arXiv:2610.41270
Parametric Enhancement of an Optical Spring in a Dark Signal-Recycling Cavity
Kaido Suzuki, Ryo Iden, Ken-ichi Harada, Kentaro Somiya
Abstract
Optical springs tailor the response of precision sensors. Parametric amplification of the signal field stiffens the spring, extending the precision to higher frequencies. A Michelson interferometer operated at a dark fringe is the most direct way to separate the signal from the carrier for amplification. We experimentally demonstrate such quantum manipulation of the optical spring by placing an optical parametric amplifier in a cavity at the dark port, showing a significant increase of the optical-spring constant with the parametric gain within a factor of four below the oscillation threshold.
AI Summary
The paper asks whether intracavity parametric amplification can strengthen an interferometer’s optical spring without increasing circulating carrier power or exposing the nonlinear medium to that carrier. It implements an optical parametric amplifier (OPA) in the detuned signal-recycling cavity of a dark-fringe Michelson interferometer, where differential signal sidebands are separated from the carrier. The experiment uses a 1064-nm carrier with $300\,\mathrm{mW}$ per arm, a suspended 200-mg mirror, and a 532-nm pump. Auxiliary fields control the interferometer, cavity detuning, and amplification phase. Optical-spring frequencies are extracted from complex control-loop transfer functions measured under broadband excitation. Fitting their squared values versus detuning gives a peak spring-constant increase of $8.2\pm2.8\%$ and an inferred OPA amplitude gain $s=1.047\pm0.012$. A direct comparison of the largest measured spring constants gives $7.1\pm4.0\%$, without the detuning model but using the same data. The main stated systematic limitation is a pump-induced shift of the carrier resonance relative to the auxiliary field used for cavity control. Detuning therefore requires a phenomenological model, including a buildup-dependent shift. The fitted effective amplitude reflectivity is $0.834\pm0.012$, corresponding to approximately 14% single-pass power loss. The achieved gain is about four times below the zero-detuning oscillation threshold when expressed in decibels; further enhancement requires reduced loss or increased pump power. Lossless input–output calculations illustrate possible sensitivity improvements, but the experiment measures the optomechanical response rather than quantum-noise-limited sensitivity.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.