Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Bulletin of the American Physical Society

Parametric amplification with the Cavity Josephson Amplifier

Etienne Boaknin, Rajamani Vijay, Michael Metcalfe, Vladimir Manucharyan, Irfan A. Siddiqi, Michel Devoret

Published Mar 16, 2006• 0 citations
OpenAlex

Related papers

Nearly noiseless amplification of microwave signals with a Josephson parametric amplifier

Manuel A. Castellanos-Beltran

Bulletin of the American Physical Society•Mar 17, 2009•0 citations

Broadband squeezed microwaves and amplification with a Josephson travelling-wave parametric amplifier

Jack Y. Qiu, Arne L. Grimsmo, Kaidong Peng +16 more

arXiv:2201.11261•Nature Physics•Feb 9, 2023•80 citations

Parametric amplification in a Josephson junction array Fabry-Pérot cavity

Javier Navarro Montilla, Nikita S. Klimovich, A. Barbier +2 more

Abstract Superconducting Parametric Amplifiers (SPAs) with near-quantum-limited added noise are crucial for weak signal detection applications such as astronomical receivers, quantum computation, and fundamental physics experiments. Commercially available SPAs include Josephson Parametric Amplifiers (JPAs), which offer high gain but narrow bandwidth performance; and Josephson-junction Travelling Wave Parametric Amplifiers (JTWPAs), which provide broader bandwidth at the cost of a complicated fabrication procedure, lower fabrication yield, and larger footprint area. In this paper, we investigate the parametric amplification of microwave signals in a Josephson array embedded in a low-Q Fabry-Pérot cavity. We fabricated a 500-junction array device and measured >15 dB phase-preserving gain over a ∼350 MHz bandwidth, while offering almost two orders of magnitude improvement in compression point (P 1dB = −106.2 dBm) compared to standard JPAs. Furthermore, using a novel measurement technique, we configured our device to operate in the phase-sensitive mode, measuring a phase-sensitive extinction ratio (PSER) of 42.3 ± 2.81 dB, in line with state-of-the-art values for JPAs. These promising performances, combined with the ease of fabrication and improved yield compared with JTWPAs, underscore the potential of these devices for applications in advanced detection schemes.

Physica Scripta•Sep 1, 2025•1 citation

Parametric amplification using a point contact Josephson junction

Panu Juhani Somervuo

NASA STI/Recon Technical Report N•Jan 1, 1976•0 citations

Parametric Amplification in Discrete Josephson Transmission Line

Hamid Reza Mohebbi, A. Hamed Majedi

Bulletin of the American Physical Society•Mar 24, 2011•0 citations

Four photon parametric amplification

P. T. Parrish, M. J. Feldman, Hiroshi Ohta +1 more

An analysis is presented describing four-photon parametric amplification in an unbiased Josephson junction. Central to the theory is the model of the Josephson effect as a nonlinear inductance. Linear, small signal analysis is applied to the « two fluid » model of the Josephson junction. The gain, gain-bandwidth product, high frequency limit and effective noise temperature is calculated for a cavity reflection amplifier. The analysis is extended to multiple (series-connected) junctions and sub-harmonic pumping.

Revue de Physique Appliquée•Jan 1, 1974•13 citations
Abstract Superconducting Parametric Amplifiers (SPAs) with near-quantum-limited added noise are crucial for weak signal detection applications such as astronomical receivers, quantum computation, and fundamental physics experiments. Commercially available SPAs include Josephson Parametric Amplifiers (JPAs), which offer high gain but narrow bandwidth performance; and Josephson-junction Travelling Wave Parametric Amplifiers (JTWPAs), which provide broader bandwidth at the cost of a complicated fabrication procedure, lower fabrication yield, and larger footprint area. In this paper, we investigate the parametric amplification of microwave signals in a Josephson array embedded in a low-Q Fabry-Pérot cavity. We fabricated a 500-junction array device and measured >15 dB phase-preserving gain over a ∼350 MHz bandwidth, while offering almost two orders of magnitude improvement in compression point (P 1dB = −106.2 dBm) compared to standard JPAs. Furthermore, using a novel measurement technique, we configured our device to operate in the phase-sensitive mode, measuring a phase-sensitive extinction ratio (PSER) of 42.3 ± 2.81 dB, in line with state-of-the-art values for JPAs. These promising performances, combined with the ease of fabrication and improved yield compared with JTWPAs, underscore the potential of these devices for applications in advanced detection schemes.
An analysis is presented describing four-photon parametric amplification in an unbiased Josephson junction. Central to the theory is the model of the Josephson effect as a nonlinear inductance. Linear, small signal analysis is applied to the « two fluid » model of the Josephson junction. The gain, gain-bandwidth product, high frequency limit and effective noise temperature is calculated for a cavity reflection amplifier. The analysis is extended to multiple (series-connected) junctions and sub-harmonic pumping.