The interaction of an intense microwave electric field with Cr3+ ions in ruby is investigated. The authors report solutions for the electric and magnetic polarisation vectors oscillating at the second-harmonic frequency of the driving field and a comparison with experimental data.
Two-photon transitions in a nearly resonant three-level spin system are experimentally investigated at microwave frequencies by detecting the second harmonic (SH) wave emitted by a resonant paramagnetic spin sample. The dependence of the SH intensity and lineshape on the detuning of the intermediate level from the resonance is measured in a dilute ruby sample (Cr 3+ :Al 2 O 3 ). It is shown that the SH output is the coherent superposition of two different contributions which come, respectively, from processes which involve all three levels and from Raman-like processes to which the intermediate level does not take part. The dependence on the intensity and polarisation of the input radiation is measured for each one of the two kinds of processes and interference effects between them are detected.
We present an atom-based approach for determining microwave electric and magnetic fields by using a single rubidium vapor cell in a microwave waveguide. For a 87Rb cascade three-level system employed in our experiment, a weak probe laser driving the lower transition, 5S1/2→5P3/2, is first used to measure the microwave magnetic field based on the atomic Rabi resonance. When a counter-propagating strong coupling laser is subsequently turned on to drive the Rydberg transition, 5P3/2→67D5/2, the same probe laser is then used as a Rydberg electromagnetically induced transparency (EIT) probe to measure the microwave electric field by investigating the resonant microwave dressed Autler-Townes splitting (ATS). By tuning the hyperfine transition frequency of the ground state using an experimentally feasible static magnetic field, we first achieved a measurement of the microwave electric and magnetic field strength at the same microwave frequency of 6.916 GHz. Based on the ideal relationship between the electric and magnetic field components, we obtained the equivalent microwave magnetic fields by fitting the inversion to the measured microwave electric fields, which demonstrated that the results were in agreement with the experimental measurement of the microwave magnetic fields in the same microwave power range. This study provides new experimental evidence for quantum-based microwave measurements of electric and magnetic fields by a single sensor in the same system.