Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Frontiers of Physics

Extending the trapping lifetime of single atom in a microscopic far-off-resonance optical dipole trap

Jun He, Baodong Yang, Yongjie Cheng, Tiancai Zhang, Junmin Wang

Published Apr 13, 2011• 15 citations
Publisher

Abstract

In our experiment, a single cesium atom prepared in a large-magnetic-gradient magneto-optical trap (MOT) can be efficiently transferred into a 1064-nm far-off-resonance microscopic optical dipole trap (FORT). The efficient transfer of the single atom between the two traps is used to determine the trapping lifetime and the effective temperature of the single atom in FORT. The typical trapping lifetime has been improved from ∼ 6.9 s to ∼ 130 s by decreasing the background pressure from ∼ 1 × 10 −10 Torr to ∼ 2 × 10 −11 Torr and applying one-shot 10-ms laser cooling phase. We also theoretically investigate the dependence of trapping lifetimes of a single atom in a FORT on trap parameters based on the FORT beam’s intensity noise induced heating. Numerical simulations show that the heating depends on the FORT beam’s waist size and the trap depth. The trapping time can be predicted based on effective temperature measurement of a single atom in the FORT and the intensity noise spectra of the FORT beam. These experimental results are found to be in agreement with the predictions of the heating model.

DOI
10.1007/s11467-011-0179-y

Related papers

Single atoms transferring between a magneto-optical trap and a far-off-resonance optical dipole trap

Jun He, Wang Jing, Baodong Yang +2 more

Based on our work on single cesium atoms trapped in a large-magnetic-gradient vapour-cell magneto-optical trap (MOT), the signal-to-noise ratio (SNR) is remarkably improved. Also a far-off-resonance optical dipole trap (FORT) formed by a strongly-focused 1064 nm single frequency Nd:YVO 4 laser beam is introduced. One cesium atom is prepared in the MOT, and then it can transfer successfully between the MOT and the FORT which is overlapped with the MOT. Utilizing the effective transfer, the lifetime of single atoms trapped in the FORT is measured to be 6.9 ± 0.3 s. Thus we provide a system where the atomic qubit can be coherently manipulated.

Chinese Physics B•Jul 31, 2009•10 citations

Long lifetime of single atom in optical tweezer with laser cooling

Junmin Wang, Jun He, Baodong Yang +2 more

Single cesium atom prepared in a large-magnetic-gradient magneto-optical trap (MOT) has been efficiently loaded into a microscopic far-off-resonance optical trap (FORT, or optical tweezer), and the atom can be transferred back and forth between two traps with high efficiency. The intensity noise spectra of tweezer laser are measured and the heating mechanisms in optical tweezer are analyzed. To prolong the lifetime of single atom trapped in optical tweezer, laser cooling technique is utilized to decrease atom's kinetic energy, and the effective temperature of single atom in tweezer is estimated by the release-and-recapture (R&R) method. Thanks to laser cooling, typical lifetime of ~ 130.6 ± 1.8 s for single atom in tweezer is obtained. These works provides a good starting point for coherent manipulation of single atom.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 30, 2010•2 citations

Towards coherent manipulation of the ground states of single cesium atom confined in a microscopic far-off-resonance optical dipole trap

Wen-Ting Diao, Jun He, Bei Liu +1 more

This work deals with the cooling and trapping of single cesium (Cs) atoms in a large-magnetic-gradient magneto-optical trap (MOT) and the confinement of single Cs atoms in a far-off-resonance optical dipole trap (FORT). The experiment setup is based on two large-numerical-aperture lens assemblies which allow us to strongly focus a 1064-nm TEM00-mode Gaussian laser beam to a 1/e2 radius of ~ 2.3 μm to form a microscopic FORT for isolating single atom with environment and to efficiently collect the laser-induced-fluorescence photons emitted by single atoms for detecting and recognizing single atom’s internal state. We have tried both of “bottom-up” and “top-down” loading schemes to confine single atoms in the microscopic FORT. In the “bottom-up” scheme, we have successfully prepared single Cs atoms in the MOT and transferred it into FORT with a probability of almost 100%. In the “top-down” scheme, we have achieved ~ 74% of single atom loading probability in the FORT using light-assisted collisions induced by blue detuning laser and with prepared many Cs atoms in the MOT. The relaxation time in hyperfine level of ground state of trapped single Cs atom is measured to be ~5.4 s. To coherently manipulate atomic quantum bits (qubit) encoded in the clock states (mF = 0 states in Fg = 3 and 4 hyperfine levels) of single Cs atom via the two-photon simulated Raman adiabatic passage (STIRAP), we have prepared two phase-locked laser beams with a frequency difference of ~ 9.192 GHz by optically injecting an 852-nm master laser to lock the +1-order sideband of a 9-GHz current-modulated slave diode laser. The two phase-locked laser beams are used to drive STIRAP process in the Λ-type three-level system consists of Cs |6S1/2 Fg = 4, mF = 0> and |6S1/2 Fg = 3, mF = 0< long-lived clock states and Cs |6S1/2 Fe = 4, mF = +1 > excited state with the single-photon detuning of ~ -20 GHz. Rabi flopping experiments are in progress.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Nov 29, 2012•0 citations

Efficient extension of the trapping lifetime of single atoms in an optical tweezer by laser cooling

Jun He, Baodong Yang, Tiancai Zhang +1 more

Optical tweezers have become powerful tools for the confinement and manipulation of neutral atoms, molecules, mesoscopic biological molecules and living cells. In our experiment, a single caesium atom was prepared in a large-magnetic-gradient magneto-optical trap (MOT). It was then efficiently transferred back and forth between the MOT and a 1064 nm microscopic optical tweezer. The atomic transfer between the MOT and the tweezer can be employed to measure the trapping lifetime and the energy distribution of the single atom in the tweezer. In order to extend the trapping lifetime, laser cooling is used to decrease the atom's kinetic energy. The trapping lifetime was extended from ∼75 to ∼130 s by applying a 10 ms laser cooling phase just after the single atom is transferred into the tweezer.

Physica Scripta•Jul 19, 2011•9 citations

852-nm triggered single-photon source based on trapping and manipulation of a single cesium atom confined in a microscopic optical dipole trap

Liu Bei, Jin Gang, Jun He +1 more

Single-atom-based single-photon source has several advantages, such as narrow bandwidth, wavelength matching with the absorption line of the same atomic ensemble, and insensitivity to the environment disturbing, and it is very important not only for basic researches in quantum optic field but also for applications in quantum information processing. In this paper, we report the generation of a 10-MHz-repetition-rate triggered single-photon source at 852 nm based on a trapped single cesium atom in a far-off-resonance microscopic optical dipole trap (FORT). To generate an optical dipole trap, a far-red-detuned 1064 nm laser beam is tightly focused by using a high numerical aperture lens, a typical trap depth is 2 mK and trap waist is 2.3 m. To obtain a maximum probability of pulsed excitation, the frequency of the pulsed laser should be resonant with the atomic energy levels and the trapped single atom must be excited with a -pulse. However, the interaction between the FORT laser and the atoms causes AC Stark shifts of the atomic energy levels. Thus, in order to demonstrate the resonant pulsed excitation, it is important to calculate and measure the shift of 6S1/2|Fg=4,mF=+4-6P3/2|Fe=5,mF=+5 cyclical transition in the FORT. For a two-level system, the probability of pulsed excitation can be described by Rabi oscillations with a characteristic Rabi frequency . With an optimized time sequence, we experimentally demonstrate the Rabi oscillation between the ground state and the excited state, and the peak power of -pulse laser is about 1.25 mW. We also measure the temporal envelope of single photons after a -pulse excitation. A gated pulsed excitation and cooling technique are used to reduce the possibility that atoms are heated by -pulse laser. The typical trapping lifetime of single cesium atom is extended from~108 ups to~2536 ms. The corresponding number of excitations is improved from 108 to 360000. The second-order intensity correlations of the emitted single-photon are characterized by implementing Hanbury Brown-Twiss setup. The statistics shows a strong anti-bunching with a value of 0.09 for the second-order correlation at zero delay. In the future, we will perform a Hong-Ou-Mandel two-photon interference experiment to analyze the indistinguishability of the single photons. We will also trap single atoms in a magic-wavelength optical dipole trap where the ground and the excited states have the same shift.

Acta Physica Sinica•Jan 1, 2016•0 citations

Increasing the trapping lifetime of lithium-7 atoms in optical dipole trap

Sergey A. Saakyan, Vladimir A. Sautenkov, N. V. Morozov +2 more

Abstract We have developed far-off resonance single beam dipole trap for optically cooled lithium-7 atoms. In the present paper we discuss some preliminary results. In order to improve performance of the trap we optimized the trapping time and increased the atoms number. The lifetime was increased by improving the vacuum from ≈ 3 × 10−10 Torr to ≈ 10−11 Torr and preparing all the atoms in the selected atomic state (the lower ground state level). After vacuum improvement the single particle losses in the magneto-optical trap was reduced by 100 times and as the result the lifetime in the dipole trap reached 25 s.

Journal of Physics Conference Series•Feb 1, 2021•1 citation
In our experiment, a single cesium atom prepared in a large-magnetic-gradient magneto-optical trap (MOT) can be efficiently transferred into a 1064-nm far-off-resonance microscopic optical dipole trap (FORT). The efficient transfer of the single atom between the two traps is used to determine the trapping lifetime and the effective temperature of the single atom in FORT. The typical trapping lifetime has been improved from ∼ 6.9 s to ∼ 130 s by decreasing the background pressure from ∼ 1 × 10 −10 Torr to ∼ 2 × 10 −11 Torr and applying one-shot 10-ms laser cooling phase. We also theoretically investigate the dependence of trapping lifetimes of a single atom in a FORT on trap parameters based on the FORT beam’s intensity noise induced heating. Numerical simulations show that the heating depends on the FORT beam’s waist size and the trap depth. The trapping time can be predicted based on effective temperature measurement of a single atom in the FORT and the intensity noise spectra of the FORT beam. These experimental results are found to be in agreement with the predictions of the heating model.
Based on our work on single cesium atoms trapped in a large-magnetic-gradient vapour-cell magneto-optical trap (MOT), the signal-to-noise ratio (SNR) is remarkably improved. Also a far-off-resonance optical dipole trap (FORT) formed by a strongly-focused 1064 nm single frequency Nd:YVO 4 laser beam is introduced. One cesium atom is prepared in the MOT, and then it can transfer successfully between the MOT and the FORT which is overlapped with the MOT. Utilizing the effective transfer, the lifetime of single atoms trapped in the FORT is measured to be 6.9 ± 0.3 s. Thus we provide a system where the atomic qubit can be coherently manipulated.
Single cesium atom prepared in a large-magnetic-gradient magneto-optical trap (MOT) has been efficiently loaded into a microscopic far-off-resonance optical trap (FORT, or optical tweezer), and the atom can be transferred back and forth between two traps with high efficiency. The intensity noise spectra of tweezer laser are measured and the heating mechanisms in optical tweezer are analyzed. To prolong the lifetime of single atom trapped in optical tweezer, laser cooling technique is utilized to decrease atom's kinetic energy, and the effective temperature of single atom in tweezer is estimated by the release-and-recapture (R&R) method. Thanks to laser cooling, typical lifetime of ~ 130.6 ± 1.8 s for single atom in tweezer is obtained. These works provides a good starting point for coherent manipulation of single atom.
This work deals with the cooling and trapping of single cesium (Cs) atoms in a large-magnetic-gradient magneto-optical trap (MOT) and the confinement of single Cs atoms in a far-off-resonance optical dipole trap (FORT). The experiment setup is based on two large-numerical-aperture lens assemblies which allow us to strongly focus a 1064-nm TEM00-mode Gaussian laser beam to a 1/e2 radius of ~ 2.3 μm to form a microscopic FORT for isolating single atom with environment and to efficiently collect the laser-induced-fluorescence photons emitted by single atoms for detecting and recognizing single atom’s internal state. We have tried both of “bottom-up” and “top-down” loading schemes to confine single atoms in the microscopic FORT. In the “bottom-up” scheme, we have successfully prepared single Cs atoms in the MOT and transferred it into FORT with a probability of almost 100%. In the “top-down” scheme, we have achieved ~ 74% of single atom loading probability in the FORT using light-assisted collisions induced by blue detuning laser and with prepared many Cs atoms in the MOT. The relaxation time in hyperfine level of ground state of trapped single Cs atom is measured to be ~5.4 s. To coherently manipulate atomic quantum bits (qubit) encoded in the clock states (mF = 0 states in Fg = 3 and 4 hyperfine levels) of single Cs atom via the two-photon simulated Raman adiabatic passage (STIRAP), we have prepared two phase-locked laser beams with a frequency difference of ~ 9.192 GHz by optically injecting an 852-nm master laser to lock the +1-order sideband of a 9-GHz current-modulated slave diode laser. The two phase-locked laser beams are used to drive STIRAP process in the Λ-type three-level system consists of Cs |6S1/2 Fg = 4, mF = 0> and |6S1/2 Fg = 3, mF = 0< long-lived clock states and Cs |6S1/2 Fe = 4, mF = +1 > excited state with the single-photon detuning of ~ -20 GHz. Rabi flopping experiments are in progress.
Optical tweezers have become powerful tools for the confinement and manipulation of neutral atoms, molecules, mesoscopic biological molecules and living cells. In our experiment, a single caesium atom was prepared in a large-magnetic-gradient magneto-optical trap (MOT). It was then efficiently transferred back and forth between the MOT and a 1064 nm microscopic optical tweezer. The atomic transfer between the MOT and the tweezer can be employed to measure the trapping lifetime and the energy distribution of the single atom in the tweezer. In order to extend the trapping lifetime, laser cooling is used to decrease the atom's kinetic energy. The trapping lifetime was extended from ∼75 to ∼130 s by applying a 10 ms laser cooling phase just after the single atom is transferred into the tweezer.
Single-atom-based single-photon source has several advantages, such as narrow bandwidth, wavelength matching with the absorption line of the same atomic ensemble, and insensitivity to the environment disturbing, and it is very important not only for basic researches in quantum optic field but also for applications in quantum information processing. In this paper, we report the generation of a 10-MHz-repetition-rate triggered single-photon source at 852 nm based on a trapped single cesium atom in a far-off-resonance microscopic optical dipole trap (FORT). To generate an optical dipole trap, a far-red-detuned 1064 nm laser beam is tightly focused by using a high numerical aperture lens, a typical trap depth is 2 mK and trap waist is 2.3 m. To obtain a maximum probability of pulsed excitation, the frequency of the pulsed laser should be resonant with the atomic energy levels and the trapped single atom must be excited with a -pulse. However, the interaction between the FORT laser and the atoms causes AC Stark shifts of the atomic energy levels. Thus, in order to demonstrate the resonant pulsed excitation, it is important to calculate and measure the shift of 6S1/2|Fg=4,mF=+4-6P3/2|Fe=5,mF=+5 cyclical transition in the FORT. For a two-level system, the probability of pulsed excitation can be described by Rabi oscillations with a characteristic Rabi frequency . With an optimized time sequence, we experimentally demonstrate the Rabi oscillation between the ground state and the excited state, and the peak power of -pulse laser is about 1.25 mW. We also measure the temporal envelope of single photons after a -pulse excitation. A gated pulsed excitation and cooling technique are used to reduce the possibility that atoms are heated by -pulse laser. The typical trapping lifetime of single cesium atom is extended from~108 ups to~2536 ms. The corresponding number of excitations is improved from 108 to 360000. The second-order intensity correlations of the emitted single-photon are characterized by implementing Hanbury Brown-Twiss setup. The statistics shows a strong anti-bunching with a value of 0.09 for the second-order correlation at zero delay. In the future, we will perform a Hong-Ou-Mandel two-photon interference experiment to analyze the indistinguishability of the single photons. We will also trap single atoms in a magic-wavelength optical dipole trap where the ground and the excited states have the same shift.
Abstract We have developed far-off resonance single beam dipole trap for optically cooled lithium-7 atoms. In the present paper we discuss some preliminary results. In order to improve performance of the trap we optimized the trapping time and increased the atoms number. The lifetime was increased by improving the vacuum from ≈ 3 × 10−10 Torr to ≈ 10−11 Torr and preparing all the atoms in the selected atomic state (the lower ground state level). After vacuum improvement the single particle losses in the magneto-optical trap was reduced by 100 times and as the result the lifetime in the dipole trap reached 25 s.