Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2603.12312

Qubit measurement and backaction in a multimode nonreciprocal system

B. T. Miller, Lindsay Orr, A. Metelmann, F. Lecocq

quant-phcond-mat.mes-hallSubmitted Mar 12, 2026• Announced Mar 16, 2026• 0 citations
arXivHTMLPDF

Abstract

High fidelity qubit readout is a cornerstone for quantum information protocols. In traditional superconducting qubit readout, a chain of microwave amplifiers and nonreciprocal components aid in detecting the qubit's state with tolerable added noise and backaction. However, the loss, size, and magnetic field of standard nonreciprocal components have sparked a decades-long search for more efficient and scalable alternatives. One prominent approach employs networks of parametrically coupled modes to achieve nonreciprocity. While this class of devices can be directly integrated with the qubit's readout cavity, current understanding of the resulting single quantum system is substantially lacking. Here we provide a first-principles theoretical tool to understand and design networks of linear modes integrated with embedded qubits. We utilize this theory to inform and analyze the experimental implementation of a qubit readout with an integrated three-mode nonreciprocal system. In doing so, we achieve excellent agreement between the experimental and theoretical qubit measurement and dephasing rates. We then theoretically analyze the same system operated as an integrated nonreciprocal amplifier, predicting high efficiency for reasonable experimental parameters.

Comments
40 pages, 22 figures

Related papers

Efficient Qubit Measurement with a Nonreciprocal Microwave Amplifier

Florent Lecocq, Leonardo Ranzani, G. A. Peterson +5 more

The act of observing a quantum object fundamentally perturbs its state, resulting in a random walk toward an eigenstate of the measurement operator. Ideally, the measurement is responsible for all dephasing of the quantum state. In practice, imperfections in the measurement apparatus limit or corrupt the flow of information required for quantum feedback protocols, an effect quantified by the measurement efficiency. Here, we demonstrate the efficient measurement of a superconducting qubit using a nonreciprocal parametric amplifier to directly monitor the microwave field of a readout cavity. By mitigating the losses between the cavity and the amplifier, we achieve a measurement efficiency of (72±4)%. The directionality of the amplifier protects the readout cavity and qubit from excess backaction caused by amplified vacuum fluctuations. In addition to providing tools for further improving the fidelity of strong projective measurement, this work creates a test bed for the experimental study of ideal weak measurements, and it opens the way toward quantum feedback protocols based on weak measurement such as state stabilization or error correction.

arXiv:2009.08863•Physical Review Letters•Jan 13, 2021•30 citations

Efficient and Low-Backaction Quantum Measurement Using a Chip-Scale Detector

Eric I. Rosenthal, C. M. F. Schneider, M. Malnou +13 more

Superconducting qubits are a leading platform for scalable quantum computing and quantum error correction. One feature of this platform is the ability to perform projective measurements orders of magnitude more quickly than qubit decoherence times. Such measurements are enabled by the use of quantum-limited parametric amplifiers in conjunction with ferrite circulators-magnetic devices which provide isolation from noise and decoherence due to amplifier backaction. Because these nonreciprocal elements have limited performance and are not easily integrated on chip, it has been a long-standing goal to replace them with a scalable alternative. Here, we demonstrate a solution to this problem by using a superconducting switch to control the coupling between a qubit and amplifier. Doing so, we measure a transmon qubit using a single, chip-scale device to provide both parametric amplification and isolation from the bulk of amplifier backaction. This measurement is also fast, high fidelity, and has 70% efficiency, comparable to the best that has been reported in any superconducting qubit measurement. As such, this work constitutes a high-quality platform for the scalable measurement of superconducting qubits.

arXiv:2008.03805•Physical Review Letters•Mar 3, 2021•32 citations

High-Fidelity Qubit Readout Using Interferometric Directional Josephson Devices

Baleegh Abdo, Oblesh Jinka, Nicholas T. Bronn +2 more

Nonreciprocal microwave devices, such as circulators and isolators, are needed in high-fidelity qubit readout schemes to unidirectionally route the readout signals and protect the qubits against noise coming from the output chain.However, cryogenic circulators and isolators are prohibitive in scalable superconducting architectures because they rely on magnetic materials.Here we report a fast (750 ns) high-fidelity (95%) quantum nondemolition readout of a coherent superconducting qubit (T 1 = 52 μs, T 2E = 35 μs) without any nonreciprocal magnetic devices.We use in our readout chain a microwave-controlled qubit readout multichip module (QRMCM) that integrates interferometric directional Josephson devices consisting of an isolator and a reconfigurable isolator or amplifier device, and an off-chip low-pass filter.Using the QRMCM, we demonstrate isolation up to 45 dB within 13 MHz, when both directional devices are operated as isolators, and low-noise amplification in excess of 10 dB within a dynamical bandwidth of 10 MHz, when the reconfigurable device is operated as an amplifier.We also investigate the dependence of the qubit coherence times T ϕ and T 2E on the isolation response of the QRMCM, which we control in situ using the microwave drives feeding the isolators.Furthermore, by directly comparing the QRMCM performance with that of a state-of-art configuration (with T 2E ≈ 2T 1 ) that uses a pair of wideband magnetic isolators, we find that the excess pure dephasing measured with the QRMCM (for which T 2E ≈ T 1 ) is likely limited by the residual thermal photon population in the readout resonator.Improved versions of the QRMCM could replace magnetic circulators and isolators in large superconducting quantum processors.

arXiv:2006.01918•PRX Quantum•Dec 28, 2021•20 citations

On-chip single-pump interferometric Josephson isolator for quantum measurements

Baleegh Abdo, Oblesh Jinka, Nicholas T. Bronn +2 more

Nonreciprocal microwave devices, such as circulators and isolators, are critical in high-fidelity qubit readout schemes. They unidirectionally route the readout signals and protect the qubits against noise coming from the output chain. However, cryogenic circulators and isolators are prohibitive in scalable superconducting architectures because they rely on magneto-optical effects. Here, we realize an on-chip, single-microwave-pump Josephson ISolator (JIS), formed by coupling two nondegenerate Josephson mixers in an interferometric scheme. We unravel the interplay between the orientation parity of the magnetic fluxes, biasing the mixers, and the JIS directionality. Furthermore, we build a motherboard, which integrates the JIS and other superconducting components, including a Josephson directional amplifier, into a printed circuit and use it to read out a qubit with 92% fidelity, while maintaining 75% of its T2E. Improved versions of this motherboard could replace magnetic circulators and isolators in large superconducting quantum processors.

•Jun 2, 2020•5 citations

Optimization of superconducting flux qubit readout using near-quantum-limited amplifiers

Jedediah E Johnson

Though superconducting qubits offer the potential for a scalable quantum computing architecture, the high-fidelity readout necessary to execute practical algorithms has thus far remained elusive. Moreover, achievements toward high fidelity have been accompanied by either long measurement times or demolition of the quantum state. In this dissertation, we address these issues with the novel integration of two ultralow-noise, superconducting amplifiers into separate dispersive flux qubit measurements. We first demonstrate a flux qubit inductively coupled to a 1.294-GHz nonlinear oscillator formed by a capacitively shunted DC SQUID. The frequency of the oscillator is modulated by the state of the qubit and is detected via microwave reflectometry. A microstrip SQUID (Superconducting QUantum Interference Device) amplifier (MSA) is used to increase the sensitivity of the measurement over that of a semiconductor amplifier. In the second experiment, we report measurements of a flux qubit coupled via a shared inductance to a quasi-lumped element 5.78-GHz readout resonator formed by the parallel combination of an interdigitated capacitor and a meander line inductor. The system noise is substantially reduced by a near-quantum-limited Josephson parametric amplifier (paramp).We present measurements of increased fidelity and reduced measurement backaction using the MSA at readout excitation levels as low as one hundredth of a photon in the readout resonator, observing a 4.5-fold increase in the readout visibility. Furthermore, at low readout excitation levels below one tenth of a photon in the readout resonator, no reduction in T1 is observed, potentially enabling continuous monitoring of the qubit state. Using the paramp, we demonstrate a continuous, high-fidelity readout with sufficient bandwidth and signal-to-noise ratio to resolve quantum jumps in the flux qubit. This is enabled by a readout which discriminates between the readout pointer state distributions to an error below one part in 1000. This, along with the ability to make many successive readouts in a time T1, permits the use of heralding to ensure initialization to a fiducial state, such as the ground state. This method enables us to eliminate errors due to spurious thermal population, increasing the fidelity to 93.9%. Finally, we use heralding to introduce a simple, fast qubit reset protocol without changing the system parameters to induce Purcell relaxation.

•Jan 1, 2012•2 citations

Optimization of superconducting flux qubit readout using near-quantum-limited amplifiers - eScholarship

Jedediah E Johnson

Though superconducting qubits offer the potential for a scalable quantum computing architecture, the high-fidelity readout necessary to execute practical algorithms has thus far remained elusive. Moreover, achievements toward high fidelity have been accompanied by either long measurement times or demolition of the quantum state. In this dissertation, we address these issues with the novel integration of two ultralow-noise, superconducting amplifiers into separate dispersive flux qubit measurements. We first demonstrate a flux qubit inductively coupled to a 1.294-GHz nonlinear oscillator formed by a capacitively shunted DC SQUID. The frequency of the oscillator is modulated by the state of the qubit and is detected via microwave reflectometry. A microstrip SQUID (Superconducting QUantum Interference Device) amplifier (MSA) is used to increase the sensitivity of the measurement over that of a semiconductor amplifier. In the second experiment, we report measurements of a flux qubit coupled via a shared inductance to a quasi-lumped element 5.78-GHz readout resonator formed by the parallel combination of an interdigitated capacitor and a meander line inductor. The system noise is substantially reduced by a near-quantum-limited Josephson parametric amplifier (paramp).We present measurements of increased fidelity and reduced measurement backaction using the MSA at readout excitation levels as low as one hundredth of a photon in the readout resonator, observing a 4.5-fold increase in the readout visibility. Furthermore, at low readout excitation levels below one tenth of a photon in the readout resonator, no reduction in T1 is observed, potentially enabling continuous monitoring of the qubit state. Using the paramp, we demonstrate a continuous, high-fidelity readout with sufficient bandwidth and signal-to-noise ratio to resolve quantum jumps in the flux qubit. This is enabled by a readout which discriminates between the readout pointer state distributions to an error below one part in 1000. This, along with the ability to make many successive readouts in a time T1, permits the use of heralding to ensure initialization to a fiducial state, such as the ground state. This method enables us to eliminate errors due to spurious thermal population, increasing the fidelity to 93.9%. Finally, we use heralding to introduce a simple, fast qubit reset protocol without changing the system parameters to induce Purcell relaxation.

•Jan 1, 2012•0 citations
High fidelity qubit readout is a cornerstone for quantum information protocols. In traditional superconducting qubit readout, a chain of microwave amplifiers and nonreciprocal components aid in detecting the qubit's state with tolerable added noise and backaction. However, the loss, size, and magnetic field of standard nonreciprocal components have sparked a decades-long search for more efficient and scalable alternatives. One prominent approach employs networks of parametrically coupled modes to achieve nonreciprocity. While this class of devices can be directly integrated with the qubit's readout cavity, current understanding of the resulting single quantum system is substantially lacking. Here we provide a first-principles theoretical tool to understand and design networks of linear modes integrated with embedded qubits. We utilize this theory to inform and analyze the experimental implementation of a qubit readout with an integrated three-mode nonreciprocal system. In doing so, we achieve excellent agreement between the experimental and theoretical qubit measurement and dephasing rates. We then theoretically analyze the same system operated as an integrated nonreciprocal amplifier, predicting high efficiency for reasonable experimental parameters.
The act of observing a quantum object fundamentally perturbs its state, resulting in a random walk toward an eigenstate of the measurement operator. Ideally, the measurement is responsible for all dephasing of the quantum state. In practice, imperfections in the measurement apparatus limit or corrupt the flow of information required for quantum feedback protocols, an effect quantified by the measurement efficiency. Here, we demonstrate the efficient measurement of a superconducting qubit using a nonreciprocal parametric amplifier to directly monitor the microwave field of a readout cavity. By mitigating the losses between the cavity and the amplifier, we achieve a measurement efficiency of (72±4)%. The directionality of the amplifier protects the readout cavity and qubit from excess backaction caused by amplified vacuum fluctuations. In addition to providing tools for further improving the fidelity of strong projective measurement, this work creates a test bed for the experimental study of ideal weak measurements, and it opens the way toward quantum feedback protocols based on weak measurement such as state stabilization or error correction.
Superconducting qubits are a leading platform for scalable quantum computing and quantum error correction. One feature of this platform is the ability to perform projective measurements orders of magnitude more quickly than qubit decoherence times. Such measurements are enabled by the use of quantum-limited parametric amplifiers in conjunction with ferrite circulators-magnetic devices which provide isolation from noise and decoherence due to amplifier backaction. Because these nonreciprocal elements have limited performance and are not easily integrated on chip, it has been a long-standing goal to replace them with a scalable alternative. Here, we demonstrate a solution to this problem by using a superconducting switch to control the coupling between a qubit and amplifier. Doing so, we measure a transmon qubit using a single, chip-scale device to provide both parametric amplification and isolation from the bulk of amplifier backaction. This measurement is also fast, high fidelity, and has 70% efficiency, comparable to the best that has been reported in any superconducting qubit measurement. As such, this work constitutes a high-quality platform for the scalable measurement of superconducting qubits.
Nonreciprocal microwave devices, such as circulators and isolators, are needed in high-fidelity qubit readout schemes to unidirectionally route the readout signals and protect the qubits against noise coming from the output chain.However, cryogenic circulators and isolators are prohibitive in scalable superconducting architectures because they rely on magnetic materials.Here we report a fast (750 ns) high-fidelity (95%) quantum nondemolition readout of a coherent superconducting qubit (T 1 = 52 μs, T 2E = 35 μs) without any nonreciprocal magnetic devices.We use in our readout chain a microwave-controlled qubit readout multichip module (QRMCM) that integrates interferometric directional Josephson devices consisting of an isolator and a reconfigurable isolator or amplifier device, and an off-chip low-pass filter.Using the QRMCM, we demonstrate isolation up to 45 dB within 13 MHz, when both directional devices are operated as isolators, and low-noise amplification in excess of 10 dB within a dynamical bandwidth of 10 MHz, when the reconfigurable device is operated as an amplifier.We also investigate the dependence of the qubit coherence times T ϕ and T 2E on the isolation response of the QRMCM, which we control in situ using the microwave drives feeding the isolators.Furthermore, by directly comparing the QRMCM performance with that of a state-of-art configuration (with T 2E ≈ 2T 1 ) that uses a pair of wideband magnetic isolators, we find that the excess pure dephasing measured with the QRMCM (for which T 2E ≈ T 1 ) is likely limited by the residual thermal photon population in the readout resonator.Improved versions of the QRMCM could replace magnetic circulators and isolators in large superconducting quantum processors.
Nonreciprocal microwave devices, such as circulators and isolators, are critical in high-fidelity qubit readout schemes. They unidirectionally route the readout signals and protect the qubits against noise coming from the output chain. However, cryogenic circulators and isolators are prohibitive in scalable superconducting architectures because they rely on magneto-optical effects. Here, we realize an on-chip, single-microwave-pump Josephson ISolator (JIS), formed by coupling two nondegenerate Josephson mixers in an interferometric scheme. We unravel the interplay between the orientation parity of the magnetic fluxes, biasing the mixers, and the JIS directionality. Furthermore, we build a motherboard, which integrates the JIS and other superconducting components, including a Josephson directional amplifier, into a printed circuit and use it to read out a qubit with 92% fidelity, while maintaining 75% of its T2E. Improved versions of this motherboard could replace magnetic circulators and isolators in large superconducting quantum processors.
Though superconducting qubits offer the potential for a scalable quantum computing architecture, the high-fidelity readout necessary to execute practical algorithms has thus far remained elusive. Moreover, achievements toward high fidelity have been accompanied by either long measurement times or demolition of the quantum state. In this dissertation, we address these issues with the novel integration of two ultralow-noise, superconducting amplifiers into separate dispersive flux qubit measurements. We first demonstrate a flux qubit inductively coupled to a 1.294-GHz nonlinear oscillator formed by a capacitively shunted DC SQUID. The frequency of the oscillator is modulated by the state of the qubit and is detected via microwave reflectometry. A microstrip SQUID (Superconducting QUantum Interference Device) amplifier (MSA) is used to increase the sensitivity of the measurement over that of a semiconductor amplifier. In the second experiment, we report measurements of a flux qubit coupled via a shared inductance to a quasi-lumped element 5.78-GHz readout resonator formed by the parallel combination of an interdigitated capacitor and a meander line inductor. The system noise is substantially reduced by a near-quantum-limited Josephson parametric amplifier (paramp).We present measurements of increased fidelity and reduced measurement backaction using the MSA at readout excitation levels as low as one hundredth of a photon in the readout resonator, observing a 4.5-fold increase in the readout visibility. Furthermore, at low readout excitation levels below one tenth of a photon in the readout resonator, no reduction in T1 is observed, potentially enabling continuous monitoring of the qubit state. Using the paramp, we demonstrate a continuous, high-fidelity readout with sufficient bandwidth and signal-to-noise ratio to resolve quantum jumps in the flux qubit. This is enabled by a readout which discriminates between the readout pointer state distributions to an error below one part in 1000. This, along with the ability to make many successive readouts in a time T1, permits the use of heralding to ensure initialization to a fiducial state, such as the ground state. This method enables us to eliminate errors due to spurious thermal population, increasing the fidelity to 93.9%. Finally, we use heralding to introduce a simple, fast qubit reset protocol without changing the system parameters to induce Purcell relaxation.
Though superconducting qubits offer the potential for a scalable quantum computing architecture, the high-fidelity readout necessary to execute practical algorithms has thus far remained elusive. Moreover, achievements toward high fidelity have been accompanied by either long measurement times or demolition of the quantum state. In this dissertation, we address these issues with the novel integration of two ultralow-noise, superconducting amplifiers into separate dispersive flux qubit measurements. We first demonstrate a flux qubit inductively coupled to a 1.294-GHz nonlinear oscillator formed by a capacitively shunted DC SQUID. The frequency of the oscillator is modulated by the state of the qubit and is detected via microwave reflectometry. A microstrip SQUID (Superconducting QUantum Interference Device) amplifier (MSA) is used to increase the sensitivity of the measurement over that of a semiconductor amplifier. In the second experiment, we report measurements of a flux qubit coupled via a shared inductance to a quasi-lumped element 5.78-GHz readout resonator formed by the parallel combination of an interdigitated capacitor and a meander line inductor. The system noise is substantially reduced by a near-quantum-limited Josephson parametric amplifier (paramp).We present measurements of increased fidelity and reduced measurement backaction using the MSA at readout excitation levels as low as one hundredth of a photon in the readout resonator, observing a 4.5-fold increase in the readout visibility. Furthermore, at low readout excitation levels below one tenth of a photon in the readout resonator, no reduction in T1 is observed, potentially enabling continuous monitoring of the qubit state. Using the paramp, we demonstrate a continuous, high-fidelity readout with sufficient bandwidth and signal-to-noise ratio to resolve quantum jumps in the flux qubit. This is enabled by a readout which discriminates between the readout pointer state distributions to an error below one part in 1000. This, along with the ability to make many successive readouts in a time T1, permits the use of heralding to ensure initialization to a fiducial state, such as the ground state. This method enables us to eliminate errors due to spurious thermal population, increasing the fidelity to 93.9%. Finally, we use heralding to introduce a simple, fast qubit reset protocol without changing the system parameters to induce Purcell relaxation.