We derive an expression for Δtmin, the mimimum pulse duration (’’valve open time’’) required if a pulsed nozzle is to produce a supersonic beam comparably ’’cold’’ to that obtained from a continuous source.(AIP)
We describe a generally applicable method for the experimental determination of stationary flow conditions in pulsed supersonic beams, utilizing time-resolved electron induced fluorescence measurements of high pressure jet expansions of helium. The detection of ultraviolet photons from electronically excited helium emitted very close to the nozzle exit images the valve opening behavior-with the decided advantage that a photon signal is not affected by beam-skimmer and beam-residual gas interactions; it thus allows to conclusively determine those operation parameters of a pulsed valve that yield complete opening. The studies reveal that a "flat-top" signal, indicating constant density and commonly considered as experimental criterion for continuous flow, is insufficient. Moreover, translational temperature and mean terminal flow velocity turn out to be significantly more sensitive in testing for the equivalent behavior of a continuous nozzle source. Based on the widely distributed Even-Lavie valve we demonstrate that, in principle, it is possible to achieve quasi-continuous flow conditions even with fast-acting valves; however, the two prerequisites are a minimum pulse duration that is much longer than standard practice and previous estimates, and a suitable tagging of the appropriate beam segment.
Recent merged neutral beam experiments have introduced the possibility of measuring reactive collisions in the cold regime down to 10 mK. The lowest temperature attained in these experiments cannot be explained using the standard formalism developed for crossed molecular beam scattering. These low temperatures become accessible because pulsed supersonic beams develop a correlation in velocity-position space during free propagation such that the local velocity standard deviation decreases. This effect is responsible for a reduction in the attainable collision energy by more than 2 orders of magnitude along with an order of magnitude improvement in the resolution. We show that supersonic nozzles with short pulsed opening durations compared to the time-of-flight, such as the Even-Lavie valve, have a clear advantage in achieving low collision energies with improved resolution. We discuss possible improvements in the energy resolution by varying the detection time duration.