Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Experimental and Theoretical Physics

Conditional preparation of X (2) macroscopic entangled states

Sergey A. Podoshvedov

Published Apr 1, 2006• 3 citations
Publisher

Abstract

Two experimental arrangements consisting of coupled spontaneous parametric down-converters with type-I phase matching pumped simultaneously by a powerful optical field in a coherent state through a balanced beam splitter and linear optical elements are proposed for conditional preparation of macroscopic entangled states in output pumping modes of the studied system. Successful generation of the macroscopic entangled state in the pumping modes is unambiguously heralded by coincident detection of two photons in the generated signal and idler modes of the system. We calculate the amount of entanglement and probabilities of successfully observing the X (2) macroscopic entangled states in the total wavefunction. We show that the proposed schemes can be used to obtain a new type of macroscopic entangled states.

DOI
10.1134/s1063776106040029

Related papers

A simple scheme with coupled down converters with type-I phase matching as resource for conditional preparation of macroscopic entangled states

Sergey A. Podoshvedov, Nguyen Ba An, Jaewan Kim

It is shown that macroscopic entangled states can be generated using an experimental arrangement consisting of coupled spontaneous parametric down-converters with type-I phase matching (SPDCI) pumped simultaneously by optical fields in coherent state and two beam splitters. Two beam splitters in auxiliary generated modes are used to conditionally prepare macroscopic entangled states in output pumping modes of the studied system. Identification of two macroscopic entangled states is produced by use of photon number resolving detection. In contrast to all previous schemes, our scheme does not need Kerr-type nonlinear interaction and is purely based on second-order susceptibility of the crystal which is stronger for the Kerr nonlinearity. We calculate concurrence of the states as a measure of the amount of entanglement stored in the states and present analysis concerning ‘separation’ between components forming studied entangled states.

Journal of Modern Optics•Jun 23, 2006•2 citations

Generation of macroscopic entangled states by means of x(2) nonlinearity without photon number resolving detection

Sergey A. Podoshvedov

We generalize the scheme of conditional preparation of x (2) macroscopic entangled states [S.A. Podoshvedov, JETP 129 (2006)]. The studied system consists of a system of coupled down converters with type-I phase matching pumped simultaneously by powerful optical fields in coherent states with one auxiliary photon in the superposition state of two input modes and a projective measurement system. The projective measurement system involves two Hadamard gates introduced to generated output modes followed by photodetectors. Identification of macroscopic entangled states is produced by registration of one photon. No photon number resolving detection is required for the studied scheme.

Journal of Experimental and Theoretical Physics Letters•Jun 1, 2006•0 citations

Conditional preparation of maximal polarization entanglement

Cezary Śliwa, Konrad Banaszek

A simple experimental setup consisting of a spontaneous parametric down-conversion source and passive linear optics is proposed for conditional preparation of a maximally entangled polarization state of two photons. Successful preparation is unambiguously heralded by coincident detection of four auxiliary photons. The proposed scheme utilizes the down-conversion term corresponding to the generation of three pairs of photons. We analyze imperfect detection of the auxiliary photons and demonstrate that its deleterious effect on the fidelity of the prepared state can be suppressed at the cost of decreasing the efficiency of the scheme.

arXiv:quant-ph/0207117•Physical Review A•Mar 26, 2003•72 citations

Preparation of entangled states of two photons in several spatial modes

Karel Lemr, Jaromı́r Fiurášek

We describe a protocol capable of preparing an arbitrary state of two photons in several spatial modes using pairs of photons generated by spontaneous parametric down conversion, linear optical elements, and single-photon detectors or postselection. The protocol involves unitary and nonunitary transformations realizable by beam splitters and phase shifters. Nonunitary transformations are implemented by attenuation filters. The protocol contains several optimization capabilities with the goal of improving overall probability of its success. We also show how entangled two-photon states required for quantum computing with linear optics can be prepared using a very simple and feasible scheme.

arXiv:0710.0980•Physical Review A•Feb 5, 2008•18 citations

Testing quantum mechanics against macroscopic realism using the output of χ(2) nonlinearity

Sergey A. Podoshvedov, Jaewan Kim

We suggest an all-optical scheme to generate entangled superposition of a single photon with macroscopic entangled states for testing macroscopic realism. The scheme consists of source of single photons, a Mach-Zehnder interferometer in routes of which a system of coupled-down converters with type-I phase matching is inserted, and a beam splitter for the other auxiliary modes of the scheme. We use quantization of the pumping modes, depletion of the coherent states passing through the system, and interference effect in the pumping modes in the process of erasing which-path information of the single-photon on exit from the Mach-Zehnder interferometer. We show the macroscopic fields of the output superposition are distinguishable states. This scheme generates macroscopic entangled state that violates Bell's inequality. Moreover, the detailed analysis concerning change of amplitudes of entangled superposition by means of repeating this process many times is accomplished. We show our scheme works without photon number resolving detection and it is robust to detector inefficiency.

Physical Review A•Sep 15, 2006•15 citations

Nonlinear χ(2) Mach-Zehnder interferometer: Conditional preparation of maximal microscopic entanglement

Sergey A. Podoshvedov, Jaewan Kim

A nonlinear ${\ensuremath{\chi}}^{(2)}$ Mach-Zehnder interferometer is proposed as a simple device for conditional preparation of a two-photon maximally entangled state. Successful generation is unambiguously heralded by detection of a single photon in one of the routes of the nonlinear ${\ensuremath{\chi}}^{(2)}$ Mach-Zehnder interferometer. The mechanism of the conditional preparation is based on interference of the pumping modes. The scheme works without photon-number-resolving detection with a high fidelity.

Physical Review A•Mar 29, 2007•5 citations
Two experimental arrangements consisting of coupled spontaneous parametric down-converters with type-I phase matching pumped simultaneously by a powerful optical field in a coherent state through a balanced beam splitter and linear optical elements are proposed for conditional preparation of macroscopic entangled states in output pumping modes of the studied system. Successful generation of the macroscopic entangled state in the pumping modes is unambiguously heralded by coincident detection of two photons in the generated signal and idler modes of the system. We calculate the amount of entanglement and probabilities of successfully observing the X (2) macroscopic entangled states in the total wavefunction. We show that the proposed schemes can be used to obtain a new type of macroscopic entangled states.
It is shown that macroscopic entangled states can be generated using an experimental arrangement consisting of coupled spontaneous parametric down-converters with type-I phase matching (SPDCI) pumped simultaneously by optical fields in coherent state and two beam splitters. Two beam splitters in auxiliary generated modes are used to conditionally prepare macroscopic entangled states in output pumping modes of the studied system. Identification of two macroscopic entangled states is produced by use of photon number resolving detection. In contrast to all previous schemes, our scheme does not need Kerr-type nonlinear interaction and is purely based on second-order susceptibility of the crystal which is stronger for the Kerr nonlinearity. We calculate concurrence of the states as a measure of the amount of entanglement stored in the states and present analysis concerning ‘separation’ between components forming studied entangled states.
We generalize the scheme of conditional preparation of x (2) macroscopic entangled states [S.A. Podoshvedov, JETP 129 (2006)]. The studied system consists of a system of coupled down converters with type-I phase matching pumped simultaneously by powerful optical fields in coherent states with one auxiliary photon in the superposition state of two input modes and a projective measurement system. The projective measurement system involves two Hadamard gates introduced to generated output modes followed by photodetectors. Identification of macroscopic entangled states is produced by registration of one photon. No photon number resolving detection is required for the studied scheme.
A simple experimental setup consisting of a spontaneous parametric down-conversion source and passive linear optics is proposed for conditional preparation of a maximally entangled polarization state of two photons. Successful preparation is unambiguously heralded by coincident detection of four auxiliary photons. The proposed scheme utilizes the down-conversion term corresponding to the generation of three pairs of photons. We analyze imperfect detection of the auxiliary photons and demonstrate that its deleterious effect on the fidelity of the prepared state can be suppressed at the cost of decreasing the efficiency of the scheme.
We describe a protocol capable of preparing an arbitrary state of two photons in several spatial modes using pairs of photons generated by spontaneous parametric down conversion, linear optical elements, and single-photon detectors or postselection. The protocol involves unitary and nonunitary transformations realizable by beam splitters and phase shifters. Nonunitary transformations are implemented by attenuation filters. The protocol contains several optimization capabilities with the goal of improving overall probability of its success. We also show how entangled two-photon states required for quantum computing with linear optics can be prepared using a very simple and feasible scheme.
We suggest an all-optical scheme to generate entangled superposition of a single photon with macroscopic entangled states for testing macroscopic realism. The scheme consists of source of single photons, a Mach-Zehnder interferometer in routes of which a system of coupled-down converters with type-I phase matching is inserted, and a beam splitter for the other auxiliary modes of the scheme. We use quantization of the pumping modes, depletion of the coherent states passing through the system, and interference effect in the pumping modes in the process of erasing which-path information of the single-photon on exit from the Mach-Zehnder interferometer. We show the macroscopic fields of the output superposition are distinguishable states. This scheme generates macroscopic entangled state that violates Bell's inequality. Moreover, the detailed analysis concerning change of amplitudes of entangled superposition by means of repeating this process many times is accomplished. We show our scheme works without photon number resolving detection and it is robust to detector inefficiency.
A nonlinear ${\ensuremath{\chi}}^{(2)}$ Mach-Zehnder interferometer is proposed as a simple device for conditional preparation of a two-photon maximally entangled state. Successful generation is unambiguously heralded by detection of a single photon in one of the routes of the nonlinear ${\ensuremath{\chi}}^{(2)}$ Mach-Zehnder interferometer. The mechanism of the conditional preparation is based on interference of the pumping modes. The scheme works without photon-number-resolving detection with a high fidelity.