arXiv:2611.03343
Quartet state of the neutral nitrogen-vacancy center in diamond and optimized spin readout under near-infrared two-photon excitation
Nikoletta Jegenyes, Pál Maák, Vladimir Verkhovlyuk, László Himics, Tamás Váczi, Miklós Veres, Ádám Gali
Abstract
Photoionization of the excited nitrogen-vacancy center (NV-) in diamond leaves the neutral defect in a metastable quartet state of unknown energy. Using two-photon optically detected magnetic resonance with a tunable femtosecond laser, we resolve its onset in the spin contrast at 1.23 +/- 0.02 eV and, with the ground-state threshold from the same setup, place the quartet 0.54 +/- 0.04 eV above the neutral ground state. The threshold sets the optimum excitation for spin readout at 1060-1075 nm, in the near-infrared tissue window, with 26-37% higher shot-noise-limited sensitivity than at 1030-1040 nm.
AI Summary
The paper addresses the uncertain energy of the metastable quartet state of neutral nitrogen–vacancy centers and how photoionization channels limit near-infrared two-photon spin readout. It measures wavelength- and power-dependent photoluminescence and ODMR contrast in a room-temperature diamond ensemble using an 80 MHz tunable femtosecond laser. Comparing contrast at equal photoluminescence separates wavelength-dependent losses from brightness-dependent changes. A ten-level charge-and-spin rate model fitted to 52 contrast-loss measurements places the excited-state ionization threshold into the neutral quartet at $E_q=1.23\pm0.02$ eV. A separate low-power scan gives the negative-center ground-state ionization threshold as $2.63\pm0.03$ eV. Combining these thresholds with the 1.945 eV optical zero-phonon energy places the quartet $0.54\pm0.04$ eV above the neutral ground state. Long-wavelength contrast losses additionally require ionization into the neutral ground state, with an inferred cross section of $(1.3–2.3)\times10^{-19}$ cm$^2$. The measured shot-noise readout figure of merit, $C\sqrt{S}$, peaks at 1060–1075 nm: at 300 mW it exceeds the values at 1040 and 1030 nm by 26% and 37%, respectively, despite lower raw contrast. These gains imply acquisition-time reductions of roughly 1.6–1.9 under shot-noise-limited conditions. The quartet energy is inferred through model-dependent threshold fits rather than direct spectroscopy. Its uncertainty incorporates variations in broadening, channel-strength ratios and the ground-state threshold. Singlet ionization and recharge processes produce no separately resolved signature within the 1.5% contrast-loss uncertainty and are omitted from the reported fits. Biological-media applications are proposed rather than demonstrated.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 6 pages, 4 figures; Supplemental Material (19 pages) appended. Data and code: doi:10.5158/ARP/T7NV6O