Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Parametric-amplification-enhanced Gaussian quantum metrology in non-Markovian environments

Jia-Xin Peng, Wei Li, Zhucheng Zhang, Chengsong Zhao, Zhong-Wei Yu, Chunfeng Wu, Zhe Sun

Published Nov 17, 2026• 0 citations
Publisher

Abstract

We study the quantum estimation of the optomechanical coupling strength in a cavity optomechanical system that includes a parametric amplifier and is coupled to a structured mechanical reservoir. We show that parametric amplification, together with non-Markovian effects, yields a significant enhancement of the estimation precision, which is directly linked to the spectral properties of the bath. We find that parametric amplification increases the difference between the estimation precision in non-Markovian and Markovian environments by amplifying the steady-state shift induced by the initial information backflow, a previously unidentified effect. The ultimate precision bound can be nearly saturated by a joint Homodyne measurement of the cavity’s amplitude quadrature and the mechanical oscillator’s position. We also treat the total sensing time as a resource and analyze the information acquisition rate. This analysis shows that the metrological advantage of non-Markovian effects over the corresponding Markovian case remains when time is taken into account as a resource and is further enhanced by increasing the parametric gain. Our results establish a direct connection between non-Markovian reservoir engineering and quantum metrology in optomechanical systems.

DOI
10.1103/z1h6-1shn

Related papers

Amplification of Weak Forces via Parametric Interactions and Non-Markovian Effects in Cavity Optomechanics

Y. F. Li, Ze Wang, W. Y. Hu +3 more

Weak force amplification describes the process of amplifying a faint low-frequency signal by means of an additional high-frequency modulation, which plays a vital role in quantum sensing and high-precision measurement. However, the potential enhancement of weak-force amplification in non-Markovian environments has received little attention. In this paper, we firstly study the amplification of weak forces within cavity-optomechanical systems incorporating a degenerate optical parametric amplifier (DOPA) under the Markovian assumption. The results show that the weak force can be effectively amplified by using two high-frequency signals via vibrational resonance through adjusting the strength and phase of the DOPA with different pumping frequencies. Moreover, we extend the study of the amplification of the weak force to the non-Markovian environment which consists of a collection of infinite oscillators. We illustrate that the amplification exhibits a conversion from the non-Markovian regime to Markovian regime by controlling environmental spectral width. This conversion leads to enhancements of amplification, which originates from the excitation backflow obtained through the interaction between the cavity and non-Markovian environment. By controlling DOPA to amplify weak forces, the study achieves amplification in the non-Markovian regime, offering new directions for quantum optics research.

arXiv:2605.17810•May 18, 2026•2 citations

Squeezed light and coherent feedback enhanced multiparameter quantum estimation in a double-cavity optomechanics: steady and dynamical states

Hamza Harraf, Mohamed Amazioug, Amjad Sohail +2 more

Multiparameter quantum estimation in open optomechanical systems is fundamentally constrained by dissipation, thermal fluctuations, and measurement incompatibility. In this work, we investigate a coupled cavity optomechanical platform in which two mechanical modes interact with driven optical cavities, two mode squeezed vacuum, intracavity degenerate parametric amplification, and coherent optical feedback. Using the continuous variable Gaussian state formalism, we derive the linearized quantum Langevin dynamics and steady state covariance matrix and evaluate the quantum Fisher information matrices associated with simultaneous estimation of the optomechanical coupling strength and cavity dissipation rate. We characterize the precision bounds using the symmetric and right logarithmic derivative formalisms and employ $\mathcal{B}_{\rm MI}=\max\{\mathcal{B}_S,\mathcal{B}_R\}$ as a comparative figure of merit within the SLD/RLD framework. We find that parametric amplification can substantially reduce the most informative bound, $\mathcal{B}_{\rm MI}$, thereby enhancing multiparameter estimation precision over a broad range of operating conditions. Coherent feedback can further reduce $\mathcal{B}_{\rm MI}$ and improve the estimation precision, particularly in the strong feedback regime. Moreover, the simultaneous presence of coherent feedback, parametric amplification, and squeezed light injection provides a combined mechanism for controlling quantum fluctuations and parameter dependent correlations, leading to enhanced and more robust multiparameter estimation. We further analyze the dynamical and steady state regimes to identify the parameter regions in which these quantum resources provide the largest metrological gain. Our results establish coupled cavity optomechanics as a flexible platform for quantum-noise engineering in multiparameter sensing.

quant-pharXiv:2609.05402•Sep 7, 2026•0 citations

Optomechanically controlled response amplification for enhanced quantum sensing

Javid Naikoo

We show that strongly amplified dynamical responses in cavity optomechanical systems can be harnessed for enhanced quantum sensing. By tuning the optomechanical interaction to a regime of enhanced susceptibility, weak perturbations produce disproportionately large changes in the system response, leading to substantially improved estimation precision. Using Gaussian estimation theory, we demonstrate that the quantum Fisher information exhibits a divergent scaling as the perturbation strength decreases, implying a corresponding suppression of the estimation error. We further show that heterodyne detection of the output cavity field yields the classical Fisher information with the same asymptotic scaling as the quantum Fisher information, demonstrating that the enhanced sensitivity is accessible with a standard measurement protocol. These results identify amplified optomechanical dynamics as a controllable resource for quantum enhanced sensing and metrology.

quant-pharXiv:2606.09716•Jun 9, 2026•0 citations

Quantum metrology of a structured reservoir

Youssef Aiache, Asghar Ullah, Özgür Esat Müstecaplıoğlu +1 more

Accurately characterizing the properties of structured reservoirs is a key challenge in quantum systems and is of great importance for advances in quantum metrology and sensing. In this work, we employ a two-level system (qubit) as a probe, which is coupled to a structured reservoir consisting of an ancilla qubit and a Markovian environment modeled as a thermal bath. By exploiting non-Markovian dynamics, we systematically investigate the effectiveness of different interaction types between the probe and ancilla for estimating critical parameters, including temperature, ancilla frequency, and system-bath coupling strength. We quantify the precision of parameter estimation using quantum Fisher information (QFI) and analyze the system dynamics in both transient and steady-state regimes. Our findings demonstrate that non-Markovianity substantially enhances parameter estimation in the transient regime, with specific interactions facilitating sustained information backflow and yielding higher QFI values. However, the performance of these interactions is contingent on the parameter under estimation and the operational regime. For instance, certain interactions become prominent in the transient regime but exhibit diminished utility in the steady state, whereas others maintain their effectiveness even at equilibrium. These results stress the importance of judiciously selecting interactions adapted to specific estimation objectives and operational regimes.

arXiv:2503.16261•Physical Review A•Jun 18, 2025•7 citations

Controlling multiparameter quantum estimation in exciton-optomechanics system

Hamza Harraf, Mohamed Amazioug, Rachid Ahl Laamara

Multiparameter quantum estimation has emerged as a central task in quantum metrology. In this work, we investigate multiparameter quantum estimation in a hybrid exciton--optomechanical (EOM) system. The system consists of a semiconductor quantum well embedded inside a driven optomechanical microcavity, where the excitonic, optical, and mechanical modes interact coherently through exciton--photon and radiation-pressure couplings. Using the Gaussian-state formalism, we derive the covariance matrix of the steady-state quantum fluctuations and employ both the symmetric logarithmic derivative (SLD) and right logarithmic derivative (RLD) approaches to evaluate the quantum Fisher information matrix associated with the simultaneous estimation of the exciton--photon coupling strength $g$ and the excitonic decay rate $k_x$. We analyze the corresponding quantum Cramér--Rao bounds and determine the most informative precision limit governing the attainable estimation accuracy. The influence of several experimentally relevant parameters, including temperature, driving power, optomechanical coupling strength, and dissipation rates, is investigated in detail. Our results show that strong hybrid interactions and low-temperature regimes significantly enhance the estimation precision, whereas thermal fluctuations and dissipation processes deteriorate the metrological performance. Furthermore, we compare the ultimate quantum limits with experimentally feasible Gaussian measurement strategies based on homodyne and heterodyne detection. We show that heterodyne detection provides better estimation performance than homodyne schemes and can approach the optimal quantum precision limit in suitable parameter regimes.

quant-pharXiv:2606.08949•Jun 9, 2026•2 citations

Enhancement of quantum estimation in cavity magnonics

Abderrahim Lakhfif, Abdallah Slaoui, Abdelkader Hidki +2 more

Quantum metrology enables measurement sensitivities beyond classical limits by exploiting quantum resources. Among promising platforms, hybrid cavity–magnon systems—where microwave photons interact with collective spin excitations in magnetic materials—offer a versatile testbed for emerging quantum technologies. However, their performance hinges on precise knowledge of the cavity–magnon coupling strength. Here, we propose an experimentally feasible scheme to enhance the quantum estimation of this parameter by leveraging coherent feedback and parametric amplification. Using the Heisenberg–Langevin formalism, we linearize the system dynamics and compute both quantum (QFI) and classical Fisher information. Our analysis shows that optimal detuning, strong driving, and cryogenic temperatures below 0.1 K significantly improve estimation precision, while magnon dissipation and thermal noise degrade the QFI. Parametric amplification enhances precision when the gain and phase are optimally tuned, and coherent feedback yields even greater sensitivity at tailored phase shifts and reflectivities. Notably, their combination achieves the lowest estimation error and the highest robustness against thermal noise. Finally, we identify the cavity mode as the optimal probe, with homodyne detection nearly saturating the quantum limit under ideal conditions. These findings establish a robust pathway for high-precision, noise-resilient cavity–magnon coupling estimation.

Journal of Physics A Mathematical and Theoretical•Jan 23, 2026•2 citations
We study the quantum estimation of the optomechanical coupling strength in a cavity optomechanical system that includes a parametric amplifier and is coupled to a structured mechanical reservoir. We show that parametric amplification, together with non-Markovian effects, yields a significant enhancement of the estimation precision, which is directly linked to the spectral properties of the bath. We find that parametric amplification increases the difference between the estimation precision in non-Markovian and Markovian environments by amplifying the steady-state shift induced by the initial information backflow, a previously unidentified effect. The ultimate precision bound can be nearly saturated by a joint Homodyne measurement of the cavity’s amplitude quadrature and the mechanical oscillator’s position. We also treat the total sensing time as a resource and analyze the information acquisition rate. This analysis shows that the metrological advantage of non-Markovian effects over the corresponding Markovian case remains when time is taken into account as a resource and is further enhanced by increasing the parametric gain. Our results establish a direct connection between non-Markovian reservoir engineering and quantum metrology in optomechanical systems.
Weak force amplification describes the process of amplifying a faint low-frequency signal by means of an additional high-frequency modulation, which plays a vital role in quantum sensing and high-precision measurement. However, the potential enhancement of weak-force amplification in non-Markovian environments has received little attention. In this paper, we firstly study the amplification of weak forces within cavity-optomechanical systems incorporating a degenerate optical parametric amplifier (DOPA) under the Markovian assumption. The results show that the weak force can be effectively amplified by using two high-frequency signals via vibrational resonance through adjusting the strength and phase of the DOPA with different pumping frequencies. Moreover, we extend the study of the amplification of the weak force to the non-Markovian environment which consists of a collection of infinite oscillators. We illustrate that the amplification exhibits a conversion from the non-Markovian regime to Markovian regime by controlling environmental spectral width. This conversion leads to enhancements of amplification, which originates from the excitation backflow obtained through the interaction between the cavity and non-Markovian environment. By controlling DOPA to amplify weak forces, the study achieves amplification in the non-Markovian regime, offering new directions for quantum optics research.
Multiparameter quantum estimation in open optomechanical systems is fundamentally constrained by dissipation, thermal fluctuations, and measurement incompatibility. In this work, we investigate a coupled cavity optomechanical platform in which two mechanical modes interact with driven optical cavities, two mode squeezed vacuum, intracavity degenerate parametric amplification, and coherent optical feedback. Using the continuous variable Gaussian state formalism, we derive the linearized quantum Langevin dynamics and steady state covariance matrix and evaluate the quantum Fisher information matrices associated with simultaneous estimation of the optomechanical coupling strength and cavity dissipation rate. We characterize the precision bounds using the symmetric and right logarithmic derivative formalisms and employ BMI=max⁡{BS,BR}\mathcal{B}_{\rm MI}=\max\{\mathcal{B}_S,\mathcal{B}_R\}BMI​=max{BS​,BR​} as a comparative figure of merit within the SLD/RLD framework. We find that parametric amplification can substantially reduce the most informative bound, BMI\mathcal{B}_{\rm MI}BMI​, thereby enhancing multiparameter estimation precision over a broad range of operating conditions. Coherent feedback can further reduce BMI\mathcal{B}_{\rm MI}BMI​ and improve the estimation precision, particularly in the strong feedback regime. Moreover, the simultaneous presence of coherent feedback, parametric amplification, and squeezed light injection provides a combined mechanism for controlling quantum fluctuations and parameter dependent correlations, leading to enhanced and more robust multiparameter estimation. We further analyze the dynamical and steady state regimes to identify the parameter regions in which these quantum resources provide the largest metrological gain. Our results establish coupled cavity optomechanics as a flexible platform for quantum-noise engineering in multiparameter sensing.
We show that strongly amplified dynamical responses in cavity optomechanical systems can be harnessed for enhanced quantum sensing. By tuning the optomechanical interaction to a regime of enhanced susceptibility, weak perturbations produce disproportionately large changes in the system response, leading to substantially improved estimation precision. Using Gaussian estimation theory, we demonstrate that the quantum Fisher information exhibits a divergent scaling as the perturbation strength decreases, implying a corresponding suppression of the estimation error. We further show that heterodyne detection of the output cavity field yields the classical Fisher information with the same asymptotic scaling as the quantum Fisher information, demonstrating that the enhanced sensitivity is accessible with a standard measurement protocol. These results identify amplified optomechanical dynamics as a controllable resource for quantum enhanced sensing and metrology.
Accurately characterizing the properties of structured reservoirs is a key challenge in quantum systems and is of great importance for advances in quantum metrology and sensing. In this work, we employ a two-level system (qubit) as a probe, which is coupled to a structured reservoir consisting of an ancilla qubit and a Markovian environment modeled as a thermal bath. By exploiting non-Markovian dynamics, we systematically investigate the effectiveness of different interaction types between the probe and ancilla for estimating critical parameters, including temperature, ancilla frequency, and system-bath coupling strength. We quantify the precision of parameter estimation using quantum Fisher information (QFI) and analyze the system dynamics in both transient and steady-state regimes. Our findings demonstrate that non-Markovianity substantially enhances parameter estimation in the transient regime, with specific interactions facilitating sustained information backflow and yielding higher QFI values. However, the performance of these interactions is contingent on the parameter under estimation and the operational regime. For instance, certain interactions become prominent in the transient regime but exhibit diminished utility in the steady state, whereas others maintain their effectiveness even at equilibrium. These results stress the importance of judiciously selecting interactions adapted to specific estimation objectives and operational regimes.
Multiparameter quantum estimation has emerged as a central task in quantum metrology. In this work, we investigate multiparameter quantum estimation in a hybrid exciton--optomechanical (EOM) system. The system consists of a semiconductor quantum well embedded inside a driven optomechanical microcavity, where the excitonic, optical, and mechanical modes interact coherently through exciton--photon and radiation-pressure couplings. Using the Gaussian-state formalism, we derive the covariance matrix of the steady-state quantum fluctuations and employ both the symmetric logarithmic derivative (SLD) and right logarithmic derivative (RLD) approaches to evaluate the quantum Fisher information matrix associated with the simultaneous estimation of the exciton--photon coupling strength ggg and the excitonic decay rate kxk_xkx​. We analyze the corresponding quantum Cramér--Rao bounds and determine the most informative precision limit governing the attainable estimation accuracy. The influence of several experimentally relevant parameters, including temperature, driving power, optomechanical coupling strength, and dissipation rates, is investigated in detail. Our results show that strong hybrid interactions and low-temperature regimes significantly enhance the estimation precision, whereas thermal fluctuations and dissipation processes deteriorate the metrological performance. Furthermore, we compare the ultimate quantum limits with experimentally feasible Gaussian measurement strategies based on homodyne and heterodyne detection. We show that heterodyne detection provides better estimation performance than homodyne schemes and can approach the optimal quantum precision limit in suitable parameter regimes.
Quantum metrology enables measurement sensitivities beyond classical limits by exploiting quantum resources. Among promising platforms, hybrid cavity–magnon systems—where microwave photons interact with collective spin excitations in magnetic materials—offer a versatile testbed for emerging quantum technologies. However, their performance hinges on precise knowledge of the cavity–magnon coupling strength. Here, we propose an experimentally feasible scheme to enhance the quantum estimation of this parameter by leveraging coherent feedback and parametric amplification. Using the Heisenberg–Langevin formalism, we linearize the system dynamics and compute both quantum (QFI) and classical Fisher information. Our analysis shows that optimal detuning, strong driving, and cryogenic temperatures below 0.1 K significantly improve estimation precision, while magnon dissipation and thermal noise degrade the QFI. Parametric amplification enhances precision when the gain and phase are optimally tuned, and coherent feedback yields even greater sensitivity at tailored phase shifts and reflectivities. Notably, their combination achieves the lowest estimation error and the highest robustness against thermal noise. Finally, we identify the cavity mode as the optimal probe, with homodyne detection nearly saturating the quantum limit under ideal conditions. These findings establish a robust pathway for high-precision, noise-resilient cavity–magnon coupling estimation.