arXiv:2611.15757
Buffer-Gas-Assisted Fluorescence Spectroscopy of Molecular Ions
Jinyue Jiang, Kenji Shu, Huaxu Dan, Xing Fan
Abstract
Sustained fluorescence detection of generic molecules has been challenging due to the lack of cycling transitions and limited photon budgets. We demonstrate a nondestructive method for continuous fluorescence of strongly rovibronically open molecular ions, $^{232}$ThF$^+$. Effective quasi-cycling transitions are established by room-temperature buffer-gas collisions, which replenish the population back to the laser-addressed states. In situ images and rotationally resolved spectra are obtained without optical repumping or auxiliary atomic readout ions. Combined with low-background spectroscopic detection, this approach achieves a signal-to-noise ratio of approximately 6 in a 1 s exposure on the P(1) line of $^{232}$ThF$^+$, despite a thermal population of only approximately 0.17% in the addressed state at room temperature. The ability to repeatedly interrogate trapped ions is particularly promising for scarce molecular samples, broadband spectroscopic searches, and in situ monitoring of molecular reactions.
AI Summary
Fluorescence spectroscopy of molecular ions is limited by decay into unaddressed rovibrational and electronic states. This paper tests whether buffer-gas collisions can recycle that population, enabling repeated interrogation without optical repumping or auxiliary atomic ions. The experiment traps $10^4$–$10^5$ $^{232}\mathrm{ThF}^{+}$ ions at room temperature, excites a rotationally resolved transition near 685 nm, and images red-shifted fluorescence near 718 nm. Argon pressures up to 330 mPa provide population redistribution. Closing the gas valve suppresses fluorescence while trapped ions remain detectable by time-of-flight; reopening it restores fluorescence without reloading. These observations support collision-assisted population recycling. Typical resonant signals reach approximately $1.5\times10^3$ photoelectrons/s. The reported signal-to-noise ratio on $P(1)$ is approximately 6 for a 1 s exposure, despite an addressed-state thermal population of about 0.17%. Frequency scans reuse each ensemble for approximately 20 s. A 100 GHz survey identifies 24 assigned transitions and seven unassigned features. A rotational-Hamiltonian fit to 30 assigned lines extending to $J''=51$ has a 14.1 MHz residual RMS. A simplified population-rate model gives a rotational temperature of $385(55)$ K and, assuming an excitation rate, estimates dark-state return rates of $10$–$100\,\mathrm{s}^{-1}$. Applicability requires an accessible optical transition and sufficiently efficient dark-state return. The rate model simplifies multiple dark states and does not directly measure individual quenching channels. Residual-gas reactions limit fluorescence lifetimes to roughly 20 s, and pressure-dependent extraction losses complicate ion-number diagnostics.
Error found: The abstract's P(1) SNR of approximately 6 in 1 s cannot be independently reproduced from the signal and noise information provided. The fluorescence model conflates total dark-state branching with detected-band branching, giving an incorrect general expression for detected fluorescence flux. The observed pressure saturation does not by itself identify an Ar-independent quenching bottleneck, because the stated model also predicts saturation for a return rate proportional to Ar pressure.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 7 pages, 4 figures