Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics B

Miniaturized optical system for atomic fountain clock

Desheng Lü, Qiuzhi Qu, Bin Wang, Jian-Bo Zhao, Tang Li, Liang Liu, Yuzhu Wang

Published Jun 1, 2011• 6 citations
Publisher

Abstract

Using modularized components, we have built a miniaturized optical system for 87 Rb atomic fountain clock that is fitted on an 80 cm × 60 cm optical breadboard. Compared with the conventional optical setup on the table, our system is more compact, more robust and miniaturized. Taking advantage of this system, laser beams are transmitted through eight optical fibre patch cords from the optical breadboard to an ultra high vacuum system. This optical setup has operated for five months in our fountain system and required no alignment.

DOI
10.1088/1674-1056/20/6/063201

Related papers

Integrated design of a compact magneto-optical trap for space applications

Qiuzhi Qu, Bin Wang, Desheng Lü +5 more

In this Letter, we describe an optical assembly that is designed for the engineering application of the atomic laser cooling techniques.Using a folded optical path scheme, we have built a miniaturized, compact magneto-optical trap (CMOT) for an 87 Rb atomic fountain clock.Compared with the conventional magneto-optical traps used in other clocks, our system is more robust, more compact, more stable, and saves about 60% laser power.This optical setup has operated for about a year in our fountain system, passed the thermal cycle tests and the mechanical vibration and shock tests, and maintained a high performance without a need for realignment.

Chinese Optics Letters•Jan 1, 2015•10 citations

The optical system of the fountain clock

Xinliang Wang, Jun Ruan, Hui Zhang +7 more

This paper present an optical system for Cs atomic fountain clock that is located on a 1.2 m×1.2 m optical table. Taking advantage of this system, we trap about 108cesium atoms in the magneto-optic trap (MOT) and get the Ramsey fringe of the fountain by scanning the microwave frequency of the interrogation cavity. The full-width at half-maximum of the central fringe (FWHM) is 1.4 Hz.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2014•2 citations

A transportable optical lattice clock at the National Time Service Center*

Dehuan Kong, Zhi‐Hui Wang, Feng Guo +4 more

We report a transportable one-dimensional optical lattice clock based on 87Sr at the National Time Service Center. The transportable apparatus consists of a compact vacuum system and compact optical subsystems. The vacuum system with a size of 90 cm× 20 cm× 42 cm and the beam distributors are assembled on a double-layer optical breadboard. The modularized optical subsystems are integrated on independent optical breadboards. By using a 230 ms clock laser pulse, spin-polarized spectroscopy with a linewidth of 4.8 Hz is obtained which is close to the 3.9 Hz Fourier-limit linewidth. The time interleaved self-comparison frequency instability is determined to be 6.3 × 10–17 at an averaging time of 2000 s.

Chinese Physics B•May 13, 2020•20 citations

Compact laser modulation system for a transportable atomic gravimeter

Alejandra López-Vázquez, Mario A. Maldonado, E. Gómez +15 more

Nowadays, atom-based quantum sensors are leaving the laboratory towards field applications requiring compact and robust laser systems. Here we describe the realization of a compact laser system for atomic gravimetry. Starting with a single diode laser operating at 780 nm and adding only one fiber electro-optical modulator, one acousto-optical modulator and one laser amplifier we produce laser beams at all the frequencies required for a Rb-87 atomic gravimeter. Furthermore, we demonstrate that an atomic fountain configuration can also be implemented with our laser system. The modulated system reported here represents a substantial advance in the simplification of the laser source for transportable atom-based quantum sensors that can be adapted to other sensors such as atomic clocks, accelerometers, gyroscopes or magnetometers with minor modifications.

Optics Express•Dec 22, 2022•18 citations

Construction of optical system for an atomic clock-beyond atomic fountain

王秀梅 Wang Xiumei, Jin He, Yifei Wang +18 more

We demonstrate the construction of the optical system in the atomic clock-beyond atomic fountain based on 87Rb atom. The optical system includes a high-stability laser system and an optical lattice. The high-stability laser system with the new scheme of frequency locking and shift is introduced in detail, which is an important laser source for laser cooling. The optimized frequency and intensity stability are achieved to 4 × 10–14 τ−1/2 ( τ is the averaging time) and 4 × 10–5 τ−1/2 , respectively, which are highly stable. On the basis of the conventional atomic fountain clock, the optical lattice is specially investigated along the direction of gravity and its characteristics are studied systematically. For the optimized and novel exploration, we predict the achievable stability of 3.6×10−14τ−1/2 and it has the potential to be improved to 3.6×10−15τ−1/2 . The realizability of the construction due to the stabilized laser and optical lattice makes the beyond fountain promising candidate for the next-generation high performance microwave atomic clock.

Frontiers in Physics•Aug 25, 2022•1 citation

A Simplified Laser and Optics System for Laser-Cooled RB Fountain Frequency Standards

Paul D. Kunz, Thomas P. Heavner, Steven R. Jefferts

We are developing a simple and robust laser and optics system suitable for a transportable laser-cooled rubidium (Rb) atomic fountain frequency standard. This system uses DFB (Distributed Feedback) diode lasers and a frequency offset-locking scheme to generate the optical frequencies needed for laser-cooling, launching, post-cooling, and detection of Rb atoms. Here, we describe the early results from this project and the anticipated performance of a compact, transportable Rb fountain frequency standard using this laser system. This system will also be useful for nontransportable laser-cooled atomic frequency standards.

•Nov 1, 2007•1 citation
Using modularized components, we have built a miniaturized optical system for 87 Rb atomic fountain clock that is fitted on an 80 cm × 60 cm optical breadboard. Compared with the conventional optical setup on the table, our system is more compact, more robust and miniaturized. Taking advantage of this system, laser beams are transmitted through eight optical fibre patch cords from the optical breadboard to an ultra high vacuum system. This optical setup has operated for five months in our fountain system and required no alignment.
In this Letter, we describe an optical assembly that is designed for the engineering application of the atomic laser cooling techniques.Using a folded optical path scheme, we have built a miniaturized, compact magneto-optical trap (CMOT) for an 87 Rb atomic fountain clock.Compared with the conventional magneto-optical traps used in other clocks, our system is more robust, more compact, more stable, and saves about 60% laser power.This optical setup has operated for about a year in our fountain system, passed the thermal cycle tests and the mechanical vibration and shock tests, and maintained a high performance without a need for realignment.
We report a transportable one-dimensional optical lattice clock based on 87Sr at the National Time Service Center. The transportable apparatus consists of a compact vacuum system and compact optical subsystems. The vacuum system with a size of 90 cm× 20 cm× 42 cm and the beam distributors are assembled on a double-layer optical breadboard. The modularized optical subsystems are integrated on independent optical breadboards. By using a 230 ms clock laser pulse, spin-polarized spectroscopy with a linewidth of 4.8 Hz is obtained which is close to the 3.9 Hz Fourier-limit linewidth. The time interleaved self-comparison frequency instability is determined to be 6.3 × 10–17 at an averaging time of 2000 s.
Nowadays, atom-based quantum sensors are leaving the laboratory towards field applications requiring compact and robust laser systems. Here we describe the realization of a compact laser system for atomic gravimetry. Starting with a single diode laser operating at 780 nm and adding only one fiber electro-optical modulator, one acousto-optical modulator and one laser amplifier we produce laser beams at all the frequencies required for a Rb-87 atomic gravimeter. Furthermore, we demonstrate that an atomic fountain configuration can also be implemented with our laser system. The modulated system reported here represents a substantial advance in the simplification of the laser source for transportable atom-based quantum sensors that can be adapted to other sensors such as atomic clocks, accelerometers, gyroscopes or magnetometers with minor modifications.
We demonstrate the construction of the optical system in the atomic clock-beyond atomic fountain based on 87Rb atom. The optical system includes a high-stability laser system and an optical lattice. The high-stability laser system with the new scheme of frequency locking and shift is introduced in detail, which is an important laser source for laser cooling. The optimized frequency and intensity stability are achieved to 4 × 10–14 τ−1/2 ( τ is the averaging time) and 4 × 10–5 τ−1/2 , respectively, which are highly stable. On the basis of the conventional atomic fountain clock, the optical lattice is specially investigated along the direction of gravity and its characteristics are studied systematically. For the optimized and novel exploration, we predict the achievable stability of 3.6×10−14τ−1/2 and it has the potential to be improved to 3.6×10−15τ−1/2 . The realizability of the construction due to the stabilized laser and optical lattice makes the beyond fountain promising candidate for the next-generation high performance microwave atomic clock.
We are developing a simple and robust laser and optics system suitable for a transportable laser-cooled rubidium (Rb) atomic fountain frequency standard. This system uses DFB (Distributed Feedback) diode lasers and a frequency offset-locking scheme to generate the optical frequencies needed for laser-cooling, launching, post-cooling, and detection of Rb atoms. Here, we describe the early results from this project and the anticipated performance of a compact, transportable Rb fountain frequency standard using this laser system. This system will also be useful for nontransportable laser-cooled atomic frequency standards.