arXiv:2603.06988 · Physical Review Applied

In situ magnetic-field stabilization for quantum-gas experiments

E Gvozdiovas, Ana Valdés-Curiel, Qiyu Liang, E. D. Mercado-Gutiérrez, A. Piñeiro, J. Tao, Dimitrios Trypogeorgos, M. Zhao, Ian B. Spielman

Published Jun 24, 2026• 0 citations
arXivHTMLPDF

Abstract

We demonstrate a minimally-destructive in situ technique for measuring and stabilizing slowly-drifting magnetic fields in ultracold-atom experiments. While conventional magnetic-field sensors such as Hall, giant magnetoresistive, or fluxgate-based devices are broadly used, their accuracy, precision and dynamic range can be limited. In addition, these sensors are typically positioned at least several centimeters away from the in-vacuum atomic system, as their operation creates perturbing magnetic fields, and their placement is limited by geometric constraints imposed by the vacuum system. We overcome these issues by using the atomic system itself as a built-in magnetometer. To that end, we employ a pair of weak measurements to determine the Zeeman splitting -- and thereby the magnetic field -- of a magnetically sensitive atomic transition. We provide closed-form expressions quantifying the trade-offs between measurement noise, dynamic range, and atom loss. This procedure is demonstrated with ultracold Rb-87, weakly measured using partial-transfer absorption imaging. We then incorporate a Kalman filter to stabilize the magnetic field; this eliminated long-term drift in the ambient field (as high as ~70 nT/hr) in exchange for a modest increase in shot-to-shot variability from 1.8(2) nT to 2.0(2) nT.

DOI
10.1103/vpnl-xpj7

Related papers

Direct control of high magnetic fields for cold atom experiments based on NV centers

Alexander Hesse, Kerim Köster, Jakob M. Steiner +5 more

Abstract In ultracold quantum gases, the interactions between the individual atoms can be controlled by applying magnetic bias fields. As magnetic field fluctuations limit the precision here, typically a feedback loop needs to be employed to regulate the current through a pair of Helmholtz coils. No commercially available magnetic field sensor allows to measure large fields directly with high enough precision, leading to many unsatisfactory solutions being used in experiments. Here, we demonstrate a direct magnetic field stabilization in a regime previously not accessible, using NV centers as the magnetic field sensor. This allows us to measure and stabilize fields of 4.66 mT down to 12 nT RMS noise over the course of 24 h, measured on a 1 Hz bandwidth. We achieve a control of better than 1 ppm after 20 min of integration time, ensuring high long-term stability for experiments. This approach extends direct magnetic field control to strong magnetic fields, which could enable new precise quantum simulations in this regime.

arXiv:2003.08101•New Journal of Physics•Feb 1, 2021•8 citations

Probing magnetic fields near atom traps via commercially available sensor modules

Lucas Eisenhart

Sensors are constant companions in our everyday lives and find countless applications in science. In this work we try to find sensors that are able to record magnetic field changes affecting trapped ions in our experiments. For this we assume that the magnetic field changes inside the vacuum chamber containing the trap in our experiment are the same as those measured by the sensor in the vicinity of the trap. To characterize three different sensors, we generate magnetic field offsets with a current-carrying wire, permanent magnet or a pair of coils. By isolating the sensors from the surroundings with a μ metal shield, we create a test environment under similar conditions. We showed that the fluxgate sensor is about a factor of 27500 more sensitive than the Hall sensor and a factor of 10 less sensitive than the atom itself as a sensor. We recognize that the noise of the electronics of the data acquisition system limits the performance of the fluxgate and Hall sensor. The fluxgate sensor, in contrast to the Hall sensor, turns out to be a suitable choice for monitoring magnetic field changes during experiments with ions.

•Jan 1, 2022•0 citations

Ultra-low noise magnetic field for quantum gases

Xiao-Tian Xu, Zong-Yao Wang, Rui-Heng Jiao +3 more

A ultralow noise magnetic field is essential for many branches of scientific research. Examples include experiments conducted on ultracold atoms, quantum simulations, and precision measurements. In ultracold atom experiments specifically, a bias magnetic field will often serve as a quantization axis and be applied for Zeeman splitting. As atomic states are usually sensitive to magnetic fields, a magnetic field characterized by ultralow noise as well as high stability is typically required for experimentation. For this study, a bias magnetic field is successfully stabilized at 14.5 G, with the root mean square value of the noise reduced to 18.5 μG (1.28 ppm) by placing μ-metal magnetic shields together with a dynamical feedback circuit. Long-time instability is also regulated consistently below 7 μG. The level of noise exhibited in the bias magnetic field is further confirmed by evaluating the coherence time of a Bose-Einstein condensate characterized by Rabi oscillation. It is concluded that this approach can be applied to other physical systems as well.

arXiv:1904.11642•Review of Scientific Instruments•May 1, 2019•46 citations

In-Situ Measurement of Electrical-Heating-Induced Magnetic Field for an Atomic Magnetometer

Jixi Lu, Jing Wang, Ke Yang +4 more

Electrical heating elements, which are widely used to heat the vapor cell of ultrasensitive atomic magnetometers, inevitably produce a magnetic field interference. In this paper, we propose a novel measurement method of the amplitude of electrical-heating-induced magnetic field for an atomic magnetometer. In contrast to conventional methods, this method can be implemented in the atomic magnetometer itself without the need for extra magnetometers. It can distinguish between different sources of magnetic fields sensed by the atomic magnetometer, and measure the three-axis components of the magnetic field generated by the electrical heater and the temperature sensor. The experimental results demonstrate that the measurement uncertainty of the heater’s magnetic field is less than 0.2 nT along the x-axis, 1.0 nT along the y-axis, and 0.4 nT along the z-axis. The measurement uncertainty of the temperature sensor’s magnetic field is less than 0.02 nT along all three axes. This method has the advantage of measuring the in-situ magnetic field, so it is especially suitable for miniaturized and chip-scale atomic magnetometers, where the cell is extremely small and in close proximity to the heater and the temperature sensor.

Sensors•Mar 25, 2020•38 citations

High-sensitivity operation of an unshielded single cell radio-frequency atomic magnetometer

Han Yao, Benjamin Maddox, Ferruccio Renzoni

Real-world applications of atomic magnetometers require the ability to operate them with high-sensitivity in the presence of magnetic noise. In the present work, high-sensitivity operation of unshielded atomic magnetometers in a magnetically noisy environment is demonstrated. The distinguishing feature of the demonstrated approach is the implementation of active in-situ bias field stabilization using multiple fluxgate magnetometers. This is combined with the use of a counter-propagating pump and triple-pass probe configuration, to maximize the atomic polarization and the probe rotation respectively, so to reach high-sensitivity. The improvement in sensitivity of the unshielded system with respect to previous realizations is fully characterized, with the contributions of the different modifications of the apparatus individually quantified. The presented set-up is suitable for the detection of long-range magnetic fields, where shielding or differential measurements using multi-sensor set-ups do not constitute viable options.

Optics Express•Oct 21, 2022•29 citations

Spatially-selective in situ magnetometry of ultracold atomic clouds

Ottó Elíasson, Robert Heck, Jens S Laustsen +5 more

Abstract We demonstrate novel implementations of high-precision optical magnetometers which allow for spatially-selective and spatially-resolved in situ measurements using cold atomic clouds. These are realised by using shaped dispersive probe beams combined with spatially-resolved balanced homodyne detection. Two magnetometer sequences are discussed: a vectorial magnetometer, which yields sensitivities two orders of magnitude better compared to a previous realisation and a Larmor magnetometer capable of measuring absolute magnetic fields. We characterise the dependence of single-shot precision on the size of the analysed region for the vectorial magnetometer and provide a lower bound for the measurement precision of magnetic field gradients for the Larmor magnetometer. Finally, we give an outlook on how dynamic trapping potentials combined with selective probing can be used to realise enhanced quantum simulations in quantum gas microscopes.

arXiv:1811.01798•Journal of Physics B Atomic Molecular and Optical Physics•Mar 1, 2019•18 citations
We demonstrate a minimally-destructive in situ technique for measuring and stabilizing slowly-drifting magnetic fields in ultracold-atom experiments. While conventional magnetic-field sensors such as Hall, giant magnetoresistive, or fluxgate-based devices are broadly used, their accuracy, precision and dynamic range can be limited. In addition, these sensors are typically positioned at least several centimeters away from the in-vacuum atomic system, as their operation creates perturbing magnetic fields, and their placement is limited by geometric constraints imposed by the vacuum system. We overcome these issues by using the atomic system itself as a built-in magnetometer. To that end, we employ a pair of weak measurements to determine the Zeeman splitting -- and thereby the magnetic field -- of a magnetically sensitive atomic transition. We provide closed-form expressions quantifying the trade-offs between measurement noise, dynamic range, and atom loss. This procedure is demonstrated with ultracold Rb-87, weakly measured using partial-transfer absorption imaging. We then incorporate a Kalman filter to stabilize the magnetic field; this eliminated long-term drift in the ambient field (as high as ~70 nT/hr) in exchange for a modest increase in shot-to-shot variability from 1.8(2) nT to 2.0(2) nT.
Abstract In ultracold quantum gases, the interactions between the individual atoms can be controlled by applying magnetic bias fields. As magnetic field fluctuations limit the precision here, typically a feedback loop needs to be employed to regulate the current through a pair of Helmholtz coils. No commercially available magnetic field sensor allows to measure large fields directly with high enough precision, leading to many unsatisfactory solutions being used in experiments. Here, we demonstrate a direct magnetic field stabilization in a regime previously not accessible, using NV centers as the magnetic field sensor. This allows us to measure and stabilize fields of 4.66 mT down to 12 nT RMS noise over the course of 24 h, measured on a 1 Hz bandwidth. We achieve a control of better than 1 ppm after 20 min of integration time, ensuring high long-term stability for experiments. This approach extends direct magnetic field control to strong magnetic fields, which could enable new precise quantum simulations in this regime.
Sensors are constant companions in our everyday lives and find countless applications in science. In this work we try to find sensors that are able to record magnetic field changes affecting trapped ions in our experiments. For this we assume that the magnetic field changes inside the vacuum chamber containing the trap in our experiment are the same as those measured by the sensor in the vicinity of the trap. To characterize three different sensors, we generate magnetic field offsets with a current-carrying wire, permanent magnet or a pair of coils. By isolating the sensors from the surroundings with a μ metal shield, we create a test environment under similar conditions. We showed that the fluxgate sensor is about a factor of 27500 more sensitive than the Hall sensor and a factor of 10 less sensitive than the atom itself as a sensor. We recognize that the noise of the electronics of the data acquisition system limits the performance of the fluxgate and Hall sensor. The fluxgate sensor, in contrast to the Hall sensor, turns out to be a suitable choice for monitoring magnetic field changes during experiments with ions.
A ultralow noise magnetic field is essential for many branches of scientific research. Examples include experiments conducted on ultracold atoms, quantum simulations, and precision measurements. In ultracold atom experiments specifically, a bias magnetic field will often serve as a quantization axis and be applied for Zeeman splitting. As atomic states are usually sensitive to magnetic fields, a magnetic field characterized by ultralow noise as well as high stability is typically required for experimentation. For this study, a bias magnetic field is successfully stabilized at 14.5 G, with the root mean square value of the noise reduced to 18.5 μG (1.28 ppm) by placing μ-metal magnetic shields together with a dynamical feedback circuit. Long-time instability is also regulated consistently below 7 μG. The level of noise exhibited in the bias magnetic field is further confirmed by evaluating the coherence time of a Bose-Einstein condensate characterized by Rabi oscillation. It is concluded that this approach can be applied to other physical systems as well.
Electrical heating elements, which are widely used to heat the vapor cell of ultrasensitive atomic magnetometers, inevitably produce a magnetic field interference. In this paper, we propose a novel measurement method of the amplitude of electrical-heating-induced magnetic field for an atomic magnetometer. In contrast to conventional methods, this method can be implemented in the atomic magnetometer itself without the need for extra magnetometers. It can distinguish between different sources of magnetic fields sensed by the atomic magnetometer, and measure the three-axis components of the magnetic field generated by the electrical heater and the temperature sensor. The experimental results demonstrate that the measurement uncertainty of the heater’s magnetic field is less than 0.2 nT along the x-axis, 1.0 nT along the y-axis, and 0.4 nT along the z-axis. The measurement uncertainty of the temperature sensor’s magnetic field is less than 0.02 nT along all three axes. This method has the advantage of measuring the in-situ magnetic field, so it is especially suitable for miniaturized and chip-scale atomic magnetometers, where the cell is extremely small and in close proximity to the heater and the temperature sensor.
Real-world applications of atomic magnetometers require the ability to operate them with high-sensitivity in the presence of magnetic noise. In the present work, high-sensitivity operation of unshielded atomic magnetometers in a magnetically noisy environment is demonstrated. The distinguishing feature of the demonstrated approach is the implementation of active in-situ bias field stabilization using multiple fluxgate magnetometers. This is combined with the use of a counter-propagating pump and triple-pass probe configuration, to maximize the atomic polarization and the probe rotation respectively, so to reach high-sensitivity. The improvement in sensitivity of the unshielded system with respect to previous realizations is fully characterized, with the contributions of the different modifications of the apparatus individually quantified. The presented set-up is suitable for the detection of long-range magnetic fields, where shielding or differential measurements using multi-sensor set-ups do not constitute viable options.
Abstract We demonstrate novel implementations of high-precision optical magnetometers which allow for spatially-selective and spatially-resolved in situ measurements using cold atomic clouds. These are realised by using shaped dispersive probe beams combined with spatially-resolved balanced homodyne detection. Two magnetometer sequences are discussed: a vectorial magnetometer, which yields sensitivities two orders of magnitude better compared to a previous realisation and a Larmor magnetometer capable of measuring absolute magnetic fields. We characterise the dependence of single-shot precision on the size of the analysed region for the vectorial magnetometer and provide a lower bound for the measurement precision of magnetic field gradients for the Larmor magnetometer. Finally, we give an outlook on how dynamic trapping potentials combined with selective probing can be used to realise enhanced quantum simulations in quantum gas microscopes.