Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2604.08515

Measurement-induced state transitions across the fluxonium qubit landscape

Alex A. Chapple, Boris M. Varbanov, Alexander McDonald, Alexandre Blais

quant-phSubmitted Apr 9, 2026• Announced Apr 10, 2026• 0 citations
arXivHTMLPDF

Abstract

Understanding the mechanisms that limit high-fidelity readout in circuit quantum electrodynamics is essential for its optimization. Multi-photon resonances are understood to be a limiting factor, causing population transfer from the computational states to higher-energy states under drive. This effect, known as measurement-induced state transitions, has been extensively studied for the transmon qubit. While this exploration has begun for the fluxonium qubit, a systematic study of this effect is lacking. Here, we bridge this gap by theoretically studying measurement-induced state transitions in the fluxonium qubit over a wide range of parameters, comprising essentially all experimentally explored ranges. We find that lighter fluxoniums are less susceptible to these state transitions when compared to their heavier counterparts. We attribute this effect to the combination of lower density of multi-photon resonances, a smaller requisite coupling for a given dispersive shift, and a more harmonic-like structure of the charge operator. We confirm the validity of our analysis by performing time-dependent readout simulations. Finally, we consider the impact of the superinductor's array modes on measurement-induced state transitions over a large range of parameters.

Related papers

Impact of Josephson-Junction Array Modes on Fluxonium Readout

Shraddha Singh, Gil Refael, Aashish A. Clerk +1 more

Dispersive readout of superconducting qubits is often limited by readout-drive-induced transitions between qubit levels. While there is a growing understanding of such effects in transmon qubits, the case of highly nonlinear fluxonium qubits is more complex. We theoretically analyze measurement-induced state transitions (MISTs) during the dispersive readout of a fluxonium qubit. We focus on a new mechanism: a simultaneous transition/excitation involving the qubit and an internal mode of the Josephson-junction array in the fluxonium circuit. Using an adiabatic Floquet approach, we show that these new kinds of MIST processes can be relevant when using realistic circuit parameters and relatively low readout drive powers. They also contribute to excess qubit dephasing even after a measurement is complete. In addition to outlining basic mechanisms, we also investigate the dependence of such transitions on the circuit parameters. We find that with a judicious choice of frequency allocations or coupling strengths, these parasitic processes can most likely be avoided.

arXiv:2412.14788•PRX Quantum•Aug 26, 2025•10 citations

Experimental Characterization and Modeling of Measurement-Induced State-Transitions in a Fluxonium Superconducting Qubit

Martijn F. S. Zwanenburg, Jinlun Hu, Eugene Y. Huang +3 more

Superconducting qubits are most often measured using dispersive readout, which, ideally, implements a projective quantum non-demolition (QND) measurement. While a larger readout drive can increase the signal and, thus, reduce discrimination errors in the readout, strong microwave drives may also cause non-QND errors by driving the qubit to a state outside the computational subspace. In this work, we experimentally characterize measurement-induced state transitions (MIST) in a fluxonium qubit over its full external flux range. We further numerically calculate the MIST errors, and find that the theory accurately predicts eleven experimentally identified regions with increased MIST. In addition to transitions to higher fluxonium levels, we also find that, at certain flux points, MIST errors are dominated by transitions that include the transmission-line-like array modes of the fluxonium's superinductor. The excellent match between theory and experiment validates that the models accurately predict the occurrence of MIST in these systems, and further highlights the influence of array modes in fluxonium readout.

quant-pharXiv:2606.17866•Jun 17, 2026•0 citations

Measurement-induced state transitions in multi-qubit transmon processors

Baptiste Hoyau, Alexander McDonald, Boris M. Varbanov +2 more

Dispersive readout of the transmon qubit in circuit QED is known to lose its quantum non-demolition character at small to moderate measurement drive amplitudes. This phenomenon is understood to originate from Laundau-Zener transitions at accidental multi-photon resonances, where $n$ drive photons can promote the transmon by $m$ levels. This interpretation has been shown to be in agreement with experiments characterizing the dispersive readout of a single transmon. The impact of these measurement-induced state transition (MIST) of a transmon embedded in a multi-qubit chip, however, remains largely unexplored. Here, we show that the presence of other components, such as qubits and couplers, can affect the MIST threshold of a measured transmon. To arrive at these results, we present a general method to characterize measurement-induced transition when the qubit under readout is coupled to other circuit elements, a ubiquitous situation in circuit QED-based quantum processors. As an example, we consider the case of two transmon qubits, and we show that the spectator qubit can be impacted by the measurement-induced transition of the readout qubit and, conversely, that the presence of the spectator qubit can lower the MIST threshold of the readout qubit. Finally, we explore how adding a coupler mode between the two qubits further modifies these effects.

quant-pharXiv:2606.05010•Jun 4, 2026•0 citations

Readout-induced leakage of the fluxonium qubit

Aayam Bista, Matthew Thibodeau, Ke Nie +3 more

Dispersive readout is widely used to perform high-fidelity measurement of superconducting qubits. Much work has been focused on the qubit readout fidelity, which depends on the achievable signal-to-noise ratio and the qubit relaxation time. As groups have pushed to increase readout fidelity by increasing readout photon number, dispersive readout has been shown to strongly affect the postmeasurement qubit state. Such effects hinder the effectiveness of quantum error correction, which requires measurements that both have high readout fidelity and are quantum nondemolition (QND). Here, we experimentally investigate non-QND effects in the fluxonium. We map out the state evolution of fluxonium qubits in the presence of resonator photons and observe that these photons induce transitions in the fluxonium both within and outside the qubit subspace. We numerically model our system and find that transitions to higher-excited states and coupling to an external spurious mode are necessary to explain observed non-QND effects.

arXiv:2501.17807•Physical Review Applied•Feb 9, 2026•5 citations

Flux-pulse-assisted readout of a fluxonium qubit

Taryn V. Stefanski, Christian Kraglund Andersen

Much attention has focused on the transmon architecture for large-scale superconducting quantum devices; however, the fluxonium qubit has emerged as a possible successor. With a shunting inductor in parallel to a Josephson junction, the fluxonium offers larger anharmonicity and stronger protection against dielectric loss, leading to higher coherence times as compared to conventional transmon qubits. The interplay between the inductive and Josephson energy potentials of the fluxonium qubit leads to a rich dispersive-shift landscape when tuning the external flux. Here, we propose to exploit the features in the dispersive shift to improve qubit readout. Specifically, we report on theoretical simulations showing improved readout times and error rates by performing the readout at a flux-bias point with large dispersive shift. We expand the scheme to include different error channels and show that with an integration time of 155 ns, flux-pulse-assisted readout offers about a 5 -times improvement in the signal-to-noise ratio. Moreover, we show that the performance improvement persists in the presence of finite measurement efficiency combined with quasistatic flux noise and also when considering the increased Purcell rate at the flux-pulse-assisted readout point. We suggest a set of reasonable energy parameters for the fluxonium architecture that will allow for the implementation of our proposed flux-pulse-assisted readout scheme.

arXiv:2309.17286•Physical Review Applied•Jul 30, 2024•8 citations

High-fidelity QND readout and measurement back-action in a tantalum-based high-coherence fluxonium qubit

Gaurav Bothara, Srijita Das, Kishor V. Salunkhe +4 more

Implementing a precise measurement of the quantum state of a qubit is critical for building a practical quantum processor, as it plays an important role in state initialization and quantum error correction. While the transmon qubit has been the most commonly used design in small- to medium-scale processors, the fluxonium qubit is emerging as a strong alternative with the potential for high-fidelity gate operation as a result of the high anharmonicity and high coherence achievable due to its unique design. Here, we explore the measurement characteristics of a tantalum-based high-coherence fluxonium qubit and demonstrate single-shot measurement fidelity (assignment fidelity) of 96.2% ± 0.5% and 97.8% ± 0.4% without and with the use of a Josephson parametric amplifier, respectively. We study the back-action of the measurement photons on the qubit and measure a QND fidelity of 99.0% ± 0.3%. We find that the measurement fidelity and the QND nature are limited by state-mixing errors, and our results suggest that a careful study of measurement-induced transitions in the fluxonium is needed to further optimize the readout performance.

APL Quantum•Apr 9, 2025•5 citations
Understanding the mechanisms that limit high-fidelity readout in circuit quantum electrodynamics is essential for its optimization. Multi-photon resonances are understood to be a limiting factor, causing population transfer from the computational states to higher-energy states under drive. This effect, known as measurement-induced state transitions, has been extensively studied for the transmon qubit. While this exploration has begun for the fluxonium qubit, a systematic study of this effect is lacking. Here, we bridge this gap by theoretically studying measurement-induced state transitions in the fluxonium qubit over a wide range of parameters, comprising essentially all experimentally explored ranges. We find that lighter fluxoniums are less susceptible to these state transitions when compared to their heavier counterparts. We attribute this effect to the combination of lower density of multi-photon resonances, a smaller requisite coupling for a given dispersive shift, and a more harmonic-like structure of the charge operator. We confirm the validity of our analysis by performing time-dependent readout simulations. Finally, we consider the impact of the superinductor's array modes on measurement-induced state transitions over a large range of parameters.
Dispersive readout of superconducting qubits is often limited by readout-drive-induced transitions between qubit levels. While there is a growing understanding of such effects in transmon qubits, the case of highly nonlinear fluxonium qubits is more complex. We theoretically analyze measurement-induced state transitions (MISTs) during the dispersive readout of a fluxonium qubit. We focus on a new mechanism: a simultaneous transition/excitation involving the qubit and an internal mode of the Josephson-junction array in the fluxonium circuit. Using an adiabatic Floquet approach, we show that these new kinds of MIST processes can be relevant when using realistic circuit parameters and relatively low readout drive powers. They also contribute to excess qubit dephasing even after a measurement is complete. In addition to outlining basic mechanisms, we also investigate the dependence of such transitions on the circuit parameters. We find that with a judicious choice of frequency allocations or coupling strengths, these parasitic processes can most likely be avoided.
Superconducting qubits are most often measured using dispersive readout, which, ideally, implements a projective quantum non-demolition (QND) measurement. While a larger readout drive can increase the signal and, thus, reduce discrimination errors in the readout, strong microwave drives may also cause non-QND errors by driving the qubit to a state outside the computational subspace. In this work, we experimentally characterize measurement-induced state transitions (MIST) in a fluxonium qubit over its full external flux range. We further numerically calculate the MIST errors, and find that the theory accurately predicts eleven experimentally identified regions with increased MIST. In addition to transitions to higher fluxonium levels, we also find that, at certain flux points, MIST errors are dominated by transitions that include the transmission-line-like array modes of the fluxonium's superinductor. The excellent match between theory and experiment validates that the models accurately predict the occurrence of MIST in these systems, and further highlights the influence of array modes in fluxonium readout.
Dispersive readout of the transmon qubit in circuit QED is known to lose its quantum non-demolition character at small to moderate measurement drive amplitudes. This phenomenon is understood to originate from Laundau-Zener transitions at accidental multi-photon resonances, where nnn drive photons can promote the transmon by mmm levels. This interpretation has been shown to be in agreement with experiments characterizing the dispersive readout of a single transmon. The impact of these measurement-induced state transition (MIST) of a transmon embedded in a multi-qubit chip, however, remains largely unexplored. Here, we show that the presence of other components, such as qubits and couplers, can affect the MIST threshold of a measured transmon. To arrive at these results, we present a general method to characterize measurement-induced transition when the qubit under readout is coupled to other circuit elements, a ubiquitous situation in circuit QED-based quantum processors. As an example, we consider the case of two transmon qubits, and we show that the spectator qubit can be impacted by the measurement-induced transition of the readout qubit and, conversely, that the presence of the spectator qubit can lower the MIST threshold of the readout qubit. Finally, we explore how adding a coupler mode between the two qubits further modifies these effects.
Dispersive readout is widely used to perform high-fidelity measurement of superconducting qubits. Much work has been focused on the qubit readout fidelity, which depends on the achievable signal-to-noise ratio and the qubit relaxation time. As groups have pushed to increase readout fidelity by increasing readout photon number, dispersive readout has been shown to strongly affect the postmeasurement qubit state. Such effects hinder the effectiveness of quantum error correction, which requires measurements that both have high readout fidelity and are quantum nondemolition (QND). Here, we experimentally investigate non-QND effects in the fluxonium. We map out the state evolution of fluxonium qubits in the presence of resonator photons and observe that these photons induce transitions in the fluxonium both within and outside the qubit subspace. We numerically model our system and find that transitions to higher-excited states and coupling to an external spurious mode are necessary to explain observed non-QND effects.
Much attention has focused on the transmon architecture for large-scale superconducting quantum devices; however, the fluxonium qubit has emerged as a possible successor. With a shunting inductor in parallel to a Josephson junction, the fluxonium offers larger anharmonicity and stronger protection against dielectric loss, leading to higher coherence times as compared to conventional transmon qubits. The interplay between the inductive and Josephson energy potentials of the fluxonium qubit leads to a rich dispersive-shift landscape when tuning the external flux. Here, we propose to exploit the features in the dispersive shift to improve qubit readout. Specifically, we report on theoretical simulations showing improved readout times and error rates by performing the readout at a flux-bias point with large dispersive shift. We expand the scheme to include different error channels and show that with an integration time of 155 ns, flux-pulse-assisted readout offers about a 5 -times improvement in the signal-to-noise ratio. Moreover, we show that the performance improvement persists in the presence of finite measurement efficiency combined with quasistatic flux noise and also when considering the increased Purcell rate at the flux-pulse-assisted readout point. We suggest a set of reasonable energy parameters for the fluxonium architecture that will allow for the implementation of our proposed flux-pulse-assisted readout scheme.
Implementing a precise measurement of the quantum state of a qubit is critical for building a practical quantum processor, as it plays an important role in state initialization and quantum error correction. While the transmon qubit has been the most commonly used design in small- to medium-scale processors, the fluxonium qubit is emerging as a strong alternative with the potential for high-fidelity gate operation as a result of the high anharmonicity and high coherence achievable due to its unique design. Here, we explore the measurement characteristics of a tantalum-based high-coherence fluxonium qubit and demonstrate single-shot measurement fidelity (assignment fidelity) of 96.2% ± 0.5% and 97.8% ± 0.4% without and with the use of a Josephson parametric amplifier, respectively. We study the back-action of the measurement photons on the qubit and measure a QND fidelity of 99.0% ± 0.3%. We find that the measurement fidelity and the QND nature are limited by state-mixing errors, and our results suggest that a careful study of measurement-induced transitions in the fluxonium is needed to further optimize the readout performance.