Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Receiving-amplifying system with a superconducting bolometer

Н. А. Pankratov, Г. А. Зайцев, I. A. Khrebtov

Published Jan 1, 1972• 0 citations
OpenAlex

Related papers

Superconducting Hot Electron Bolometer Mixers for Submillimeter Receivers

Anders J. Skalare, William R. McGrath, Bruce Bumble +4 more

•May 10, 1994•0 citations

Frequency multiplexed superconducting quantum interference device readout of large bolometer arrays for cosmic microwave background measurements

M. Dobbs, Martin Lueker, K. A. Aird +44 more

A technological milestone for experiments employing transition edge sensor bolometers operating at sub-Kelvin temperature is the deployment of detector arrays with 100s-1000s of bolometers. One key technology for such arrays is readout multiplexing: the ability to read out many sensors simultaneously on the same set of wires. This paper describes a frequency-domain multiplexed readout system which has been developed for and deployed on the APEX-SZ and South Pole Telescope millimeter wavelength receivers. In this system, the detector array is divided into modules of seven detectors, and each bolometer within the module is biased with a unique ∼MHz sinusoidal carrier such that the individual bolometer signals are well separated in frequency space. The currents from all bolometers in a module are summed together and pre-amplified with superconducting quantum interference devices operating at 4 K. Room temperature electronics demodulate the carriers to recover the bolometer signals, which are digitized separately and stored to disk. This readout system contributes little noise relative to the detectors themselves, is remarkably insensitive to unwanted microphonic excitations, and provides a technology pathway to multiplexing larger numbers of sensors.

arXiv:1112.4215•Review of Scientific Instruments•Jul 1, 2012•163 citations

The design and instrumentation of a superconducting bolometer

Jerald Ray Hyde

•Jan 1, 2015•0 citations

SINIS Bolometer with Microwave Readout

Michael A. Tarasov, Sumedh Mahashabde, Aleksandra A. Gunbina +9 more

Abstract A bolometer, which is based on a superconductor–insulator–normal metal–insulator–superconductor (SINIS) structure, integrated into a twin-slot antenna with a central frequency of 90 GHz, and connected with a superconducting microwave readout resonator, has been designed, fabricated, and experimentally studied. Such an elementary cell is designed for the multi-element array of a high-sensitive radioastronomic receiver, in which the readout from a great number of channels is performed by a single coaxial cable instead of separate wires and amplifier in each channel.

Physics of the Solid State•Sep 1, 2020•6 citations

Fast-response superconducting electronic bolometer

Eugene M. Gershenzon, Murray Gershenzon, Gregory N Gol'tsman +2 more

Technical Physics Letters•Feb 1, 1989•1 citation

Superconducting bolometer current modulator

E.P. Vtorov, I. M. Dmitrenko

Cryogenics•Feb 1, 1967•3 citations
A technological milestone for experiments employing transition edge sensor bolometers operating at sub-Kelvin temperature is the deployment of detector arrays with 100s-1000s of bolometers. One key technology for such arrays is readout multiplexing: the ability to read out many sensors simultaneously on the same set of wires. This paper describes a frequency-domain multiplexed readout system which has been developed for and deployed on the APEX-SZ and South Pole Telescope millimeter wavelength receivers. In this system, the detector array is divided into modules of seven detectors, and each bolometer within the module is biased with a unique ∼MHz sinusoidal carrier such that the individual bolometer signals are well separated in frequency space. The currents from all bolometers in a module are summed together and pre-amplified with superconducting quantum interference devices operating at 4 K. Room temperature electronics demodulate the carriers to recover the bolometer signals, which are digitized separately and stored to disk. This readout system contributes little noise relative to the detectors themselves, is remarkably insensitive to unwanted microphonic excitations, and provides a technology pathway to multiplexing larger numbers of sensors.
Abstract A bolometer, which is based on a superconductor–insulator–normal metal–insulator–superconductor (SINIS) structure, integrated into a twin-slot antenna with a central frequency of 90 GHz, and connected with a superconducting microwave readout resonator, has been designed, fabricated, and experimentally studied. Such an elementary cell is designed for the multi-element array of a high-sensitive radioastronomic receiver, in which the readout from a great number of channels is performed by a single coaxial cable instead of separate wires and amplifier in each channel.