EPJ Techniques and Instrumentation

Optimal beam sources for Stark decelerators in collision experiments: a tutorial review

Sjoerd N. Vogels, Gao Zhi, Sebastiaan Y. T. van de Meerakker

Published Aug 5, 2015• 20 citations
Publisher

Abstract

With the Stark deceleration technique, packets of molecules with a tunable velocity, a narrow velocity spread, and a high state purity can be produced. These tamed molecular beams find applications in high resolution spectroscopy, cold molecule trapping, and controlled scattering experiments. The quality and purity of the packets of molecules emerging from the decelerator critically depend on the specifications of the decelerator, but also on the characteristics of the molecular beam pulse with which the decelerator is loaded. We consider three frequently used molecular beam sources, and discuss their suitability for molecular beam deceleration experiments, in particular with the application in crossed beam scattering in mind. The performance of two valves in particular, the Nijmegen Pulsed Valve and the Jordan Valve, is illustrated by decelerating ND 3 molecules in a 2.6 meter-long Stark decelerator. We describe a protocol to characterize the valve, and to optimally load the pulse of molecules into the decelerator. We characterize the valves regarding opening time duration, optimal valve-to-skimmer distance, mean velocity, velocity spread, state purity, and relative intensity.

DOI
10.1140/epjti/s40485-015-0021-y

Related papers

Optimizing the density of Stark decelerated radicals at low final velocities: a tutorial review

Dominik A. Haas, Sebastian Scherb, Dongdong Zhang +1 more

The Stark deceleration technique can produce molecular beams with very low velocities. In order to maximize the density of decelerated molecules, experimental parameters such as the velocity, the velocity spread and the spatial spread of the initial molecular beam as well as the operation characteristics of the decelerator have to be chosen appropriately. In this tutorial review, we describe procedures for the optimization of the density of Stark decelerated radicals for low-velocity applications which are of interest in, e.g., molecule trapping and cold-collision studies.

EPJ Techniques and Instrumentation•Sep 25, 2017•6 citations

Unraveling Cold Molecular Collisions: Stark Decelerators in Crossed‐Beam Experiments

Jolijn Onvlee, Sjoerd N. Vogels, Sebastiaan Y. T. van de Meerakker

In the last two decades, enormous progress has been made in the manipulation of molecular beams. In particular, molecular decelerators have been developed with which advanced control over neutral molecules in a beam can be achieved. By using arrays of inhomogeneous and time-varying electric (or magnetic) fields, bunches of molecules can be produced with a tunable velocity, narrow velocity spreads, and almost perfect quantum-state purity. These monochromatic or "tamed" molecular beams are ideally suited to be used in crossed-molecular-beam scattering experiments. Here, we review the first generation of these "cold and controlled" scattering experiments that have been conducted in the last decade and discuss the prospects for this emerging field of research in the years to come.

ChemPhysChem•Sep 14, 2016•14 citations

Method for traveling-wave deceleration of buffer-gas beams of CH

Maya Fabrikant, Tian Li, Noah J. Fitch +3 more

Cryogenic buffer-gas beams are a promising method for producing bright sources of cold molecular radicals for cold-collision and chemical-reaction experiments. In order to use these beams in studies of reactions with controlled collision energies or in trapping experiments, one needs a method of controlling the forward velocity of the beam. A Stark decelerator can be an effective tool for controlling the mean speed of molecules produced by supersonic jets, but efficient deceleration of buffer-gas beams presents new challenges due to longer pulse lengths. Traveling-wave decelerators are uniquely suited to meet these challenges because of their ability to confine molecules in three dimensions during deceleration and their versatility afforded by the analog control of the electrodes. We have created ground-state $\mathrm{CH}(X{\phantom{\rule{0.16em}{0ex}}}^{2}\ensuremath{\Pi})$ radicals in a cryogenic buffer-gas cell with the potential to produce a cold molecular beam of ${10}^{11}$ molecules/pulse. We present a general protocol for Stark deceleration of beams with a large position and velocity spread for use with a traveling-wave decelerator. Our method involves confining molecules transversely with a hexapole for an optimized distance before deceleration. This rotates the phase-space distribution of the molecular packet so that the packet is matched to the time-varying phase-space acceptance of the decelerator. We demonstrate with simulations and an analytic one-dimensional model that this method can decelerate a significant fraction of the molecules in successive wells of a traveling-wave decelerator to produce energy-tuned beams for cold and controlled-molecule experiments.

arXiv:1312.0901•Physical Review A•Sep 17, 2014•18 citations

High-energy-resolution molecular beams for cold collision studies

Lambert Paul Parazzoli, Noah J. Fitch, Dan Lobser +1 more

Stark deceleration allows for precise control over the velocity of a pulsed molecular beam and, by the nature of its limited phase-space acceptance, reduces the energy width of the decelerated packet. We describe an alternate method of operating a Stark decelerator that further reduces the energy spread over the standard method of operation. In this alternate mode of operation, we aggressively decelerate the molecular packet using a high phase angle. This technique brings the molecular packet to the desired velocity before it reaches the end of the decelerator; the remaining stages are then used to longitudinally and transversely guide the packet to the detection/interaction region. The result of the initial aggressive slowing is a reduction in the phase-space acceptance of the decelerator and thus a narrowing of the velocity spread of the molecular packet. In addition to the narrower energy spread, this method also results in a velocity spread that is nearly independent of the final velocity. Using the alternate deceleration technique, the energy resolution of molecular collision measurements can be improved considerably.

arXiv:0902.1499•New Journal of Physics•May 14, 2009•19 citations

STARK DECELERATION AND TRAPPING OF OH RADICALS

Sebastiaan Y. T. van de Meerakker, Nicolas Vanhaecke, Gerard Meijer

The motion of polar molecules can be controlled by time-varying inhomogeneous electric fields. In a Stark decelerator, this is exploited to accelerate, transport, or decelerate a fraction of a molecular beam. When combined with a trap, the decelerator provides a means to store the molecules for times up to seconds. Here, we review our efforts to produce cold molecules via this technique. In particular, we present a new generation Stark decelerator and electrostatic trap that selects a significant part of a molecular beam pulse that can be loaded into the trap. Deceleration and trapping experiments using a beam of OH radicals are discussed.

Annual Review of Physical Chemistry•Dec 1, 2005•90 citations

Deceleration of a Supersonic Beam of SrF Molecules

Sreekanth Chirayath Mathavan

The work depicted in this thesis demonstrate the successful operation of a 4 meter long traveling-wave Stark decelerator. This is a novel tool for deceleration of heavy diatomic molecules to arbitrarily slow beams with a very small velocity spread which can serve as ideal starting point for precision tests of fundamental physics. The first part of the thesis discusses the characterization of a new Supersonic beam source for creation of SrF molecules which serves as an ideal candidate for precision test of nuclear spin dependent parity violation. The later part of the thesis discusses the the results of deceleration of a SrF molecules in the N = 1 rotation state of the SrF(v = 0) electronic ground state from a supersonic beam with an initial velocity of 340 m/s to 265 m/s using a deceleration potential with 3.25 k V voltage amplitude using a the 4 m long traveling-wave decelerator built in our research lab. Increasing the voltage amplitude of the potential to 4.8 kV, we were able to decelerate molecules from 340 m/s to 250 m/s which corresponds to a deceleration strength of 6.6 km /s2. By cooling the valve by flushing cold nitrogen gas through the valve enclosure we were able to decrease the initial velocity of the supersonic beam. With the valve cooled to ~190 K, we demonstrated deceleration of SrF molecules from 290 m/s to 120 m/s which corresponds to the removal of almost 85% of the initial kinetic energy. The thesis described the operation of the decelerator and end with an outlook for precision tests using this novel tool.

•Jun 13, 2023•0 citations
With the Stark deceleration technique, packets of molecules with a tunable velocity, a narrow velocity spread, and a high state purity can be produced. These tamed molecular beams find applications in high resolution spectroscopy, cold molecule trapping, and controlled scattering experiments. The quality and purity of the packets of molecules emerging from the decelerator critically depend on the specifications of the decelerator, but also on the characteristics of the molecular beam pulse with which the decelerator is loaded. We consider three frequently used molecular beam sources, and discuss their suitability for molecular beam deceleration experiments, in particular with the application in crossed beam scattering in mind. The performance of two valves in particular, the Nijmegen Pulsed Valve and the Jordan Valve, is illustrated by decelerating ND 3 molecules in a 2.6 meter-long Stark decelerator. We describe a protocol to characterize the valve, and to optimally load the pulse of molecules into the decelerator. We characterize the valves regarding opening time duration, optimal valve-to-skimmer distance, mean velocity, velocity spread, state purity, and relative intensity.
The Stark deceleration technique can produce molecular beams with very low velocities. In order to maximize the density of decelerated molecules, experimental parameters such as the velocity, the velocity spread and the spatial spread of the initial molecular beam as well as the operation characteristics of the decelerator have to be chosen appropriately. In this tutorial review, we describe procedures for the optimization of the density of Stark decelerated radicals for low-velocity applications which are of interest in, e.g., molecule trapping and cold-collision studies.
In the last two decades, enormous progress has been made in the manipulation of molecular beams. In particular, molecular decelerators have been developed with which advanced control over neutral molecules in a beam can be achieved. By using arrays of inhomogeneous and time-varying electric (or magnetic) fields, bunches of molecules can be produced with a tunable velocity, narrow velocity spreads, and almost perfect quantum-state purity. These monochromatic or "tamed" molecular beams are ideally suited to be used in crossed-molecular-beam scattering experiments. Here, we review the first generation of these "cold and controlled" scattering experiments that have been conducted in the last decade and discuss the prospects for this emerging field of research in the years to come.
Cryogenic buffer-gas beams are a promising method for producing bright sources of cold molecular radicals for cold-collision and chemical-reaction experiments. In order to use these beams in studies of reactions with controlled collision energies or in trapping experiments, one needs a method of controlling the forward velocity of the beam. A Stark decelerator can be an effective tool for controlling the mean speed of molecules produced by supersonic jets, but efficient deceleration of buffer-gas beams presents new challenges due to longer pulse lengths. Traveling-wave decelerators are uniquely suited to meet these challenges because of their ability to confine molecules in three dimensions during deceleration and their versatility afforded by the analog control of the electrodes. We have created ground-state $\mathrm{CH}(X{\phantom{\rule{0.16em}{0ex}}}^{2}\ensuremath{\Pi})$ radicals in a cryogenic buffer-gas cell with the potential to produce a cold molecular beam of 1011{10}^{11}1011 molecules/pulse. We present a general protocol for Stark deceleration of beams with a large position and velocity spread for use with a traveling-wave decelerator. Our method involves confining molecules transversely with a hexapole for an optimized distance before deceleration. This rotates the phase-space distribution of the molecular packet so that the packet is matched to the time-varying phase-space acceptance of the decelerator. We demonstrate with simulations and an analytic one-dimensional model that this method can decelerate a significant fraction of the molecules in successive wells of a traveling-wave decelerator to produce energy-tuned beams for cold and controlled-molecule experiments.
Stark deceleration allows for precise control over the velocity of a pulsed molecular beam and, by the nature of its limited phase-space acceptance, reduces the energy width of the decelerated packet. We describe an alternate method of operating a Stark decelerator that further reduces the energy spread over the standard method of operation. In this alternate mode of operation, we aggressively decelerate the molecular packet using a high phase angle. This technique brings the molecular packet to the desired velocity before it reaches the end of the decelerator; the remaining stages are then used to longitudinally and transversely guide the packet to the detection/interaction region. The result of the initial aggressive slowing is a reduction in the phase-space acceptance of the decelerator and thus a narrowing of the velocity spread of the molecular packet. In addition to the narrower energy spread, this method also results in a velocity spread that is nearly independent of the final velocity. Using the alternate deceleration technique, the energy resolution of molecular collision measurements can be improved considerably.
The motion of polar molecules can be controlled by time-varying inhomogeneous electric fields. In a Stark decelerator, this is exploited to accelerate, transport, or decelerate a fraction of a molecular beam. When combined with a trap, the decelerator provides a means to store the molecules for times up to seconds. Here, we review our efforts to produce cold molecules via this technique. In particular, we present a new generation Stark decelerator and electrostatic trap that selects a significant part of a molecular beam pulse that can be loaded into the trap. Deceleration and trapping experiments using a beam of OH radicals are discussed.
The work depicted in this thesis demonstrate the successful operation of a 4 meter long traveling-wave Stark decelerator. This is a novel tool for deceleration of heavy diatomic molecules to arbitrarily slow beams with a very small velocity spread which can serve as ideal starting point for precision tests of fundamental physics. The first part of the thesis discusses the characterization of a new Supersonic beam source for creation of SrF molecules which serves as an ideal candidate for precision test of nuclear spin dependent parity violation. The later part of the thesis discusses the the results of deceleration of a SrF molecules in the N = 1 rotation state of the SrF(v = 0) electronic ground state from a supersonic beam with an initial velocity of 340 m/s to 265 m/s using a deceleration potential with 3.25 k V voltage amplitude using a the 4 m long traveling-wave decelerator built in our research lab. Increasing the voltage amplitude of the potential to 4.8 kV, we were able to decelerate molecules from 340 m/s to 250 m/s which corresponds to a deceleration strength of 6.6 km /s2. By cooling the valve by flushing cold nitrogen gas through the valve enclosure we were able to decrease the initial velocity of the supersonic beam. With the valve cooled to ~190 K, we demonstrated deceleration of SrF molecules from 290 m/s to 120 m/s which corresponds to the removal of almost 85% of the initial kinetic energy. The thesis described the operation of the decelerator and end with an outlook for precision tests using this novel tool.