the two-photon transition between 5P1/2 and 5P3/2 levels in atomic Rubidium.

Nonlinear Optics•Jan 1, 2011•0 citations

Coherently-controlled two-dimensional photon echo electronic spectroscopy

Valentyn I. Prokhorenko, Alexei Halpin, R. J. Dwayne Miller

Optical two-dimensional photon-echo spectroscopy is realized with shaped excitation pulses, allowing coherent control of twodimensional spectra. This development enables probing of state-selective quantum decoherence and phase/time sensitive couplings between states. The coherently-controlled two-dimensional photon-echo spectrometer with two pulse shapers is based on a passively stabilized four-beam interferometer with diffractive optic, and allows heterodyne detection of signals with a long-term phase stability of approximately Lambda/100. The two-dimensional spectra of Rhodamine 101 in a methanol solution, measured with unshaped and shaped pulses, exhibit significant differences. We observe in particular, the appearance of fine structure in the spectra obtained using shaped excitation pulses.

Optics Express•May 27, 2009•79 citations

Quantum Fourier Transform Infrared Spectroscopy: Evaluation, Benchmarking, and Prospects

Paul Gattinger, Andreas Wolfgang Schell, Sven Ramelow +2 more

Sensing with undetected photons has enabled new, unconventional approaches to Fourier transform infrared spectroscopy (FT-IR). Leveraging properties of non-degenerate entangled photon pairs, mid-infrared (mid-IR) information can be accessed in the near-infrared (near-IR) spectral domain to perform mid-IR spectroscopy with silicon-based detection schemes. Here, we address practical aspects of vibrational spectroscopy with undetected photons using a quantum FT-IR (QFT-IR) implementation. The system operates in the spectral range from around 3000 cm −1 to 2380 cm −1 (detection at around 12 500 cm −1 ) and possesses only 68 pW of mid-IR probing power for spectroscopic measurements with a power-dependence of the signal-to-noise ratio of 1.5 × 10 5 mW −1/2 . We evaluate the system’s short- and long-term stability and experimentally compare it to a commercial FT-IR instrument using Allan–Werle plots to benchmark our QFT-IR implementation’s overall performance and stability. In addition, comparative qualitative spectroscopic measurements of polymer thin films are performed using the QFT-IR spectrometer and a commercial FT-IR with identical resolution and integration times. Our results show under which conditions QFT-IR can practically be competitive or potentially outperform conventional FT-IR technology.

arXiv:2503.13233•Applied Spectroscopy•May 21, 2025•7 citations

Advances in optical two-dimensional spectroscopy applied to the study of semiconductor and atomic systems

Alan D. Bristow, Xingcan Dai, D. Karaiskaj +2 more

Electronic structure and dynamics are captured by optical 2D-Fourier-transform (2DFT) spectroscopy, which tracks the phase of the nonlinear signal during two time delays of a multi-pulse excitation sequence. These Fourier-transformed spectra separate and isolate overlapping and competing contributions to the coherent response. We have developed an ultra-stable platform consisting of nested interferometers with active phase control, allowing for exploration of single- and two-quantum coherences. Phase-resolved spectra are retrieved by all-optical determination of experimental phase ambiguities. GaAs quantum wells show suppression of many-body interactions in cross-linear polarized 2DFT spectra and many-body two-quantum coherences. Potassium vapor also shows unexpected two-quantum coherences.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 11, 2010•0 citations

Compact phase-stable design for single- and double-quantum two-dimensional electronic spectroscopy

Alexandra Nemeth, Jaroslaw Sperling, Jürgen Hauer +2 more

We report a compact, easy to align, and passively phase-stabilized setup for recording two-dimensional (2D) electronic spectra in three different phase-matching directions in the boxcar geometry. Passive phase stabilization is achieved by a diffractive optical element, the use of refractive optics for introducing pulse delays, and the use of common optics for all pulses. Representative 2D spectra correlating single- and double-quantum coherences in a molecular aggregate are presented.

Optics Letters•Oct 21, 2009•41 citations

Spectral resolution of quantum Fourier transform infrared spectroscopy using pulsed laser excitation

Jasleen Kaur, Yu Mukai, Ryo Okamoto +1 more

In recent years, nonlinear quantum interferometry has been widely explored for applications like spectroscopy, optical coherence tomography, and imaging [1]. Quantum infrared spectroscopy (QIRS) uses quantum interference of generation processes of frequency-entangled visible-IR photon pairs to perform infrared spectroscopy using visible light sources and silicon-based detectors [2]. This technique utilizes a nonlinear quantum interferometer configuration where the generated IR photons pass through the sample, and the correlated visible photons are detected. The change in the detected visible photon flux with and without the sample helps extract the complex transmittance of the sample in the IR region.

JSAP-OSA Joint Symposia•Jan 1, 2024•0 citations
A scheme for active phase stabilization and absolute positioning in Fourier-transform two-dimensional (2D) IR spectroscopy is presented. The position accuracy is better than 20 nm(rms) corresponding to lambda/250 at 5 microm, which significantly improves the quality of Fourier-transform 2D IR spectra. Phase stabilization is added to a standard photon echo setup in a way that does not impair the flexibility of the experiment and the control over IR pulse parameters.
Optical two-dimensional photon-echo spectroscopy is realized with shaped excitation pulses, allowing coherent control of twodimensional spectra. This development enables probing of state-selective quantum decoherence and phase/time sensitive couplings between states. The coherently-controlled two-dimensional photon-echo spectrometer with two pulse shapers is based on a passively stabilized four-beam interferometer with diffractive optic, and allows heterodyne detection of signals with a long-term phase stability of approximately Lambda/100. The two-dimensional spectra of Rhodamine 101 in a methanol solution, measured with unshaped and shaped pulses, exhibit significant differences. We observe in particular, the appearance of fine structure in the spectra obtained using shaped excitation pulses.
Sensing with undetected photons has enabled new, unconventional approaches to Fourier transform infrared spectroscopy (FT-IR). Leveraging properties of non-degenerate entangled photon pairs, mid-infrared (mid-IR) information can be accessed in the near-infrared (near-IR) spectral domain to perform mid-IR spectroscopy with silicon-based detection schemes. Here, we address practical aspects of vibrational spectroscopy with undetected photons using a quantum FT-IR (QFT-IR) implementation. The system operates in the spectral range from around 3000 cm −1 to 2380 cm −1 (detection at around 12 500 cm −1 ) and possesses only 68 pW of mid-IR probing power for spectroscopic measurements with a power-dependence of the signal-to-noise ratio of 1.5 × 10 5 mW −1/2 . We evaluate the system’s short- and long-term stability and experimentally compare it to a commercial FT-IR instrument using Allan–Werle plots to benchmark our QFT-IR implementation’s overall performance and stability. In addition, comparative qualitative spectroscopic measurements of polymer thin films are performed using the QFT-IR spectrometer and a commercial FT-IR with identical resolution and integration times. Our results show under which conditions QFT-IR can practically be competitive or potentially outperform conventional FT-IR technology.
Electronic structure and dynamics are captured by optical 2D-Fourier-transform (2DFT) spectroscopy, which tracks the phase of the nonlinear signal during two time delays of a multi-pulse excitation sequence. These Fourier-transformed spectra separate and isolate overlapping and competing contributions to the coherent response. We have developed an ultra-stable platform consisting of nested interferometers with active phase control, allowing for exploration of single- and two-quantum coherences. Phase-resolved spectra are retrieved by all-optical determination of experimental phase ambiguities. GaAs quantum wells show suppression of many-body interactions in cross-linear polarized 2DFT spectra and many-body two-quantum coherences. Potassium vapor also shows unexpected two-quantum coherences.
In recent years, nonlinear quantum interferometry has been widely explored for applications like spectroscopy, optical coherence tomography, and imaging [1]. Quantum infrared spectroscopy (QIRS) uses quantum interference of generation processes of frequency-entangled visible-IR photon pairs to perform infrared spectroscopy using visible light sources and silicon-based detectors [2]. This technique utilizes a nonlinear quantum interferometer configuration where the generated IR photons pass through the sample, and the correlated visible photons are detected. The change in the detected visible photon flux with and without the sample helps extract the complex transmittance of the sample in the IR region.