Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

中国物理B:英文版

Deceleration of a continuous-wave (CW) molecular beam with a single quasi-CW semi-Gaussian laser beam

尹亚玲, Yong Xia, 印建平

Published Jan 1, 2008• 0 citations
OpenAlex

Related papers

Decelerating a pulsed subsonic molecular beam by a quasi-cw optical lattice: 3D Monte-Carlo simulations

Xiang Ji, Yaling Yin, Qi Zhou +2 more

Optics Communications•Sep 24, 2012•4 citations

Deceleration of a continuous-wave (CW) molecular beam with a single quasi-CW semi-Gaussian laser beam

Yin Ya-Ling, Yong Xia, Yin Jian-Ping

We propose a promising scheme to decelerate a CW molecular beam by using a red-detuned quasi-cw semi-Gaussian laser beam (SGB). We study the dynamical process of the deceleration for a CW deuterated ammonia (ND 3 ) molecular beam by Monte–Carlo simulation method. Our study shows that we can obtain a ND 3 molecular beam with a relative average kinetic energy loss of about 10% and a relative output molecular number of more than 90% by using a single quasi-cw SGB with a power of 1.5kW and a maximum optical well depth of 7.33mK.

Chinese Physics B•Oct 1, 2008•6 citations

Controlling amplitude and phase of a laser beam by a single molecule

M. Pototschnig

•Jan 1, 2011•3 citations

Optical Stark decelerator for cw molecular beam with a quasi-cw semi-Gaussian laser beam

Yaling Yin, Yong Xia, Jianping Yin

We propose a promising scheme to decelerate a cw filtering out molecular beam using a red-detuned quasi-cw semi-Gaussian laser beam. By using Monte-Carlo simulation method, we demonstrate this optical Stark deceleration scheme, and study its decelerated dynamic process for a cw ND3 molecular beam as well as the dependence of the deceleration effect on the border width of the semi-Gaussian beam. Our study shows that the proposed scheme can be used to efficiently slow a cw ND3 molecular beam, and obtain a relative average kinetic-energy loss of 9.33% by using a single semi-Gaussian beam with a well depth of 7.3 mK.

arXiv:0803.0790•Mar 6, 2008•0 citations

A Multistage Optical Stark Decelerator for use with a Pulsed Molecular Beam with an Electrostatic Storage Ring

Yong Xia, Yaling Yin, Xiang Ji +1 more

We propose a promising scheme to repeatedly decelerate a pulsed molecular beam using a red-detuned quasi-cw semi-Gaussian laser beam (SGB) and an electrostatic storage ring. Using the Monte-Carlo simulation method, we demonstrate that this promising optical Stark decelerator can be used to efficiently slow a pulsed ND 3 molecular beam extracted from a Stark decelerator or a cryogenic reservoir by using a single SGB. The deceleration effect of this scheme on the intensity of the SGB is discussed in detail.

Chinese Physics Letters•May 1, 2012•7 citations

Mode-Locked Deceleration of Molecular Beams: Physics with Ultracold Molecules

Wesley C. Campbell

•Feb 7, 2017•0 citations
We propose a promising scheme to decelerate a CW molecular beam by using a red-detuned quasi-cw semi-Gaussian laser beam (SGB). We study the dynamical process of the deceleration for a CW deuterated ammonia (ND 3 ) molecular beam by Monte–Carlo simulation method. Our study shows that we can obtain a ND 3 molecular beam with a relative average kinetic energy loss of about 10% and a relative output molecular number of more than 90% by using a single quasi-cw SGB with a power of 1.5kW and a maximum optical well depth of 7.33mK.
We propose a promising scheme to decelerate a cw filtering out molecular beam using a red-detuned quasi-cw semi-Gaussian laser beam. By using Monte-Carlo simulation method, we demonstrate this optical Stark deceleration scheme, and study its decelerated dynamic process for a cw ND3 molecular beam as well as the dependence of the deceleration effect on the border width of the semi-Gaussian beam. Our study shows that the proposed scheme can be used to efficiently slow a cw ND3 molecular beam, and obtain a relative average kinetic-energy loss of 9.33% by using a single semi-Gaussian beam with a well depth of 7.3 mK.
We propose a promising scheme to repeatedly decelerate a pulsed molecular beam using a red-detuned quasi-cw semi-Gaussian laser beam (SGB) and an electrostatic storage ring. Using the Monte-Carlo simulation method, we demonstrate that this promising optical Stark decelerator can be used to efficiently slow a pulsed ND 3 molecular beam extracted from a Stark decelerator or a cryogenic reservoir by using a single SGB. The deceleration effect of this scheme on the intensity of the SGB is discussed in detail.