Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Noise investigation on optical detection in a cesium beam clock with magnetic state selection

Chang Liu, Sheng Zhou, Yanhui Wang

Published Apr 1, 2015• 4 citations
Publisher

Abstract

Noise sources in optical detection of a magnetic-state-selection cesium beam clock are analyzed in this paper. Atomic shot noise, photon shot noise, laser frequency noise and stray light noise are considered. Experimental measurements and estimations of the noise magnitude are made.
DOI
10.1109/fcs.2015.7138889

Related papers

Light shift suppression with pulsed light detection in magnetic-state-selected cesium beam clocks

Yuanhao Li, Shaohang Xu, Sifei Chen +3 more

Light detection is widely used in atomic clocks. The simple detecting structure induces the light shift which influences the clock's long-term stability. We introduce a new method to suppress light shift by using pulsed light instead of continuous light to detect atomic states. Under a suitable pulsed sequence, the part of the atoms which do not simultaneously interact with light and microwave field are detected. We demonstrate the validity of our approach in a magnetic-state-selected cesium beam clock. Using a well-tuned sequence, the light shift coefficient is reduced by a factor of about 10, in comparison with the continuous light detection scheme. In a clock stability test with extra light power noise, the result shows good immunity of the method to laser power fluctuations. We also analyze the sources of the clock short-term stability degradation, including the Dick effect and the fact that a reduced number of atoms is detected in the pulsed detection case.

Optics Express•Oct 26, 2022•6 citations

A new magnetic state selection method in high-performance optically detected compact cesium beam clocks

Sifei Chen, Chen Liu, Lifeng Fan +4 more

We perform a new scheme of magnetic state selection in optically detected compact cesium beam clocks. Unlike the conventional method, we select atoms in the ground state |F = 4, mF ≠ -4⟩ by pointing the atomic collimator to the convex pole of the magnet realizing the two-wire magnetic field and detect atoms in |F = 3⟩ after interacting with the microwave field using a distributed feedback laser. The fluorescence background is greatly reduced as the inherent residual atoms |F = 4, mF = -4⟩ are avoided in this reversed scheme. The velocity distribution is narrowed, and the most probable velocity is decreased, since atomic trajectories are close to the weak-field region. We also investigate the relationship between the position of the atomic collimator and the distributions of the atomic beam, which is consistent with the Monte Carlo-based simulation model. By applying the reversed scheme and setting the deviated position of the collimator to 1.3 mm, the signal contrast is improved from 0.7 to 3, and the short-term frequency stability reaches 3.0 × 10-12 τ-1/2, nearly three times better than that of the high-performance version of Microsemi 5071A.

Review of Scientific Instruments•Apr 1, 2023•5 citations

Optical Pumped Cesium Atomic Clock With Multi-pole Magnet

Tianyu Liu, Duo Pan, Jingbiao Chen

We apply the multi-pole magnet to the optical pumped cesium atomic clock, which can focus the pumped cesium atoms before entering the microwave cavity. By reducing the spatial divergence of cesium atomic beam as well as the loss of magnetic state selection of cesium atoms, this system can improve the utilization efficiency of cesium atoms in cesium atomic clock by an order of magnitude. Thus the signal-to-noise ratio and the stability index of cesium clock can be improved.

Joint Conference of the IEEE International Frequency Control Symposium and International Symposium on Applications of Ferroelectrics (IFCS-ISAF)•Jul 1, 2020•2 citations

Optical state selection process with optical pumping in a cesium atomic fountain clock*

Lei Han, Fang Fang, Weiliang Chen +5 more

We propose and realize a new optical state selection method on a cesium atomic fountain clock by applying a two-laser 3–3′ optical pumping configuration to spin polarize atoms. The atoms are prepared in |F = 3, mF = 0〉 clock state with optical pumping directly after being launched up, followed by a pushing beam to push away the atoms remaining in the |F = 4〉 state. With a state selection efficiency exceeding 92%, this optical method can substitute the traditional microwave state selection, and helps to develop a more compact physical package. A Ramsey fringe has been achieved with this optical state selection method, and a contrast of 90% is obtained with a full width half maximum of 0.92 Hz. The short-term frequency stability of 6.8 × 10−14 (τ/s)−1/2 is acquired. In addition, the number of detected atoms is increased by a factor of 1.7 with the optical state selection.

Chinese Physics B•May 29, 2021•3 citations

Compact CW cold beam cesium atomic clock

Walter F. Buell, Bernardo Jaduszliwer

We present a novel cesium beam physics package, which uses optical techniques to combine the high signal-to-noise ratios achievable by optical pumping and beam brightening with the narrow linewidth allowed by a slow atomic beam. Our design can be realized in a compact, robust package suitable for space applications. Our approach differs from other laser-cooled clocks in that we use a cold-atom source that provides a continuous beam. We estimate the shot noise-limited stability that can be achieved with this physics package to be two to three orders of magnitude better than that of current compact cesium beam atomic clocks.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 22, 2003•4 citations

Study on the sensitivity of laser-pumped cesium atomic magnetometer

Nan Li, Huang Kai-Kai, Xuanhui Lu

A cesium atomic magnetometer based on laser-pumped rf resonance has been investigated and demonstrated experimentally. Atoms are polarized and pumped to dark states by circularly polarized light. When there exists a magnetic field, the corresponding magnetization will be precessing around the magnetic field at Larmor frequency. By means of adding a resonant rf magnetic field, the atoms will be depolarized and absorb photons again. By detecting the spectrum of the transmitted light, one can obtain the information about the external magnetic field. We build an 894nm external cavity diode laser with a frequency stabilization device, and a low noise magnetic field measurement environment. After the optimization of the magnetometer parameter and closed-loop measurement, an ultimate sensitivity of 19 fT/Hz1/2 and an intrinsic sensitivity of 1.8 pT/Hz1/2 have been achieved with the spatial resolution smaller than 2 cm.

Acta Physica Sinica•Jan 1, 2013•4 citations
Light detection is widely used in atomic clocks. The simple detecting structure induces the light shift which influences the clock's long-term stability. We introduce a new method to suppress light shift by using pulsed light instead of continuous light to detect atomic states. Under a suitable pulsed sequence, the part of the atoms which do not simultaneously interact with light and microwave field are detected. We demonstrate the validity of our approach in a magnetic-state-selected cesium beam clock. Using a well-tuned sequence, the light shift coefficient is reduced by a factor of about 10, in comparison with the continuous light detection scheme. In a clock stability test with extra light power noise, the result shows good immunity of the method to laser power fluctuations. We also analyze the sources of the clock short-term stability degradation, including the Dick effect and the fact that a reduced number of atoms is detected in the pulsed detection case.
We perform a new scheme of magnetic state selection in optically detected compact cesium beam clocks. Unlike the conventional method, we select atoms in the ground state |F = 4, mF ≠ -4⟩ by pointing the atomic collimator to the convex pole of the magnet realizing the two-wire magnetic field and detect atoms in |F = 3⟩ after interacting with the microwave field using a distributed feedback laser. The fluorescence background is greatly reduced as the inherent residual atoms |F = 4, mF = -4⟩ are avoided in this reversed scheme. The velocity distribution is narrowed, and the most probable velocity is decreased, since atomic trajectories are close to the weak-field region. We also investigate the relationship between the position of the atomic collimator and the distributions of the atomic beam, which is consistent with the Monte Carlo-based simulation model. By applying the reversed scheme and setting the deviated position of the collimator to 1.3 mm, the signal contrast is improved from 0.7 to 3, and the short-term frequency stability reaches 3.0 × 10-12 τ-1/2, nearly three times better than that of the high-performance version of Microsemi 5071A.
We propose and realize a new optical state selection method on a cesium atomic fountain clock by applying a two-laser 3–3′ optical pumping configuration to spin polarize atoms. The atoms are prepared in |F = 3, mF = 0〉 clock state with optical pumping directly after being launched up, followed by a pushing beam to push away the atoms remaining in the |F = 4〉 state. With a state selection efficiency exceeding 92%, this optical method can substitute the traditional microwave state selection, and helps to develop a more compact physical package. A Ramsey fringe has been achieved with this optical state selection method, and a contrast of 90% is obtained with a full width half maximum of 0.92 Hz. The short-term frequency stability of 6.8 × 10−14 (τ/s)−1/2 is acquired. In addition, the number of detected atoms is increased by a factor of 1.7 with the optical state selection.
We present a novel cesium beam physics package, which uses optical techniques to combine the high signal-to-noise ratios achievable by optical pumping and beam brightening with the narrow linewidth allowed by a slow atomic beam. Our design can be realized in a compact, robust package suitable for space applications. Our approach differs from other laser-cooled clocks in that we use a cold-atom source that provides a continuous beam. We estimate the shot noise-limited stability that can be achieved with this physics package to be two to three orders of magnitude better than that of current compact cesium beam atomic clocks.
A cesium atomic magnetometer based on laser-pumped rf resonance has been investigated and demonstrated experimentally. Atoms are polarized and pumped to dark states by circularly polarized light. When there exists a magnetic field, the corresponding magnetization will be precessing around the magnetic field at Larmor frequency. By means of adding a resonant rf magnetic field, the atoms will be depolarized and absorb photons again. By detecting the spectrum of the transmitted light, one can obtain the information about the external magnetic field. We build an 894nm external cavity diode laser with a frequency stabilization device, and a low noise magnetic field measurement environment. After the optimization of the magnetometer parameter and closed-loop measurement, an ultimate sensitivity of 19 fT/Hz1/2 and an intrinsic sensitivity of 1.8 pT/Hz1/2 have been achieved with the spatial resolution smaller than 2 cm.