Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

InTech eBooks

Shape of the Coherent Population Trapping Resonances Registered in Fluorescence

S. Gateva, G. Todorov

Published Mar 23, 2012• 0 citations
Publisher

Abstract

There has been permanent interest in investigations of new magnetic sensors and their various applications (Edelstein, 2007). Last years there is a rapid progress in development of magneto-optical sensors because of their sensitivity and potential for miniaturization. Magnetometers, based on magneto-optical sensors have high sensitivity comparable to, or even surpassing this of the SQUIDs (Superconducting Quantum Interference Devices) (Kominis et al., 2003; Dang et al., 2010; Savukov, 2010; Knappe, 2010). Microfabrication of components using the techniques of Micro-Electro-Mechanical Systems (MEMS) developed for atomic clocks (Knappe, 2004) gives the opportunity for building small, low consuming, low cost and non-cryogenic (as SQUIDs) sensors (Griffith et al., 2010). Coherent optical effects can be applied for magnetic field detection and offer perspectives for development of high-precision optical magnetometers (Cox et al., 2011; Kitching et al., 2011). These magnetometers are appropriate for geomagnetic, space, nuclear and biological magnetic field measurements (cardio and brain magnetic field imaging), environmental monitoring, magnetic microscopy, investigations of fundamental physics, etc. Coherent magneto-optical resonances have many applications not only in magnetometry, but in high-resolution spectroscopy, lasing without inversion, laser cooling, ultraslow group velocity propagation of light, etc. (Gao, 2009).

DOI
10.5772/35281

Related papers

Ultra-Sensitive Optical Atomic Magnetometers and Their Applications

Igor Savukov

Advances in Optical and Photonic Devices 330 integration into microfabricated packages.Such packages will be not only inexpensive and easy to batch produce they will also have lower power consumption, light weight and unimpeded mobility (Knappe et al., 2006).Sensitive magnetic field measurements, for which AMs can be used, are important owing to many existing and potential applications.Magnetometers have been in wide use, for example, in geology, military, biomagnetism, space magnetic field measurements.AMs have been used because they are both relatively sensitive compared to conventional inexpensive magnetometers, such as fluxgates, and more convenient compared to SQUIDs that require cryogenic cooling.For a long time low-T c SQUIDs had been by far the most sensitive magnetometers at low frequency.However, this has changed with the demonstration with AMs of record 0.5 fT/Hz 1/2 sensitivity (Kominis et al., 2003).High-sensitivity AMs are based on spin-polarized atomic gases or vapors, and AM research is closely related to the atomic physics subfield dedicated to the investigation of spin interactions in such media.This subfield includes the research on optical pumping and related topics such as atomic clocks, masers, hyperpolarized gases, spin-based spectroscopy, and some others.A comprehensive review of optical pumping experiments before 1972 and theory of optical pumping and various relaxation mechanisms are given by William Happer (Happer, 1972).This theory, which still stands the test of time, includes the formulation of density matrix equations, which can be directly applied to the analysis of magnetic resonances of vapors on which atomic magnetometers are based.Atomic magnetometers find many applications as other magnetometers, but they are most useful when high sensitivity and non-cryogenic operation are required.For example, AMs have been developed for submarine detection, and many other military applications are possible on similar principles.Some applications of Rb-vapor or 3 He magnetometers in geophysics and space physics were mentioned as early as in 1961 by Bloom (Bloom, 1961) who did some pioneering work on the high-sensitivity measurements of magnetic fields and theory for the operation of atomic magnetometers.Theoretical analysis of early atomic magnetometers was also done by Dehmelt (Dehmelt, 1957) and by Bell and Bloom (Bell & Bloom, 1957).Although the history of atomic magnetometers is quite fascinating and they played an important role in applications where simpler and less expensive methods did not provide sufficient sensitivity, the atomic magnetometers of the past were much less sensitive than the modern ones.Most exciting results appeared only recently with the various demonstrations of performance of high-density AMs, which we would like to focus on in this chapter. How to referenceIn order to correctly reference this scholarly work, feel free to copy and paste the following: Igor Savukov (2010).Ultra-Sensitive Optical Atomic Magnetometers and Their Applications, Advances in Optical and Photonic Devices, Ki Young Kim (Ed.),

InTech eBooks•Jan 1, 2010•11 citations

Optical atomic magnetometry

Wojciech Gawlik, Szymon Pustelny

This work presents new methods of optical magnetometry developed in the Center for Magneto-Optical Research at the Jagiellonian University. Using rubidium atoms contained in cm-long glass cells and amplitude-modulated laser we have recorded magneto-optical signals of extremely small widths. These signals allow measurements of magnetic fields with a sensitivity comparable to that achieved with magnetometers based on Superconducting Quantum Interference Devices (SQUIDs). Full Text: PDF References: M. Faraday,Experimental Researches in Electricity. Nineteenth Series, Trans. R. Soc. London 136, 1 (1846). [CrossRef] K. Barczak and S. Pustelny,Magnetooptic properties of special optical type D fibers, J. Phys. IV 137, 15 (2006). [CrossRef] W. Gawlik, J. Kowalski, R. Neumann, and F. Trager, Observation of the electric hexadecapole moment of free Na atoms in a forward scattering experiment, Opt. Commun. 12, 400 (1974). [CrossRef] W. Gawlik, S. Pustelny, in New Trends in Quantum Coherence and Optics, R. Drampyan Ed., 47 (New York, Nova Publishers, 2009). D. W. Gawlik, D. F. Kimball, S. M. Rochester, A. Weis, and V. V. Yashchuk,Resonant nonlinear magneto-optical effects in atoms, Rev. Mod. Phys. 74, 1153 (2002). [CrossRef] D. V.V. Yashchuk, and M. Zolotorev,Nonlinear Magneto-optic Effects with Ultranarrow Widths, Phys. Rev. Lett. 81(26), 5788 (1998). [CrossRef] D. D. F. Kimball, S. M. Rochester, V. V. Yashchuk, and M. Zolotorev,Sensitive magnetometry based on nonlinear magneto-optical rotation, Phys. Rev. A 62, 043403 (2000). [CrossRef] G. Wąsik, W. Gawlik, J. Zachorowski, and W. Zawadzki, Laser frequency stabilization by Doppler-free magnetic dichroism, Appl. Phys. B 75, 613 (2002). [CrossRef] W. Gawlik, L. Krzemien, S. Pustelny, D. Sangla, J. Zachorowski, M. Graf, A. O. Sushkov, and D. Budker, magneto-optical rotation with amplitude modulated light, Appl. Phys. Lett. 88 131108 (2006). [CrossRef] D. D. F. Kimball, V. V. Yashchuk, M. Zolotorev,Nonlinear magneto-optical rotation with frequency-modulated light, Phys. Rev. A 65, 055403 (2002). [CrossRef] J. M. Higbie, E. Corsini, and D. Robust, high-speed, all-optical atomic magnetometer, Rev. Sci. Instr. 77, 113106 (2006). [CrossRef] S. Pustelny, A. Wojciechowski, M. Kotyrba, K. Sycz, J. Zachorowski, W. Gawlik, A. Cingoz, N. Leefer, J. M. Higbie, E. Corsini, M. P. Ledbetter, S. M. Rochester, A. O. Sushkov, and D. All-optical atomic magnetometers based on nonlinear magneto-optical rotation with amplitude modulated light, Proc. of SPIE 6604, 660404 (2007). [CrossRef] S. Pustelny, A. Wojciechowski, M. Gring, M. Kotyrba, J. Zachorowski, W. Gawlik, Magnetometry based on nonlinear magneto-optical rotation with amplitude-modulated light, J. Appl. Phys. 103, 063108 (2008). [CrossRef] S. Pustelny, S. M. Rochester, D. F. Jackson Kimball, V. V. Yashchuk, D. and W. Gawlik, Nonlinear magneto-optical rotation with modulated light in tilted magnetic fields, Phys. Rev. A 74, 063420 (2006). [CrossRef]

Photonics Letters of Poland•Mar 28, 2009•0 citations

High Sensitivity Atomic Magnetometers and Their Applications

Michael V. Romalis

I will review recent progress in optical magnetometry techniques using spin-polarized alkali-metal atoms and discuss their applications for detection of nuclear magnetic resonance, biological magnetic fields, rotation sending, and fundamental physics tests.

Frontiers in Optics•Jan 1, 2007•0 citations

The Saga of Light-Matter Interaction and Magneto-optical Effects Applications to Atomic Magnetometry, Laser-cooled Atoms, Atomic Clocks, Geomagnetism, and Plant Bio-magnetism

Eric Corsini

The quest to expand the limited sensorial domain, in particular to bridge the inability to gauge magnetic fields near and far, has driven the fabrication of remedial tools. The interaction of ferromagnetic material with a magnetic field had been the only available technique to gauge that field for several millennium. The advent of electricity and associated classical phenomena captured in the four Maxwell equations, were a step forward. In the early 1900s, the model of quantum mechanics provided a two-way leap forward. One came from the newly understood interaction of light and matter, and more specifically the three-way coupling of photons, atoms' angular momenta, and magnetic field, which are the foundations of atomic magnetometry. The other came from magnetically sensitive quantum effects in a fabricated energy-ladder form of matter cooled to a temperature below that of the energy steps; these quantum effects gave rise to the superconducting quantum interference device (SQUID). Research using atomic magnetometers and SQUIDs has resulted in thousands of publications, text books, and conferences. The current status in each field is well described in Refs. [48,49,38,42] and all references therein. In this work we develop and investigate techniques and applications pertaining to atomic magnetometry. [Full text: eric.corsini@gmail.com]

•Jan 1, 2012•0 citations

Research progress on high-sensitivity chip-scale atomic magnetometers

Hao Liu, liu lin, Xiaodong Han +1 more

As one of the fundamental properties of matter, magnetic fields have extensive application value in fields such as military, medical, and industrial sectors. High-sensitivity magnetic field measurement technology is crucial for exploring the physical world, ensuring national security, and promoting industrial development. Traditional magnetic sensors based on classical physics principles, such as fluxgate and Hall effect sensors, have become increasingly difficult to meet growing demands in terms of sensitivity, volume, and power consumption. In contrast, atomic magnetometers based on quantum effects utilize the interaction between atomic spins and external magnetic fields for measurement, offering advantages such as high sensitivity, no requirement for cryogenic cooling, and the capability for absolute measurement, making them a novel type of magnetic sensor that has received significant attention in recent years. In particular, the development of chip-scale atomic magnetometers, through technologies such as Micro-Electro-Mechanical Systems (MEMS), has significantly reduced the volume and power consumption of atomic magnetometers, enabling them to demonstrate tremendous application potential in fields such as ocean exploration, biomedical applications, and geological exploration. This paper will review the technological advances of high-sensitivity chip-scale atomic magnetometers, with a focus on discussing the latest achievements in their miniaturization and small-scale research.

Sixth Symposium on Novel Optoelectronic Detection Technology and Applications•May 11, 2026•0 citations

Harmonic detection of magnetic resonance for sensitivity improvement of optical atomic magnetometers

Maliheh Ranjbaran, Mohammad Mehdi Tehranchi, Seyedeh Mehri Hamidi +1 more

Journal of Magnetism and Magnetic Materials•Oct 16, 2016•19 citations
There has been permanent interest in investigations of new magnetic sensors and their various applications (Edelstein, 2007). Last years there is a rapid progress in development of magneto-optical sensors because of their sensitivity and potential for miniaturization. Magnetometers, based on magneto-optical sensors have high sensitivity comparable to, or even surpassing this of the SQUIDs (Superconducting Quantum Interference Devices) (Kominis et al., 2003; Dang et al., 2010; Savukov, 2010; Knappe, 2010). Microfabrication of components using the techniques of Micro-Electro-Mechanical Systems (MEMS) developed for atomic clocks (Knappe, 2004) gives the opportunity for building small, low consuming, low cost and non-cryogenic (as SQUIDs) sensors (Griffith et al., 2010). Coherent optical effects can be applied for magnetic field detection and offer perspectives for development of high-precision optical magnetometers (Cox et al., 2011; Kitching et al., 2011). These magnetometers are appropriate for geomagnetic, space, nuclear and biological magnetic field measurements (cardio and brain magnetic field imaging), environmental monitoring, magnetic microscopy, investigations of fundamental physics, etc. Coherent magneto-optical resonances have many applications not only in magnetometry, but in high-resolution spectroscopy, lasing without inversion, laser cooling, ultraslow group velocity propagation of light, etc. (Gao, 2009).
Advances in Optical and Photonic Devices 330 integration into microfabricated packages.Such packages will be not only inexpensive and easy to batch produce they will also have lower power consumption, light weight and unimpeded mobility (Knappe et al., 2006).Sensitive magnetic field measurements, for which AMs can be used, are important owing to many existing and potential applications.Magnetometers have been in wide use, for example, in geology, military, biomagnetism, space magnetic field measurements.AMs have been used because they are both relatively sensitive compared to conventional inexpensive magnetometers, such as fluxgates, and more convenient compared to SQUIDs that require cryogenic cooling.For a long time low-T c SQUIDs had been by far the most sensitive magnetometers at low frequency.However, this has changed with the demonstration with AMs of record 0.5 fT/Hz 1/2 sensitivity (Kominis et al., 2003).High-sensitivity AMs are based on spin-polarized atomic gases or vapors, and AM research is closely related to the atomic physics subfield dedicated to the investigation of spin interactions in such media.This subfield includes the research on optical pumping and related topics such as atomic clocks, masers, hyperpolarized gases, spin-based spectroscopy, and some others.A comprehensive review of optical pumping experiments before 1972 and theory of optical pumping and various relaxation mechanisms are given by William Happer (Happer, 1972).This theory, which still stands the test of time, includes the formulation of density matrix equations, which can be directly applied to the analysis of magnetic resonances of vapors on which atomic magnetometers are based.Atomic magnetometers find many applications as other magnetometers, but they are most useful when high sensitivity and non-cryogenic operation are required.For example, AMs have been developed for submarine detection, and many other military applications are possible on similar principles.Some applications of Rb-vapor or 3 He magnetometers in geophysics and space physics were mentioned as early as in 1961 by Bloom (Bloom, 1961) who did some pioneering work on the high-sensitivity measurements of magnetic fields and theory for the operation of atomic magnetometers.Theoretical analysis of early atomic magnetometers was also done by Dehmelt (Dehmelt, 1957) and by Bell and Bloom (Bell & Bloom, 1957).Although the history of atomic magnetometers is quite fascinating and they played an important role in applications where simpler and less expensive methods did not provide sufficient sensitivity, the atomic magnetometers of the past were much less sensitive than the modern ones.Most exciting results appeared only recently with the various demonstrations of performance of high-density AMs, which we would like to focus on in this chapter. How to referenceIn order to correctly reference this scholarly work, feel free to copy and paste the following: Igor Savukov (2010).Ultra-Sensitive Optical Atomic Magnetometers and Their Applications, Advances in Optical and Photonic Devices, Ki Young Kim (Ed.),
This work presents new methods of optical magnetometry developed in the Center for Magneto-Optical Research at the Jagiellonian University. Using rubidium atoms contained in cm-long glass cells and amplitude-modulated laser we have recorded magneto-optical signals of extremely small widths. These signals allow measurements of magnetic fields with a sensitivity comparable to that achieved with magnetometers based on Superconducting Quantum Interference Devices (SQUIDs). Full Text: PDF References: M. Faraday,Experimental Researches in Electricity. Nineteenth Series, Trans. R. Soc. London 136, 1 (1846). [CrossRef] K. Barczak and S. Pustelny,Magnetooptic properties of special optical type D fibers, J. Phys. IV 137, 15 (2006). [CrossRef] W. Gawlik, J. Kowalski, R. Neumann, and F. Trager, Observation of the electric hexadecapole moment of free Na atoms in a forward scattering experiment, Opt. Commun. 12, 400 (1974). [CrossRef] W. Gawlik, S. Pustelny, in New Trends in Quantum Coherence and Optics, R. Drampyan Ed., 47 (New York, Nova Publishers, 2009). D. W. Gawlik, D. F. Kimball, S. M. Rochester, A. Weis, and V. V. Yashchuk,Resonant nonlinear magneto-optical effects in atoms, Rev. Mod. Phys. 74, 1153 (2002). [CrossRef] D. V.V. Yashchuk, and M. Zolotorev,Nonlinear Magneto-optic Effects with Ultranarrow Widths, Phys. Rev. Lett. 81(26), 5788 (1998). [CrossRef] D. D. F. Kimball, S. M. Rochester, V. V. Yashchuk, and M. Zolotorev,Sensitive magnetometry based on nonlinear magneto-optical rotation, Phys. Rev. A 62, 043403 (2000). [CrossRef] G. Wąsik, W. Gawlik, J. Zachorowski, and W. Zawadzki, Laser frequency stabilization by Doppler-free magnetic dichroism, Appl. Phys. B 75, 613 (2002). [CrossRef] W. Gawlik, L. Krzemien, S. Pustelny, D. Sangla, J. Zachorowski, M. Graf, A. O. Sushkov, and D. Budker, magneto-optical rotation with amplitude modulated light, Appl. Phys. Lett. 88 131108 (2006). [CrossRef] D. D. F. Kimball, V. V. Yashchuk, M. Zolotorev,Nonlinear magneto-optical rotation with frequency-modulated light, Phys. Rev. A 65, 055403 (2002). [CrossRef] J. M. Higbie, E. Corsini, and D. Robust, high-speed, all-optical atomic magnetometer, Rev. Sci. Instr. 77, 113106 (2006). [CrossRef] S. Pustelny, A. Wojciechowski, M. Kotyrba, K. Sycz, J. Zachorowski, W. Gawlik, A. Cingoz, N. Leefer, J. M. Higbie, E. Corsini, M. P. Ledbetter, S. M. Rochester, A. O. Sushkov, and D. All-optical atomic magnetometers based on nonlinear magneto-optical rotation with amplitude modulated light, Proc. of SPIE 6604, 660404 (2007). [CrossRef] S. Pustelny, A. Wojciechowski, M. Gring, M. Kotyrba, J. Zachorowski, W. Gawlik, Magnetometry based on nonlinear magneto-optical rotation with amplitude-modulated light, J. Appl. Phys. 103, 063108 (2008). [CrossRef] S. Pustelny, S. M. Rochester, D. F. Jackson Kimball, V. V. Yashchuk, D. and W. Gawlik, Nonlinear magneto-optical rotation with modulated light in tilted magnetic fields, Phys. Rev. A 74, 063420 (2006). [CrossRef]
The quest to expand the limited sensorial domain, in particular to bridge the inability to gauge magnetic fields near and far, has driven the fabrication of remedial tools. The interaction of ferromagnetic material with a magnetic field had been the only available technique to gauge that field for several millennium. The advent of electricity and associated classical phenomena captured in the four Maxwell equations, were a step forward. In the early 1900s, the model of quantum mechanics provided a two-way leap forward. One came from the newly understood interaction of light and matter, and more specifically the three-way coupling of photons, atoms' angular momenta, and magnetic field, which are the foundations of atomic magnetometry. The other came from magnetically sensitive quantum effects in a fabricated energy-ladder form of matter cooled to a temperature below that of the energy steps; these quantum effects gave rise to the superconducting quantum interference device (SQUID). Research using atomic magnetometers and SQUIDs has resulted in thousands of publications, text books, and conferences. The current status in each field is well described in Refs. [48,49,38,42] and all references therein. In this work we develop and investigate techniques and applications pertaining to atomic magnetometry. [Full text: eric.corsini@gmail.com]
As one of the fundamental properties of matter, magnetic fields have extensive application value in fields such as military, medical, and industrial sectors. High-sensitivity magnetic field measurement technology is crucial for exploring the physical world, ensuring national security, and promoting industrial development. Traditional magnetic sensors based on classical physics principles, such as fluxgate and Hall effect sensors, have become increasingly difficult to meet growing demands in terms of sensitivity, volume, and power consumption. In contrast, atomic magnetometers based on quantum effects utilize the interaction between atomic spins and external magnetic fields for measurement, offering advantages such as high sensitivity, no requirement for cryogenic cooling, and the capability for absolute measurement, making them a novel type of magnetic sensor that has received significant attention in recent years. In particular, the development of chip-scale atomic magnetometers, through technologies such as Micro-Electro-Mechanical Systems (MEMS), has significantly reduced the volume and power consumption of atomic magnetometers, enabling them to demonstrate tremendous application potential in fields such as ocean exploration, biomedical applications, and geological exploration. This paper will review the technological advances of high-sensitivity chip-scale atomic magnetometers, with a focus on discussing the latest achievements in their miniaturization and small-scale research.