Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Wuli yu gongcheng.

超导量子干涉器(SQUID)原理及应用

倪小静, 杨超云

Published Jan 1, 2007• 0 citations
OpenAlex

Related papers

Continuous feedback operation of a two-stage dc SQUID system

Insik Jin, F. C. Wellstood

We report on the continuous feedback operation of a two-stage dc Superconducting Quantum Interference Device (SQUID) system in which one SQUID works as a low-noise preamplifier to read out a second low-noise sensor SQUID. We first flux-locked the readout SQUID and measured the characteristics of the sensor SQUID, including its current-voltage characteristics, current-flux characteristics, and noise spectrum. We then investigated how the two SQUIDs could work together by simultaneously flux-locking both the sensor and the readout SQUIDs. With this two-SQUID flux-locking scheme, we recovered the noise spectrum of the sensor SQUID to within 4%. We discuss how to understand and optimize the two-stage SQUID feedback system.

IEEE Transactions on Applied Superconductivity•Jun 1, 1999•3 citations

超伝導量子干渉素子(SQUID)技術の現状

弦 上原, 久 賀戸

応用物理•May 10, 1992•0 citations

经由超导量子干涉装置(SQUIDs)实现两比特相位门

张世军

考试周刊•Jan 1, 2012•0 citations

Bias conditions of dc-SQUID for a time-domain SQUID multiplexer

J. Beyer, D. Drung, K. D. Irwin

We have analyzed the biasing of the first-stage dc superconducting quantum interference devices (SQUIDs) of a time-domain dc-SQUID multiplexer (SQUID MUX) and find that the bias conditions of first-stage SQUIDs significantly affect the performance of the SQUID MUX in terms of total multiplexer noise and bandwidth. We present an experimental study of the operational parameters of a first-stage SQUID under varied bias conditions. Our measurements include a direct determination of the first-stage SQUID dynamic resistance RDYN1 and the flux noise of the first-stage SQUID biased over the range from voltage bias to current bias. Our measurements show that matching the bias resistors RS1 of the first-stage SQUIDs to RDYN1 improves the SQUID MUX noise performance as well as the first-stage bandwidth.

Review of Scientific Instruments•Jan 26, 2004•4 citations

rf-SQUID magnetometer biased by harmonic

Tsutomu Yamashita, Yutaka Onodera

This paper describes a refined rf-SQUID magnetometer in which not only the fabrication of the SQUID sensor becomes easier but also the magnetic flux could be stably measured with sufficient sensitivity at a wider range of temperatures compared with existing SQUID systems. Two frequency components are used in the proposed rf-SQUID magnetometer, one of which is to excite the SQUID sensor and the other is to detect its response. Furthermore, from both the phenomenological analysis and the experimental results it is shown that the present rf-SQUID magnetometer performs its function well even if the value of LIc of the SQUID sensor is much larger than the flux quantum φ0.

Journal of Applied Physics•Jul 1, 1979•1 citation

SQUID : 巨視的量子性(量子力学の基礎について,研究会報告)

敏三 藤田

素粒子論研究•Feb 20, 1984•0 citations
We report on the continuous feedback operation of a two-stage dc Superconducting Quantum Interference Device (SQUID) system in which one SQUID works as a low-noise preamplifier to read out a second low-noise sensor SQUID. We first flux-locked the readout SQUID and measured the characteristics of the sensor SQUID, including its current-voltage characteristics, current-flux characteristics, and noise spectrum. We then investigated how the two SQUIDs could work together by simultaneously flux-locking both the sensor and the readout SQUIDs. With this two-SQUID flux-locking scheme, we recovered the noise spectrum of the sensor SQUID to within 4%. We discuss how to understand and optimize the two-stage SQUID feedback system.
We have analyzed the biasing of the first-stage dc superconducting quantum interference devices (SQUIDs) of a time-domain dc-SQUID multiplexer (SQUID MUX) and find that the bias conditions of first-stage SQUIDs significantly affect the performance of the SQUID MUX in terms of total multiplexer noise and bandwidth. We present an experimental study of the operational parameters of a first-stage SQUID under varied bias conditions. Our measurements include a direct determination of the first-stage SQUID dynamic resistance RDYN1 and the flux noise of the first-stage SQUID biased over the range from voltage bias to current bias. Our measurements show that matching the bias resistors RS1 of the first-stage SQUIDs to RDYN1 improves the SQUID MUX noise performance as well as the first-stage bandwidth.
This paper describes a refined rf-SQUID magnetometer in which not only the fabrication of the SQUID sensor becomes easier but also the magnetic flux could be stably measured with sufficient sensitivity at a wider range of temperatures compared with existing SQUID systems. Two frequency components are used in the proposed rf-SQUID magnetometer, one of which is to excite the SQUID sensor and the other is to detect its response. Furthermore, from both the phenomenological analysis and the experimental results it is shown that the present rf-SQUID magnetometer performs its function well even if the value of LIc of the SQUID sensor is much larger than the flux quantum φ0.