Optical lattice clock with ultracold strontium atoms

Martin M. Boyd, Andrew D. Ludlow, Tanya Zelevinsky, Seth M. Foreman, Sebastian Blatt, T. Ido, J. Ye

Published Mar 27, 2006• 0 citations
OpenAlex

Abstract

We report recent progress on an optical atomic clock based on the ultranarrow 1S 0 -3P 0 transition in fermionic neutral strontium atoms confined in an optical lattice. A detailed systematic study of the clock transition frequency is presented along with the recent improvement in the measured line quality factor which is expected to lead to an accuracy of 10−15 or better in the near future.

Related papers

Strontium optical lattice clock with high accuracy and stability

Jan W. Thomsen, Gretchen K. Campbell, Andrew D. Ludlow +6 more

Techniques of modern quantum optics allows for the preparation of atoms in well controlled quantum states ideal for precision measurements and tests of fundamental laws of physics. We report on our recent progress with a highly stable and accurate optical atomic clock based on ultracold fermionic87Sr atoms confined in a one dimensional optical lattice. Currently, we have carried out a detailed evaluation of our clock at the 10−16level and can report stability at 2 x 10−15level at one second. At typical operating parameters for the clock we observe evidence of a density dependent clock shift. Operating the clock at a particular excitation ratio of ground state and excited clock state we observe a shift consistent with zero.

Conference on Precision Electromagnetic Measurements•Jun 1, 2008•2 citations

High Precision Spectroscopy of Strontium in an Optical Lattice: Towards a New Standard for Frequency and Time

Martin M. Boyd

Clocks based on optical transitions in ions and atoms are quickly moving to the forefront of the frequency standards field mainly because of the high spec-tral resolution, and therefore the potential stability and accuracy, which can be achieved. In this thesis a new optical clock based on neutral atoms trapped in an optical lattice is presented, demonstrating spectroscopy of the clock transition free of any lineshape or accuracy degradation due to atomic motion. The system simu-lates a single trapped ion clock, but allows use of thousands of atoms for improved signal to noise ratio, and clock stability. High accuracy can also be achieved as the lattice can be designed to shift the energy of the two atomic clock states equally, such that the transition frequency is unchanged. Strontium is a natural candidate for such a clock as it offers an extremely narrow optical transition (∼1 mHz) based on atomic states which are very insensitive to external fields. The strontium level structure allows efficient laser cooling to 1 µK with diode laser sources, and a con-venient wavelength of 813 nm for the zero-differential Stark shift optical lattice. The strontium lattice clock system has allowed observation of high signal-to-noise

•Jan 1, 2007•36 citations

Progress towards a strontium optical lattice clock at NPL

Elizabeth M. Bridge, Ian R. Hill, Yuri B. Ovchinnikov +3 more

The1S0-3P0transition at 698 nm in neutral strontium has the potential to be an extremely precise optical frequency standard [1] and is one of several candidates for a future redefinition of the second. Recent measurements of this transition at three national laboratories around the world have fractional frequency uncertainties in the 1015range and agree to within a hertz [2,3,4]. To realise fully the potential accuracy of this frequency standard, in depth studies of systematic effects need to be performed in order to characterise them at the level necessary for a redefinition of the second. At the National Physical Laboratory we are developing a compact, diode laser based optical lattice clock. We intend to study the clock transition in both88Sr and87Sr with focus on the uncertainties in the frequency shifts due to blackbody radiation. The setup incorporates a novel permanent magnet based Zeeman slower [5].

European Frequency and Time Forum•Apr 1, 2010•0 citations

Optical frequency standard with ultra-cold strontium atoms

N. Poli, Robert E. Drullinger, Marco G. Tarallo +2 more

We report on our progress toward the realization of an optical frequency standard referenced to strontium intercombination lines. While first frequency measurement of the weakly allowed 1S 0- 3P 1 transition was done with saturation spectroscopy on a thermal beam, we are preparing the experimental setup for high resolution spectroscopy on ultracold atoms of the doubly forbidden 1S 0- 3P 0 line. Our current setup allows the capture more than 10 7 atoms at 1 μK in 500 ms in two stages of magneto-optical trapping. We also demonstrated the dipole trapping of ultracold strontium isotopes for accurate spectroscopy and collisional measurements. A semiconductor laser source at 698 nm has already been locked to a pre-stabilization cavity obtaining a fast linewidth of less than 1 kHz. Second stage stabilization of the clock laser to ultra-high finesse cavity is in development. Recent measurement of elastic and inelastic cross-sections of the two most abundant 88Sr and 86Sr isotopes are also presented.

•Jan 1, 2006•2 citations

Clock with 8 × 10 − 19 Systematic Uncertainty

Alexander Aeppli, Kyungtae Kim, William Warfield +2 more

We report an optical lattice clock with a total systematic uncertainty of 8.1×10^{-19} in fractional frequency units, representing the lowest uncertainty of any clock to date. The clock relies on interrogating the ultranarrow ^{1}S_{0}→^{3}P_{0} transition in a dilute ensemble of fermionic strontium atoms trapped in a vertically-oriented, shallow, one-dimensional optical lattice. Using imaging spectroscopy, we previously demonstrated record high atomic coherence time and measurement precision enabled by precise control of collisional shifts and the lattice light shift. In this work, we revise the black body radiation shift correction by evaluating the 5s4d ^{3}D_{1} lifetime, necessitating precise characterization and control of many body effects in the 5s4d ^{3}D_{1} decay. Last, we measure the second order Zeeman coefficient on the least magnetically sensitive clock transition. All other systematic effects have uncertainties below 1×10^{-19}.

arXiv:2403.10664•Physical Review Letters•Jul 10, 2024•211 citations

An optical lattice clock with neutral strontium

Richard Hobson

Strontium optical lattice clocks can measure the passage of time with extraordinary precision. Capitalising on this precision, we can anticipate the deployment of lattice clocks to search for new physics beyond the standard model, to build new technologies for geodesy and navigation, and potentially to underpin a future redenition of the SI second. This thesis reports on the construction and evaluation of a robust Sr optical lattice clock at NPL. We describe the apparatus needed to capture, cool, and load samples of neutral strontium atoms into a magic-wavelength, far off-resonant lattice trap at 813 nm. We provide details of our optical local oscillator - the "clock laser" - and how it is used to realise an Sr-referenced optical frequency standard. We rigorously characterise the various contributing factors which limit the performance of the clock, focusing on the standard measures of (1) frequency instability, and (2) systematic frequency uncertainty. Finally, we introduce new innovations for improving the accuracy of the 88Sr lattice clock, including methods of "modified hyper-Ramsey" and multi-photon spectroscopy of the clock transition.

•Jan 1, 2016•8 citations
We report recent progress on an optical atomic clock based on the ultranarrow 1S 0 -3P 0 transition in fermionic neutral strontium atoms confined in an optical lattice. A detailed systematic study of the clock transition frequency is presented along with the recent improvement in the measured line quality factor which is expected to lead to an accuracy of 10−15 or better in the near future.
Techniques of modern quantum optics allows for the preparation of atoms in well controlled quantum states ideal for precision measurements and tests of fundamental laws of physics. We report on our recent progress with a highly stable and accurate optical atomic clock based on ultracold fermionic87Sr atoms confined in a one dimensional optical lattice. Currently, we have carried out a detailed evaluation of our clock at the 10−16level and can report stability at 2 x 10−15level at one second. At typical operating parameters for the clock we observe evidence of a density dependent clock shift. Operating the clock at a particular excitation ratio of ground state and excited clock state we observe a shift consistent with zero.
Clocks based on optical transitions in ions and atoms are quickly moving to the forefront of the frequency standards field mainly because of the high spec-tral resolution, and therefore the potential stability and accuracy, which can be achieved. In this thesis a new optical clock based on neutral atoms trapped in an optical lattice is presented, demonstrating spectroscopy of the clock transition free of any lineshape or accuracy degradation due to atomic motion. The system simu-lates a single trapped ion clock, but allows use of thousands of atoms for improved signal to noise ratio, and clock stability. High accuracy can also be achieved as the lattice can be designed to shift the energy of the two atomic clock states equally, such that the transition frequency is unchanged. Strontium is a natural candidate for such a clock as it offers an extremely narrow optical transition (∼1 mHz) based on atomic states which are very insensitive to external fields. The strontium level structure allows efficient laser cooling to 1 µK with diode laser sources, and a con-venient wavelength of 813 nm for the zero-differential Stark shift optical lattice. The strontium lattice clock system has allowed observation of high signal-to-noise
The1S0-3P0transition at 698 nm in neutral strontium has the potential to be an extremely precise optical frequency standard [1] and is one of several candidates for a future redefinition of the second. Recent measurements of this transition at three national laboratories around the world have fractional frequency uncertainties in the 1015range and agree to within a hertz [2,3,4]. To realise fully the potential accuracy of this frequency standard, in depth studies of systematic effects need to be performed in order to characterise them at the level necessary for a redefinition of the second. At the National Physical Laboratory we are developing a compact, diode laser based optical lattice clock. We intend to study the clock transition in both88Sr and87Sr with focus on the uncertainties in the frequency shifts due to blackbody radiation. The setup incorporates a novel permanent magnet based Zeeman slower [5].
We report on our progress toward the realization of an optical frequency standard referenced to strontium intercombination lines. While first frequency measurement of the weakly allowed 1S 0- 3P 1 transition was done with saturation spectroscopy on a thermal beam, we are preparing the experimental setup for high resolution spectroscopy on ultracold atoms of the doubly forbidden 1S 0- 3P 0 line. Our current setup allows the capture more than 10 7 atoms at 1 μK in 500 ms in two stages of magneto-optical trapping. We also demonstrated the dipole trapping of ultracold strontium isotopes for accurate spectroscopy and collisional measurements. A semiconductor laser source at 698 nm has already been locked to a pre-stabilization cavity obtaining a fast linewidth of less than 1 kHz. Second stage stabilization of the clock laser to ultra-high finesse cavity is in development. Recent measurement of elastic and inelastic cross-sections of the two most abundant 88Sr and 86Sr isotopes are also presented.
We report an optical lattice clock with a total systematic uncertainty of 8.1×10^{-19} in fractional frequency units, representing the lowest uncertainty of any clock to date. The clock relies on interrogating the ultranarrow ^{1}S_{0}→^{3}P_{0} transition in a dilute ensemble of fermionic strontium atoms trapped in a vertically-oriented, shallow, one-dimensional optical lattice. Using imaging spectroscopy, we previously demonstrated record high atomic coherence time and measurement precision enabled by precise control of collisional shifts and the lattice light shift. In this work, we revise the black body radiation shift correction by evaluating the 5s4d ^{3}D_{1} lifetime, necessitating precise characterization and control of many body effects in the 5s4d ^{3}D_{1} decay. Last, we measure the second order Zeeman coefficient on the least magnetically sensitive clock transition. All other systematic effects have uncertainties below 1×10^{-19}.
Strontium optical lattice clocks can measure the passage of time with extraordinary precision. Capitalising on this precision, we can anticipate the deployment of lattice clocks to search for new physics beyond the standard model, to build new technologies for geodesy and navigation, and potentially to underpin a future redenition of the SI second. This thesis reports on the construction and evaluation of a robust Sr optical lattice clock at NPL. We describe the apparatus needed to capture, cool, and load samples of neutral strontium atoms into a magic-wavelength, far off-resonant lattice trap at 813 nm. We provide details of our optical local oscillator - the "clock laser" - and how it is used to realise an Sr-referenced optical frequency standard. We rigorously characterise the various contributing factors which limit the performance of the clock, focusing on the standard measures of (1) frequency instability, and (2) systematic frequency uncertainty. Finally, we introduce new innovations for improving the accuracy of the 88Sr lattice clock, including methods of "modified hyper-Ramsey" and multi-photon spectroscopy of the clock transition.