Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Full characterization of quantum optical detectors

Hendrik B. Coldenstrodt-Ronge, A. P. Worsley, Jeff S. Lundeen, Alejandro Feito, K. L. Pregnell, Christine Silberhorn, Peter J. Mosley, Brian J. Smith, Graciana Puentes, Nicholas L. Thomas-Peter, Timothy C. Ralph, Jens Eisert, Martin Bodo Plenio, Ian A. Walmsley

Published Aug 1, 2009• 0 citations
Publisher

Abstract

Full characterization of detectors in the quantum regime is presented. We determine the POVM elements of a photon-number-resolving detector. A method for precise calibration of detector efficiency is demonstrated.
DOI
10.1109/cleopr.2009.5292056

Related papers

High-efficiency and fast photon-number-resolving SNSPD

Lorenzo Stasi, Gaëtan Gras, Riad Berrazouane +1 more

We present a full characterization (efficiency, dark count, recovery time, jit-ter, POVM matrix) of a photon-number-resolving detector based on parallel SNSPD. We construct a model based only on the pixels efficiencies to compute the POVM.

Quantum Information and Measurement (QIM)•Jan 1, 2021•3 citations

Single-shot, full characterization of a single-photon state

Olivier Gazzano, Tim O. Thomay, Elizabeth A. Goldschmidt +3 more

Quantum light parameters (purity, indistinguishability,…) are usually determined using multiple sequential measurements. We demonstrate an efficient single-shot scheme to characterize a quantum dot light using two number-resolving detectors, here simulated by four single-photon detectors.

Conference on Lasers and Electro-Optics•Jan 1, 2016•0 citations

Quantum and Classical Characterization of Single/Few Photon Detectors

M. G. Mingolla, Fabrizio Piacentini, Alessio Avella +10 more

This paper's purpose is to review the results recently obtained in the Quantum Optics labs of the National Institute of Metrological Research (INRIM) in the field of single- and few-photon detectors calibration, from both the classical and quantum viewpoint. In the first part of the paper is presented the calibration of a single-photon detector with absolute methods, while in the second part we focus on photon-number-resolving detectors, discussing both the classical and quantum characterization of such devices.

arXiv:1305.5708•Quantum Matter•Jun 1, 2015•2 citations

Measuring measurement: theory and practice

Alejandro Feito, Jeff S. Lundeen, Hendrik B. Coldenstrodt-Ronge +3 more

Recent efforts have applied quantum tomography techniques to the calibration and characterization of complex quantum detectors using minimal assumptions. In this work, we provide detail and insight concerning the formalism, the experimental and theoretical challenges and the scope of these tomographical tools. Our focus is on the detection of photons with avalanche photodiodes and photon-number resolving detectors and our approach is to fully characterize the quantum operators describing these detectors with a minimal set of well-specified assumptions. The formalism is completely general and can be applied to a wide range of detectors.

arXiv:0906.3440•New Journal of Physics•Sep 28, 2009•106 citations

Simultaneous, full characterization of a single-photon state

Olivier Gazzano, Tim O. Thomay, Elizabeth A. Goldschmidt +3 more

Nonclassical light can be characterized by the state purity and indistinguishability, usually using multiple measurements. We demonstrate an efficient scheme to simultaneously characterize a quantum light source using two number-resolving detectors, here simulated by four single-photon detectors.

Quantum Information and Measurement (QIM)•Jan 1, 2017•3 citations

Macroscopic photon counting beating the Poisson noise limit

Timon Schapeler, Fabian Schlue, Isabell Mischke +4 more

Photon counting is a cornerstone of quantum optics. Here, we demonstrate precisely counting from 0 to over 9000 photons, beating the Poisson noise limit by at least $4.1~\mathrm{dB}$ across this range. We achieve sub-single-photon precision up to 276 photons per pulse. To do so, we multiplex eight intrinsically photon-number-resolving superconducting nanowire single-photon detectors across 128 temporal modes. We use a model-informed characterization of each of the 1024 detection bins, for optimal precision. We perform quantum detector tomography to reconstruct the positive operator valued measures (POVMs) of the complete device, which consists of $1.38\cdot10^8$ matrix elements. At the repetition rate of our experiment of $80~\mathrm{kHz}$, we can precisely count photons corresponding to an optical power of approximately $71~\mathrm{pW}$, bridging the gap from single-photon measurements to high-sensitivity optical power meters. A photon-number-resolving detector of this size, and the tools used to analyze it, will become increasingly important to characterize large quantum states, as well as tasks in precision metrology and optical power standards.

quant-pharXiv:2604.27761•Optica•May 1, 2026•0 citations
This paper's purpose is to review the results recently obtained in the Quantum Optics labs of the National Institute of Metrological Research (INRIM) in the field of single- and few-photon detectors calibration, from both the classical and quantum viewpoint. In the first part of the paper is presented the calibration of a single-photon detector with absolute methods, while in the second part we focus on photon-number-resolving detectors, discussing both the classical and quantum characterization of such devices.
Recent efforts have applied quantum tomography techniques to the calibration and characterization of complex quantum detectors using minimal assumptions. In this work, we provide detail and insight concerning the formalism, the experimental and theoretical challenges and the scope of these tomographical tools. Our focus is on the detection of photons with avalanche photodiodes and photon-number resolving detectors and our approach is to fully characterize the quantum operators describing these detectors with a minimal set of well-specified assumptions. The formalism is completely general and can be applied to a wide range of detectors.
Photon counting is a cornerstone of quantum optics. Here, we demonstrate precisely counting from 0 to over 9000 photons, beating the Poisson noise limit by at least 4.1 dB4.1~\mathrm{dB}4.1 dB across this range. We achieve sub-single-photon precision up to 276 photons per pulse. To do so, we multiplex eight intrinsically photon-number-resolving superconducting nanowire single-photon detectors across 128 temporal modes. We use a model-informed characterization of each of the 1024 detection bins, for optimal precision. We perform quantum detector tomography to reconstruct the positive operator valued measures (POVMs) of the complete device, which consists of 1.38⋅1081.38\cdot10^81.38⋅108 matrix elements. At the repetition rate of our experiment of 80 kHz80~\mathrm{kHz}80 kHz, we can precisely count photons corresponding to an optical power of approximately 71 pW71~\mathrm{pW}71 pW, bridging the gap from single-photon measurements to high-sensitivity optical power meters. A photon-number-resolving detector of this size, and the tools used to analyze it, will become increasingly important to characterize large quantum states, as well as tasks in precision metrology and optical power standards.