arXiv:2610.35588

A low-volume cold-atom microwave clock with an additively manufactured cavity

Samuel A. Smith, Sean Dyer, Alan Bregazzi, Rajnandan Choudhury Das, Oliver S. Burrow, C. Affolderbach, G. Mileti, Erling Riis, Paul F. Griffin

Published Oct 26, 2026• 0 citations
arXivHTMLPDF

Abstract

We present the performance of a compact microwave interrogated atomic clock based on laser cooled $^{87}$$\rm{Rb}$ atoms. The clock utilizes a micro-fabricated grating magneto-optical trap (gMOT) to cool and trap atoms, and an additively manufactured microwave cavity for microwave interrogation. We demonstrate a signal-to-noise ratio (SNR) of $370$ at a 1 Hz bandwidth and mid-term instability of $6.7\times10^{-14}$ at an averaging time of $τ=3 \times 10^{4}$ s. In addition, a low cost mu-metal foil has been implemented on the vacuum chamber to reduce the quadratic Zeeman shift which was previously limiting stability beyond $τ= 10$ s.

DOI
10.48550/arxiv.2610.35588

Related papers

A compact cold-atom double-resonance clock

Alan Bregazzi, Etienne Batori, Ben Lewis +4 more

We present a demonstration of a cold-atom optical-microwave double resonance (DR) Ramsey clock utilising an additively manufactured loop-gap-resonator cavity and grating magneto-optical trap (GMOT). The use of additive manufacturing allows for complex cavity structures, more difficult to produce with traditional machining techniques, while the GMOT architecture significantly simplifies the optical system required to trap and cool the atomic sample. In the current demonstration a single laser is used to trap < 3 × 106 87Rb atoms, cool them to below 10 µK, optically pump and read-out state populations of the atoms after microwave interrogation. A Ramsey-type interrogation scheme is employed with an empirically evaluated optimum free evolution time of 10 ms, limited by the loss of signal due to atoms falling out of the read-out beam. We demonstrate a short-term stability of < 2×10−11τ−1/2, in reasonable agreement with the predicted short-term stability based on the signal to noise ratio of the measured Ramsey fringes. Excellent field homogeneity of the cavity microwave field is demonstrated though Rabi oscillations, while almost complete optical pumping and good field orientation is evidenced by Zeeman spectroscopy of the ground-state hyperfine energy levels. This work is a novel approach towards more compact and portable cold-atom microwave clocks with significant potential for further miniaturization of the system.

Optical and Quantum Sensing and Precision Metrology II•Mar 8, 2023•0 citations

An additive-manufactured microwave cavity for a compact cold-atom clock

Etienne Batori, Alan Bregazzi, Ben Lewis +4 more

We present an additive-manufactured microwave cavity for a Ramsey-type, double resonance, compact cold-atom clock. Atoms can be laser cooled inside the cavity using a grating magneto-optic trap with the cavity providing an excellent TE011-like mode while maintaining sufficient optical access for atomic detection. The cavity features a low Q-factor of 360 which conveniently reduces the cavity pulling of the future clock. Despite the potential porosity of the additive-manufacturing process, we demonstrate that the cavity is well-suited for vacuum. A preliminary clock setup using cold atoms allows for measuring the Zeeman spectrum and Rabi oscillations in the cavity which enables us to infer excellent field uniformity and homogeneity, respectively, across the volume accessed by the cold atoms. Ramsey spectroscopy is demonstrated, indicating that the cavity is suitable for clock applications. Finally, we discuss the limitations of the future clock.

arXiv:2305.02898•Journal of Applied Physics•Jun 8, 2023•4 citations

A cold-atom Ramsey clock with a low volume physics package

Alan Bregazzi, Etienne Batori, Ben Lewis +4 more

We demonstrate a Ramsey-type microwave clock interrogating the 6.835 GHz ground-state transition in cold [Formula: see text]Rb atoms loaded from a grating magneto-optical trap (GMOT) enclosed in an additively manufactured loop-gap resonator microwave cavity. A short-term stability of [Formula: see text] is demonstrated, in reasonable agreement with predictions from the signal-to-noise ratio of the measured Ramsey fringes. The cavity-grating package has a volume of [Formula: see text]67 cm[Formula: see text], ensuring an inherently compact system while the use of a GMOT drastically simplifies the optical requirements for laser cooled atoms. This work is another step towards the realisation of highly compact portable cold-atom frequency standards.

arXiv:2305.02944•Scientific Reports•Jan 9, 2024•20 citations

A compact cold atom cavity clock

Alan Bregazzi, Etienne Batori, Ben Lewis +4 more

Abstract A sample of laser cooled atoms are created inside an additively manufactured loop-gap microwave cavity using a grating magneto-optic trap requiring only a single laser cooling beam. Using a Ramsey excitation scheme with free evolution times of up to 20 ms and based on the 87Rb ground-state clock transition, we demonstrate a short-term stability of 1.5×10−11 τ −1/2, averaging down to 2×10−12 after 100 s. The short-term stability limit is found to be dominated by the signal to noise ratio of the Ramsey fringes while for longer timescales the limitation is magnetic field noise due to the experiment being magnetically unshielded. Potential improvements to the setup and its operation point to a viable route forward for a miniaturised atomic microwave clock.

Journal of Physics Conference Series•Nov 1, 2024•0 citations

Progress of a compact microwave clock based on atoms cooled with a diffractive optic

Rachel Elvin, Gregory W. Hoth, Michael W. Wright +6 more

An atomic clock based on a compact source of cold atoms and coherent population trapping (CPT) is an encouraging goal for future low-volume atomic frequency references. Our experiment seeks to investigate the performance of such a system by applying CPT in a high-contrast lin⊥lin polarisation scheme to our 87Rb grating magneto optical trap (GMOT) apparatus. In this paper, we report on our progress of improving short- term stability of our cold-atom CPT apparatus. Our recent measurements have shown a short-term stability of 5 x 10-11/√τ, with the ability to average down for times τ>100s.

SPIE eBooks•Feb 25, 2020•0 citations

High-performance coherent population trapping clock based on laser-cooled atoms

Xiaochi Liu, Ning Ru, Junyi Duan +3 more

We present a coherent population trapping clock system based on laser-cooled 87Rb atoms. The clock consists of a frequency-stabilized CPT interrogation laser and a cooling laser as well as a compact magneto-optical trap, a high-performance microwave synthesizer, and a signal detection system. The resonance signal in the continuous wave regime exhibits an absorption contrast of ∼ 50%. In the Ramsey interrogation method, the linewidth of the central fringe is 31.25 Hz. The system achieves fractional frequency stability of 2.4 × 10 − 11 / τ , which goes down to 1.8 × 10−13 at 20000 s. The results validate that cold atom interrogation can improve the long-term frequency stability of coherent population trapping clocks and holds the potential for developing compact/miniature cold atoms clocks.

Chinese Physics B•Oct 6, 2021•8 citations
We present the performance of a compact microwave interrogated atomic clock based on laser cooled ^{87}$$\rm{Rb} atoms. The clock utilizes a micro-fabricated grating magneto-optical trap (gMOT) to cool and trap atoms, and an additively manufactured microwave cavity for microwave interrogation. We demonstrate a signal-to-noise ratio (SNR) of 370370370 at a 1 Hz bandwidth and mid-term instability of 6.7×10−146.7\times10^{-14}6.7×10−14 at an averaging time of τ=3×104τ=3 \times 10^{4}τ=3×104 s. In addition, a low cost mu-metal foil has been implemented on the vacuum chamber to reduce the quadratic Zeeman shift which was previously limiting stability beyond τ=10τ= 10τ=10 s.
We present a demonstration of a cold-atom optical-microwave double resonance (DR) Ramsey clock utilising an additively manufactured loop-gap-resonator cavity and grating magneto-optical trap (GMOT). The use of additive manufacturing allows for complex cavity structures, more difficult to produce with traditional machining techniques, while the GMOT architecture significantly simplifies the optical system required to trap and cool the atomic sample. In the current demonstration a single laser is used to trap < 3 × 106 87Rb atoms, cool them to below 10 µK, optically pump and read-out state populations of the atoms after microwave interrogation. A Ramsey-type interrogation scheme is employed with an empirically evaluated optimum free evolution time of 10 ms, limited by the loss of signal due to atoms falling out of the read-out beam. We demonstrate a short-term stability of < 2×10−11τ−1/2, in reasonable agreement with the predicted short-term stability based on the signal to noise ratio of the measured Ramsey fringes. Excellent field homogeneity of the cavity microwave field is demonstrated though Rabi oscillations, while almost complete optical pumping and good field orientation is evidenced by Zeeman spectroscopy of the ground-state hyperfine energy levels. This work is a novel approach towards more compact and portable cold-atom microwave clocks with significant potential for further miniaturization of the system.
We present an additive-manufactured microwave cavity for a Ramsey-type, double resonance, compact cold-atom clock. Atoms can be laser cooled inside the cavity using a grating magneto-optic trap with the cavity providing an excellent TE011-like mode while maintaining sufficient optical access for atomic detection. The cavity features a low Q-factor of 360 which conveniently reduces the cavity pulling of the future clock. Despite the potential porosity of the additive-manufacturing process, we demonstrate that the cavity is well-suited for vacuum. A preliminary clock setup using cold atoms allows for measuring the Zeeman spectrum and Rabi oscillations in the cavity which enables us to infer excellent field uniformity and homogeneity, respectively, across the volume accessed by the cold atoms. Ramsey spectroscopy is demonstrated, indicating that the cavity is suitable for clock applications. Finally, we discuss the limitations of the future clock.
We demonstrate a Ramsey-type microwave clock interrogating the 6.835 GHz ground-state transition in cold [Formula: see text]Rb atoms loaded from a grating magneto-optical trap (GMOT) enclosed in an additively manufactured loop-gap resonator microwave cavity. A short-term stability of [Formula: see text] is demonstrated, in reasonable agreement with predictions from the signal-to-noise ratio of the measured Ramsey fringes. The cavity-grating package has a volume of [Formula: see text]67 cm[Formula: see text], ensuring an inherently compact system while the use of a GMOT drastically simplifies the optical requirements for laser cooled atoms. This work is another step towards the realisation of highly compact portable cold-atom frequency standards.
Abstract A sample of laser cooled atoms are created inside an additively manufactured loop-gap microwave cavity using a grating magneto-optic trap requiring only a single laser cooling beam. Using a Ramsey excitation scheme with free evolution times of up to 20 ms and based on the 87Rb ground-state clock transition, we demonstrate a short-term stability of 1.5×10−11 τ −1/2, averaging down to 2×10−12 after 100 s. The short-term stability limit is found to be dominated by the signal to noise ratio of the Ramsey fringes while for longer timescales the limitation is magnetic field noise due to the experiment being magnetically unshielded. Potential improvements to the setup and its operation point to a viable route forward for a miniaturised atomic microwave clock.
An atomic clock based on a compact source of cold atoms and coherent population trapping (CPT) is an encouraging goal for future low-volume atomic frequency references. Our experiment seeks to investigate the performance of such a system by applying CPT in a high-contrast lin⊥lin polarisation scheme to our 87Rb grating magneto optical trap (GMOT) apparatus. In this paper, we report on our progress of improving short- term stability of our cold-atom CPT apparatus. Our recent measurements have shown a short-term stability of 5 x 10-11/√τ, with the ability to average down for times τ>100s.
We present a coherent population trapping clock system based on laser-cooled 87Rb atoms. The clock consists of a frequency-stabilized CPT interrogation laser and a cooling laser as well as a compact magneto-optical trap, a high-performance microwave synthesizer, and a signal detection system. The resonance signal in the continuous wave regime exhibits an absorption contrast of ∼ 50%. In the Ramsey interrogation method, the linewidth of the central fringe is 31.25 Hz. The system achieves fractional frequency stability of 2.4 × 10 − 11 / τ , which goes down to 1.8 × 10−13 at 20000 s. The results validate that cold atom interrogation can improve the long-term frequency stability of coherent population trapping clocks and holds the potential for developing compact/miniature cold atoms clocks.