Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2611.17367

A trap-based platform for cooling and laser spectroscopy of fast ions toward radioactive-ion applications

Stefanos Pelonis, Tobias Christen, W. Gins, Bram Hendrickx, Phillip Imgram, Angelos Karadimas, Á. Koszorús, Sandro Krämer, Stef Kunnen, Pierre Lassegues, A. Raggio, Robbe Van Duyse, R. P. de Groote

Published Nov 6, 2026• 0 citations
arXivHTMLPDF

Abstract

We report on the first experiments with the Stopping and Trapping of Radioactive Isotopes for Precision Experiments (STRIPE) segmented linear Paul trap. The intent for this apparatus is to serve as an efficient capture and laser-cooling trap for radioactive isotopes produced at radioactive ion beam facilities. We demonstrate the deceleration of 10 keV ion beams and their trapping and laser cooling into Coulomb crystals. As an initial spectroscopic benchmark, the dipole-forbidden $5s$ $^2S_{1/2}$ $\rightarrow$ $4d$ $^2D_{5/2}$ transition in $^{88}$Sr$^+$ was driven, partially resolving the Zeeman structure and yielding a Gaussian linewidth of 14.5(8) MHz, with the residual width attributed to the ions' micromotion. The lifetime of the metastable $4d$ $^2D_{5/2}$ state was measured to be 0.325(5)$_{\mathrm{stat}}$(4)$_{\mathrm{sys}}$ s, uncorrected for collisional quenching. Several measurements to quantify the cooling timescale, the detection rate of the photon collection region and the trap storage lifetime were also performed. The developed technique will allow radioactive ion beams to be decelerated and cooled for precision spectroscopy measurements.

DOI
10.48550/arxiv.2611.17367

Related papers

Laser cooling and imaging of individual radioactive Sr+90 ions

Kyunghun Jung, Yoshihiro Iwata, Masabumi Miyabe +4 more

We have developed an apparatus integrating resonance-ionization, ion-trap, and laser-cooling techniques for an ultratrace radioactive isotope $^{90}\mathrm{Sr}$ analysis. Trapped $^{90}\mathrm{Sr}^{+}$ isotope ions were laser cooled, and their $4d\phantom{\rule{0.16em}{0ex}}^{2}D_{3/2}\ensuremath{\rightarrow}5p\phantom{\rule{0.16em}{0ex}}^{2}P_{1/2}$ transition isotope shift was experimentally measured to be $\ensuremath{-}281(17)$ MHz by comparing individual spectra of $^{88}\mathrm{Sr}^{+}$ and $^{90}\mathrm{Sr}^{+}$ ions. Crystallization of $^{90}\mathrm{Sr}^{+}$ was carried out using the resonance frequency value confirmed in our experiment, and then $^{90}\mathrm{Sr}^{+}$ individual ions were successfully observed.

Physical Review A•Oct 30, 2017•14 citations

Sympathetic cooling in a multi-isotope Sr+Coulomb crystal

S. Removille, Quentin Glorieux, T. Coudreau +3 more

This paper reports on trapping and laser-cooling of singly-ionized strontium ions in a linear Paul trap. We demonstrate loading of large ion clouds containing as much as 106 ions and laser cooling down to the Coulomb crystal transition. We observe the spatial segregation of the different Sr+ isotopes due to the mass-dependent Paul trap stiffness. Sympathetic cooling of the different isotopes is demonstrated, either by laser-cooling of 88Sr+ (83% abundance) or of 86Sr+ (10% abundance). These demonstrations open the way to the use of a large ion Coulomb crystal for quantum optics and quantum information experiments, where the strong confinement, the long lifetime, and the absence of perturbation by cooling lasers are crucial.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 30, 2010•2 citations

All-diode-laser cooling of Sr + isotope ions for analytical applications

Kyunghun Jung, Kazuhiro Yamamoto, Yuta Yamamoto +3 more

Trapping and cooling of Sr + isotope ions by an all-diode-laser system has been demonstrated in order to develop a novel mass spectrometric technique in combination with ion trap-laser cooling. First, we constructed external cavity diode lasers and associated stabilization apparatus for laser cooling of Sr + ions. The transition frequencies confirmed by optogalvanic spectroscopy enabled successful cooling of 88 Sr + ions. An image of two trapped ions has been captured by CCD camera. Minor isotopes, 84 Sr + and 86 Sr + , were also cooled and trapped. From an analysis of the observed spectra of a string crystal of each isotope, the isotope shifts of the cooling transition (5s 2 S 1/2 → 5p 2 P 1/2 ) of Sr + ions were determined to be +371(8) MHz for Δν 84–88 and +169(8) MHz for Δν 86–88 . In the case of the repumping transition (4d 2 D 3/2 → 5p 2 P 1/2 ), Δν 84–88 and Δν 86–88 were measured to be −833(6) and −400(5) MHz, respectively. These values are in good agreement with previously reported values.

Japanese Journal of Applied Physics•May 23, 2017•13 citations

Addressing and Cooling of Single Ions in Paul Traps

Hanns‐Christoph Nägerl, Christian F. Roos, H. J. Rohde +4 more

The use of cold trapped ions for quantum information processing requires the preparation of linear strings of ions at low temperatures and the coherent manipulation by laser light of the quantum state of individual ions in the string. In our experiment, 40Ca+ ions are trapped in a linear Paul trap, forming crystallized linear strings when laser cooled. These strings are observed by fluorescence detection on the S1/2-P1/2 dipole transition at 397 nm using a photomultiplier and a CCD camera. The narrow S1/2-D5/2 quadrupole transition at 729 nm is used to investigate and manipulate the vibrational motion of the ion in the trap. The spectral resolution obtained up to now on this transition is 2 · 10—12, proving long coherence time of the two-level system. Addressing of individual ions in the string is achieved, using a tightly focused laser beam at 729 nm, and detected by the observation of quantum jumps from the S1/2 to the D5/2 level. These experimental techniques make ions in a superposition of their S1/2 and D5/2 states suitable as qubits for quantum information processing. The realization of a two-ion quantum gate furthermore requires ground-state cooling of the string. The status of current experiments is reviewed and techniques to achieve ground-state cooling of ion strings are discussed.

Fortschritte der Physik•May 1, 2000•25 citations

Stabilization and control in a linear ion trap

J.-P. Stacey

This thesis describes experimental work towards developing a trapped ion quantum information processor. An existing ion trap apparatus was capable of trapping and laser-cooling single ions or small ion strings of 40 Ca+, and had been used for studies of quantum jumps and natural lifetime measurements in Ca. This thesis describes improvements in this apparatus, which have allowed the stability and the flexibility of experimental control of the ions to be greatly increased. This enabled experiments to read out the spin state of a single trapped ion, and to load ions with isotope selectivity through photoionization. The optical systems were improved by installation of new lasers, optical reference cavities, and a system of acousto-optic modulators for laser intensity switching and frequency control. The photon counting for fluorescence detection was improved, and a new photon time-of-arrival correlation circuit developed. This has permitted rapid and more sensitive detection of micromotion, and hence cancellation of stray fields in the trap. A study of resonant circuits in the low RF, high voltage (10 MHz, 1 kV) regime was carried out with a view to developing a new RF supply for the Paul trap with reduced noise and increased power. A new supply based on a helical resonator was built and used to trap ions. This technique has reduced noise and will permit higher secular frequencies to be attained in the future. A magnetic field B in the ion trap is used to define a quantization axis, and in one series of experiments was required to be of order 100 G to provide a substantial Zeeman splitting. A set of magnetic field coils to control the size and direction of B is described. The design of these posed some problems owing to an unforseen issue with the vacuum chamber. In short, it is magnetizable and acts to first approximation like a magnetic shield. The field coils had to be sufficiently substantial to produce the desired field at the ion even in the presence of this shielding effect, and dark resonance (and other) spectra with Zeeman splitting were obtained to calibrate the field using the ion as a probe. Finally, the thesis describes the successful loading of the ion trap by laser photoionization from a weak atomic beam. This involved two new lasers at 423 nm and 389 nm. Saturated absorption spectroscopy of neutral calcium is first described, then transverse excitation of an atomic beam in our vacuum chamber is used to identify all the main isotopes of calcium and confirm their abundances in our source (a heated sample of natural calcium). Finally, photoionization is used to load the trap. This has three advantages over electron-impact ionization. By avoiding an electron gun, we avoid charging of insulating patches and subsequent electric field drift as they discharge; the flux in the atomic beam and hence calcium (and other) deposits on the electrodes can be greatly reduced; and most importantly, the photoionization is isotope selective. Evidence is presented which suggests that even with an non-enriched source, the rare isotope 43 Ca can be loaded with reasonable efficiency. This isotope is advantageous for quantum information experiments for several reasons, but chiefly because its ground state hyperfine structure can act as a stable qubit.

•Jan 1, 2003•8 citations

Coulomb crystals in a cryogenic Paul trap for sympathetic cooling of molecular ions and highly charged ions

A. Windberger, M. Schwarz, Oscar O. Versolato +11 more

Electron beam ion traps used for spectroscopy of highly charged ions (HCI) produce a deep trapping potential leading to high temperatures of the stored ions, and thus limiting the achievable spectral resolution. A novel device at the Max-Planck-Institut für Kernphysik, the Cryogenic linear Paul Trap Experiment (CryPTEx), attached to an electron beam ion trap, provides a new experimental platform to overcome these limitations. The trap assembly operates at a temperature of 4 K and offers optical access for quantum manipulation and imaging of the trapped ions. Since forbidden optical transitions in HCI do not support direct laser cooling, sympathetic cooling with Coulomb crystals of singly charged ions such as Be+ or Mg+ will be applied in order to reach the natural linewidth of optical forbidden transitions in HCI of interest. With the added advantage of long ion trapping times resulting from residual gas pressures of H2 at 4 K below 10−15 mbar, CryPTEx has been commissioned in collaboration with the Ion Trap Group in Århus using rovibrationally cooled MgH+ ions. Strong suppression of the black body radiation at the trap center, ion storage times of about 28 hours, and largely enhanced population of the rovibrational ground state were achieved.

AIP conference proceedings•Jan 1, 2013•5 citations
We report on the first experiments with the Stopping and Trapping of Radioactive Isotopes for Precision Experiments (STRIPE) segmented linear Paul trap. The intent for this apparatus is to serve as an efficient capture and laser-cooling trap for radioactive isotopes produced at radioactive ion beam facilities. We demonstrate the deceleration of 10 keV ion beams and their trapping and laser cooling into Coulomb crystals. As an initial spectroscopic benchmark, the dipole-forbidden 5s5s5s 2S1/2^2S_{1/2}2S1/2​ →\rightarrow→ 4d4d4d 2D5/2^2D_{5/2}2D5/2​ transition in 88^{88}88Sr+^++ was driven, partially resolving the Zeeman structure and yielding a Gaussian linewidth of 14.5(8) MHz, with the residual width attributed to the ions' micromotion. The lifetime of the metastable 4d4d4d 2D5/2^2D_{5/2}2D5/2​ state was measured to be 0.325(5)stat_{\mathrm{stat}}stat​(4)sys_{\mathrm{sys}}sys​ s, uncorrected for collisional quenching. Several measurements to quantify the cooling timescale, the detection rate of the photon collection region and the trap storage lifetime were also performed. The developed technique will allow radioactive ion beams to be decelerated and cooled for precision spectroscopy measurements.
We have developed an apparatus integrating resonance-ionization, ion-trap, and laser-cooling techniques for an ultratrace radioactive isotope 90Sr^{90}\mathrm{Sr}90Sr analysis. Trapped 90Sr+^{90}\mathrm{Sr}^{+}90Sr+ isotope ions were laser cooled, and their $4d\phantom{\rule{0.16em}{0ex}}^{2}D_{3/2}\ensuremath{\rightarrow}5p\phantom{\rule{0.16em}{0ex}}^{2}P_{1/2}$ transition isotope shift was experimentally measured to be $\ensuremath{-}281(17)$ MHz by comparing individual spectra of 88Sr+^{88}\mathrm{Sr}^{+}88Sr+ and 90Sr+^{90}\mathrm{Sr}^{+}90Sr+ ions. Crystallization of 90Sr+^{90}\mathrm{Sr}^{+}90Sr+ was carried out using the resonance frequency value confirmed in our experiment, and then 90Sr+^{90}\mathrm{Sr}^{+}90Sr+ individual ions were successfully observed.
This paper reports on trapping and laser-cooling of singly-ionized strontium ions in a linear Paul trap. We demonstrate loading of large ion clouds containing as much as 106 ions and laser cooling down to the Coulomb crystal transition. We observe the spatial segregation of the different Sr+ isotopes due to the mass-dependent Paul trap stiffness. Sympathetic cooling of the different isotopes is demonstrated, either by laser-cooling of 88Sr+ (83% abundance) or of 86Sr+ (10% abundance). These demonstrations open the way to the use of a large ion Coulomb crystal for quantum optics and quantum information experiments, where the strong confinement, the long lifetime, and the absence of perturbation by cooling lasers are crucial.
Trapping and cooling of Sr + isotope ions by an all-diode-laser system has been demonstrated in order to develop a novel mass spectrometric technique in combination with ion trap-laser cooling. First, we constructed external cavity diode lasers and associated stabilization apparatus for laser cooling of Sr + ions. The transition frequencies confirmed by optogalvanic spectroscopy enabled successful cooling of 88 Sr + ions. An image of two trapped ions has been captured by CCD camera. Minor isotopes, 84 Sr + and 86 Sr + , were also cooled and trapped. From an analysis of the observed spectra of a string crystal of each isotope, the isotope shifts of the cooling transition (5s 2 S 1/2 → 5p 2 P 1/2 ) of Sr + ions were determined to be +371(8) MHz for Δν 84–88 and +169(8) MHz for Δν 86–88 . In the case of the repumping transition (4d 2 D 3/2 → 5p 2 P 1/2 ), Δν 84–88 and Δν 86–88 were measured to be −833(6) and −400(5) MHz, respectively. These values are in good agreement with previously reported values.
The use of cold trapped ions for quantum information processing requires the preparation of linear strings of ions at low temperatures and the coherent manipulation by laser light of the quantum state of individual ions in the string. In our experiment, 40Ca+ ions are trapped in a linear Paul trap, forming crystallized linear strings when laser cooled. These strings are observed by fluorescence detection on the S1/2-P1/2 dipole transition at 397 nm using a photomultiplier and a CCD camera. The narrow S1/2-D5/2 quadrupole transition at 729 nm is used to investigate and manipulate the vibrational motion of the ion in the trap. The spectral resolution obtained up to now on this transition is 2 · 10—12, proving long coherence time of the two-level system. Addressing of individual ions in the string is achieved, using a tightly focused laser beam at 729 nm, and detected by the observation of quantum jumps from the S1/2 to the D5/2 level. These experimental techniques make ions in a superposition of their S1/2 and D5/2 states suitable as qubits for quantum information processing. The realization of a two-ion quantum gate furthermore requires ground-state cooling of the string. The status of current experiments is reviewed and techniques to achieve ground-state cooling of ion strings are discussed.
This thesis describes experimental work towards developing a trapped ion quantum information processor. An existing ion trap apparatus was capable of trapping and laser-cooling single ions or small ion strings of 40 Ca+, and had been used for studies of quantum jumps and natural lifetime measurements in Ca. This thesis describes improvements in this apparatus, which have allowed the stability and the flexibility of experimental control of the ions to be greatly increased. This enabled experiments to read out the spin state of a single trapped ion, and to load ions with isotope selectivity through photoionization. The optical systems were improved by installation of new lasers, optical reference cavities, and a system of acousto-optic modulators for laser intensity switching and frequency control. The photon counting for fluorescence detection was improved, and a new photon time-of-arrival correlation circuit developed. This has permitted rapid and more sensitive detection of micromotion, and hence cancellation of stray fields in the trap. A study of resonant circuits in the low RF, high voltage (10 MHz, 1 kV) regime was carried out with a view to developing a new RF supply for the Paul trap with reduced noise and increased power. A new supply based on a helical resonator was built and used to trap ions. This technique has reduced noise and will permit higher secular frequencies to be attained in the future. A magnetic field B in the ion trap is used to define a quantization axis, and in one series of experiments was required to be of order 100 G to provide a substantial Zeeman splitting. A set of magnetic field coils to control the size and direction of B is described. The design of these posed some problems owing to an unforseen issue with the vacuum chamber. In short, it is magnetizable and acts to first approximation like a magnetic shield. The field coils had to be sufficiently substantial to produce the desired field at the ion even in the presence of this shielding effect, and dark resonance (and other) spectra with Zeeman splitting were obtained to calibrate the field using the ion as a probe. Finally, the thesis describes the successful loading of the ion trap by laser photoionization from a weak atomic beam. This involved two new lasers at 423 nm and 389 nm. Saturated absorption spectroscopy of neutral calcium is first described, then transverse excitation of an atomic beam in our vacuum chamber is used to identify all the main isotopes of calcium and confirm their abundances in our source (a heated sample of natural calcium). Finally, photoionization is used to load the trap. This has three advantages over electron-impact ionization. By avoiding an electron gun, we avoid charging of insulating patches and subsequent electric field drift as they discharge; the flux in the atomic beam and hence calcium (and other) deposits on the electrodes can be greatly reduced; and most importantly, the photoionization is isotope selective. Evidence is presented which suggests that even with an non-enriched source, the rare isotope 43 Ca can be loaded with reasonable efficiency. This isotope is advantageous for quantum information experiments for several reasons, but chiefly because its ground state hyperfine structure can act as a stable qubit.
Electron beam ion traps used for spectroscopy of highly charged ions (HCI) produce a deep trapping potential leading to high temperatures of the stored ions, and thus limiting the achievable spectral resolution. A novel device at the Max-Planck-Institut für Kernphysik, the Cryogenic linear Paul Trap Experiment (CryPTEx), attached to an electron beam ion trap, provides a new experimental platform to overcome these limitations. The trap assembly operates at a temperature of 4 K and offers optical access for quantum manipulation and imaging of the trapped ions. Since forbidden optical transitions in HCI do not support direct laser cooling, sympathetic cooling with Coulomb crystals of singly charged ions such as Be+ or Mg+ will be applied in order to reach the natural linewidth of optical forbidden transitions in HCI of interest. With the added advantage of long ion trapping times resulting from residual gas pressures of H2 at 4 K below 10−15 mbar, CryPTEx has been commissioned in collaboration with the Ion Trap Group in Århus using rovibrationally cooled MgH+ ions. Strong suppression of the black body radiation at the trap center, ion storage times of about 28 hours, and largely enhanced population of the rovibrational ground state were achieved.