Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2605.16710

High-Frequency Thermal Noise in Michelson Interferometers

Daniel Graß, S. M. Vermeulen, I. A. O. MacMillan, Lee P. McCuller

Published May 15, 2026• 0 citations
arXivHTMLPDF

Abstract

Thermal noise in optics constrains the precision of optical experiments, including Michelson interferometers, optical clocks, and optomechanical sensors. While high-power optical experiments such as gravitational-wave detectors are currently limited mainly by quantum noise, new experiments incorporating recent insights from quantum metrology are being developed that evade the quantum shot noise background. In particular, Michelson interferometers that use photon-counting readout will look for weak, high-frequency signals. Since shot noise is no longer the dominant noise source with these readout schemes, it is important to accurately model thermal noise to characterize signals and design more sensitive experiments. However, previous modeling uses approximations that are no longer valid in these frequency regimes. In the MHz band, the quasistatic approximation does not apply. We therefore develop more general models of substrate and coating mechanical (Brownian) noise, substrate and coating thermoelastic noise, and coating thermorefractive noise. We validate the models with comparisons to previous low-frequency modeling and high-frequency spectra from an experiment that has already taken data, the Holometer. We then apply the new models to GQuEST, an experiment under construction.

DOI
10.48550/arxiv.2605.16710

Related papers

Squeezed light for the interferometric detection of high-frequency gravitational waves

Roman Schnabel, J. Harms, K. A. Strain +1 more

The quantum noise of the light field is a fundamental noise source in interferometric gravitational wave detectors. Injected squeezed light is capable of reducing the quantum noise contribution to the detector noise floor to values that surpass the so-called Standard-Quantum-Limit (SQL). In particular, squeezed light is useful for the detection of gravitational waves at high frequencies where interferometers are typically shot-noise limited, although the SQL might not be beaten in this case. We theoretically analyze the quantum noise of the signal-recycled laser interferometric gravitational-wave detector GEO600 with additional input and output optics, namely frequency-dependent squeezing of the vacuum state of light entering the dark port and frequency-dependent homodyne detection. We focus on the frequency range between 1 kHz and 10 kHz, where, although signal recycled, the detector is still shot-noise limited. It is found that the GEO600 detector with present design parameters will benefit from frequency dependent squeezed light. Assuming a squeezing strength of -6 dB in quantum noise variance, the interferometer will become thermal noise limited up to 4 kHz without further reduction of bandwidth. At higher frequencies the linear noise spectral density of GEO600 will still be dominated by shot-noise and improved by a factor of 10^{6dB/20dB}~2 according to the squeezing strength assumed. The interferometer might reach a strain sensitivity of 6x10^{-23} above 1 kHz (tunable) with a bandwidth of around 350 Hz. We propose a scheme to implement the desired frequency dependent squeezing by introducing an additional optical component to GEO600s signal-recycling cavity.

arXiv:gr-qc/0401119•Classical and Quantum Gravity•Feb 12, 2004•26 citations

Quantum correlation measurements in interferometric gravitational-wave detectors

V. V. Frolov, S. Kandhasamy, K. Izumi +97 more

Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational-wave detectors, such as the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the quantum properties of light can be used to distinguish these noises using correlation techniques. Particularly, in the first part of the paper we show estimations of the coating thermal noise and gas phase noise, hidden below the quantum shot noise in the Advanced LIGO sensitivity curve. We also make projections on the observatory sensitivity during the next science runs. In the second part of the paper we discuss the correlation technique that reveals the quantum radiation pressure noise from the background of classical noises and shot noise. We apply this technique to the Advanced LIGO data, collected during the first science run, and experimentally estimate the quantum correlations and quantum radiation pressure noise in the interferometer.

Physical Review Letters•Apr 1, 2017•0 citations

Michelson interferometry with quantum noise reduction

Takahisa Mitsui, Aoki, Kenichiro

A Michelson interferometer with noise reduction to sub-shot noise levels is proposed and realized. Multiple measurements of a single signal beam are taken and the quantum property of light plays an essential role in the principle underlying this interferometry. The method makes use of the coherent state of light and requires only a simple modification to the standard Michelson interferometer. The surface fluctuation spectra of liquids are measured using this method down to a few orders of magnitude below the shot noise level. The spectrum derived from hydrodynamical considerations agrees well with the observed results for water. However, for oil, slight deviations are seen at high frequencies ($\gtrsim1\,$MHz), perhaps indicating its more complex underlying physics. The measurement requires a relatively low light power and a short time, so that it has a wide range of applicability.

arXiv:1206.3828•Jun 18, 2012•0 citations

Review: Quantum noise in gravitational-wave interferometers

T. R. Corbitt, N. Mavalvala

We present an overview of quantum noise in gravitational-wave interferometers. Current gravitational-wave detectors are modified variants of a Michelson interferometer and the quantum noise limits are strongly influenced by the optical configuration of the interferometer. We describe recent developments in the treatment of quantum noise in the complex interferometers of present-day and future gravitational-wave detectors and explore prospects for beating the standard quantum limit by use of both injected and ponderomotive squeezing in future interferometers.

Journal of Optics B Quantum and Semiclassical Optics•Jul 28, 2004•78 citations

Quantum noise in gravitational wave interferometers: an overview and recent developments

T. R. Corbitt, N. Mavalvala

We present an overview of quantum noise in gravitational wave interferometers. Gravitational wave detectors are extensively modified variants of a Michelson interferometer and the quantum noise couplings are strongly influenced by the interferometer configuration. We describe recent developments in the treatment of quantum noise in the complex interferometer configurations of present-day and future gravitational-wave detectors. In addition, we explore prospects for the use of squeezed light in future interferometers, including consideration of the effects of losses, and the choice of optimal readout schemes.

arXiv:gr-qc/0306055•Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 16, 2003•6 citations

Analysis of a sub-shot-noise power recycled Michelson interferometer

Kirk McKenzie, B. C. Buchler, D. A. Shaddock +2 more

The sensitivity of interferometric gravitational wave detectors is ultimately limited by the 'quantum noise' of light. In this paper we compare results from a bench-top experiment and a theoretical model which show how squeezed states of light may be used to modify the quantum noise behaviour of a power recycled Michelson interferometer. We develop a simple theoretical model of the experiment and find close agreement of theoretical and experimental results. We measure quantum noise suppression of 2.3 dB and demonstrate the lock stability of the experiment for long periods.

Classical and Quantum Gravity•Feb 12, 2004•8 citations
Thermal noise in optics constrains the precision of optical experiments, including Michelson interferometers, optical clocks, and optomechanical sensors. While high-power optical experiments such as gravitational-wave detectors are currently limited mainly by quantum noise, new experiments incorporating recent insights from quantum metrology are being developed that evade the quantum shot noise background. In particular, Michelson interferometers that use photon-counting readout will look for weak, high-frequency signals. Since shot noise is no longer the dominant noise source with these readout schemes, it is important to accurately model thermal noise to characterize signals and design more sensitive experiments. However, previous modeling uses approximations that are no longer valid in these frequency regimes. In the MHz band, the quasistatic approximation does not apply. We therefore develop more general models of substrate and coating mechanical (Brownian) noise, substrate and coating thermoelastic noise, and coating thermorefractive noise. We validate the models with comparisons to previous low-frequency modeling and high-frequency spectra from an experiment that has already taken data, the Holometer. We then apply the new models to GQuEST, an experiment under construction.
The quantum noise of the light field is a fundamental noise source in interferometric gravitational wave detectors. Injected squeezed light is capable of reducing the quantum noise contribution to the detector noise floor to values that surpass the so-called Standard-Quantum-Limit (SQL). In particular, squeezed light is useful for the detection of gravitational waves at high frequencies where interferometers are typically shot-noise limited, although the SQL might not be beaten in this case. We theoretically analyze the quantum noise of the signal-recycled laser interferometric gravitational-wave detector GEO600 with additional input and output optics, namely frequency-dependent squeezing of the vacuum state of light entering the dark port and frequency-dependent homodyne detection. We focus on the frequency range between 1 kHz and 10 kHz, where, although signal recycled, the detector is still shot-noise limited. It is found that the GEO600 detector with present design parameters will benefit from frequency dependent squeezed light. Assuming a squeezing strength of -6 dB in quantum noise variance, the interferometer will become thermal noise limited up to 4 kHz without further reduction of bandwidth. At higher frequencies the linear noise spectral density of GEO600 will still be dominated by shot-noise and improved by a factor of 10^{6dB/20dB}~2 according to the squeezing strength assumed. The interferometer might reach a strain sensitivity of 6x10^{-23} above 1 kHz (tunable) with a bandwidth of around 350 Hz. We propose a scheme to implement the desired frequency dependent squeezing by introducing an additional optical component to GEO600s signal-recycling cavity.
Quantum fluctuations in the phase and amplitude quadratures of light set limitations on the sensitivity of modern optical instruments. The sensitivity of the interferometric gravitational-wave detectors, such as the Advanced Laser Interferometer Gravitational-Wave Observatory (LIGO), is limited by quantum shot noise, quantum radiation pressure noise, and a set of classical noises. We show how the quantum properties of light can be used to distinguish these noises using correlation techniques. Particularly, in the first part of the paper we show estimations of the coating thermal noise and gas phase noise, hidden below the quantum shot noise in the Advanced LIGO sensitivity curve. We also make projections on the observatory sensitivity during the next science runs. In the second part of the paper we discuss the correlation technique that reveals the quantum radiation pressure noise from the background of classical noises and shot noise. We apply this technique to the Advanced LIGO data, collected during the first science run, and experimentally estimate the quantum correlations and quantum radiation pressure noise in the interferometer.
A Michelson interferometer with noise reduction to sub-shot noise levels is proposed and realized. Multiple measurements of a single signal beam are taken and the quantum property of light plays an essential role in the principle underlying this interferometry. The method makes use of the coherent state of light and requires only a simple modification to the standard Michelson interferometer. The surface fluctuation spectra of liquids are measured using this method down to a few orders of magnitude below the shot noise level. The spectrum derived from hydrodynamical considerations agrees well with the observed results for water. However, for oil, slight deviations are seen at high frequencies (≳1 \gtrsim1\,≳1MHz), perhaps indicating its more complex underlying physics. The measurement requires a relatively low light power and a short time, so that it has a wide range of applicability.
We present an overview of quantum noise in gravitational-wave interferometers. Current gravitational-wave detectors are modified variants of a Michelson interferometer and the quantum noise limits are strongly influenced by the optical configuration of the interferometer. We describe recent developments in the treatment of quantum noise in the complex interferometers of present-day and future gravitational-wave detectors and explore prospects for beating the standard quantum limit by use of both injected and ponderomotive squeezing in future interferometers.
We present an overview of quantum noise in gravitational wave interferometers. Gravitational wave detectors are extensively modified variants of a Michelson interferometer and the quantum noise couplings are strongly influenced by the interferometer configuration. We describe recent developments in the treatment of quantum noise in the complex interferometer configurations of present-day and future gravitational-wave detectors. In addition, we explore prospects for the use of squeezed light in future interferometers, including consideration of the effects of losses, and the choice of optimal readout schemes.
The sensitivity of interferometric gravitational wave detectors is ultimately limited by the 'quantum noise' of light. In this paper we compare results from a bench-top experiment and a theoretical model which show how squeezed states of light may be used to modify the quantum noise behaviour of a power recycled Michelson interferometer. We develop a simple theoretical model of the experiment and find close agreement of theoretical and experimental results. We measure quantum noise suppression of 2.3 dB and demonstrate the lock stability of the experiment for long periods.