Technical Physics Letters

Increase in critical current in a cross-shaped thin-film superconducting bridge in a microwave field

Iu. G. Bevza, V. I. Karamushko, I. M. Dmitrenko, Zach Griffith

Published Apr 1, 1976• 0 citations
OpenAlex

Abstract

The feasibility of a new, current controlled Josephson contact is demonstrated by observing weak coupling over a long superconducting bridge. (AIP)

Related papers

Observation of microwave Josephson radiation in thin-film superconducting bridges

V. N. Gubanov, V. P. Koshelets, G. A. Ovsyannikov

•Apr 1, 1975•13 citations

Superconducting noise bolometer with microwave bias and readout for array applications

Artem A. Kuzmin, Alexei D. Semenov, S. V. Shitov +4 more

We present a superconducting noise bolometer for terahertz radiation, which is suitable for large-format arrays. It is based on an antenna-coupled superconducting micro-bridge embedded in a high-quality factor superconducting resonator for a microwave bias and readout with frequency-division multiplexing in the GHz range. The micro-bridge is kept below its critical temperature and biased with a microwave current of slightly lower amplitude than the critical current of the micro-bridge. The response of the detector is the rate of superconducting fluctuations, which depends exponentially on the concentration of quasiparticles in the micro-bridge. Excess quasiparticles are generated by an incident THz signal. Since the quasiparticle lifetime increases exponentially at lower operation temperature, the noise equivalent power rapidly decreases. This approach allows for large arrays of noise bolometers operating above 1 K with sensitivity, limited by 300-K background noise. Moreover, the response of the bolometer always dominates the noise of the readout due to relatively large amplitude of the bias current. We performed a feasibility study on a proof-of-concept device with a 1.0 × 0.5 μm2 micro-bridge from a 9-nm thin Nb film on a sapphire substrate. Having a critical temperature of 5.8 K, it operates at 4.2 K and is biased at the frequency 5.6 GHz. For the quasioptical input at 0.65 THz, we measured the noise equivalent power ≈3 × 10−12 W/Hz1/2, which is close to expectations for this particular device in the noise-response regime.

arXiv:1709.02997•Applied Physics Letters•Jul 24, 2017•8 citations

Effect of Microwaves on Josephson Currents in Superconducting Tunneling

Sidney Shapiro, ANDRE R. JANUS, Sándor Holly

Reviews of Modern Physics•Jan 1, 1964•236 citations

ac Josephson effect in superconducting all-Nb thin-film nanobridges up to 693 GHz

Yoshinori Uzawa, Etsuo Kawate, Nobumitsu Hirose +5 more

All-niobium thin-film nanobridges were fabricated with bridge sizes of 40-nm length, 50-nm width, and 100-nm thickness. We investigated the performance of the nanobridges by monitoring Shapiro steps induced on the current-voltage curves by an optically pumped far-infrared laser. These steps have been observed up to 693 GHz (433 μm). This is a twofold increase over that previously reported on thin-film nanobridges.

Applied Physics Letters•Aug 24, 1992•3 citations

The effect of junction resistance on coupling between the microwave and the Josephson tunneling junction

F. S. Liu, Heng Wu

•May 1, 1978•0 citations

Gap enhancement in narrow superconducting tunneljunctions induced by homogeneous microwave currents

RT Horstman, Joachim H. Wolter

Physics Letters A•Mar 1, 1981•19 citations
We present a superconducting noise bolometer for terahertz radiation, which is suitable for large-format arrays. It is based on an antenna-coupled superconducting micro-bridge embedded in a high-quality factor superconducting resonator for a microwave bias and readout with frequency-division multiplexing in the GHz range. The micro-bridge is kept below its critical temperature and biased with a microwave current of slightly lower amplitude than the critical current of the micro-bridge. The response of the detector is the rate of superconducting fluctuations, which depends exponentially on the concentration of quasiparticles in the micro-bridge. Excess quasiparticles are generated by an incident THz signal. Since the quasiparticle lifetime increases exponentially at lower operation temperature, the noise equivalent power rapidly decreases. This approach allows for large arrays of noise bolometers operating above 1 K with sensitivity, limited by 300-K background noise. Moreover, the response of the bolometer always dominates the noise of the readout due to relatively large amplitude of the bias current. We performed a feasibility study on a proof-of-concept device with a 1.0 × 0.5 μm2 micro-bridge from a 9-nm thin Nb film on a sapphire substrate. Having a critical temperature of 5.8 K, it operates at 4.2 K and is biased at the frequency 5.6 GHz. For the quasioptical input at 0.65 THz, we measured the noise equivalent power ≈3 × 10−12 W/Hz1/2, which is close to expectations for this particular device in the noise-response regime.