Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2602.23712

Real-time Amplitude and Phase Estimation of AC Fields with Diamond Spins

Christopher T. -K. Lew, Samuel A. Wilkinson, Nicholas Gillespie, Brant C. Gibson, David A. Broadway, Jean-Philippe Tetienne

cond-mat.mes-hallquant-phSubmitted Feb 27, 2026• Announced Mar 2, 2026
arXivHTMLPDF

Abstract

Nitrogen-vacancy centers in diamond have been shown to be capable of detecting AC magnetic fields with high sensitivity, spectral resolution, and spatial resolution. However, most studies so far have focused on the regime of time-averaged or time-correlated measurements, while little attention has been paid to the single-shot regime. Here we show that the amplitude and phase of an AC field can be retrieved from a single pair of two consecutive measurements. We demonstrate this concept by measuring a 4 MHz AC field with a per-shot amplitude and phase sensitivity of 78 nT and 63 mrad, respectively, at a temporal resolution of 320 us. We also investigate the effects and quantify the errors resulting from probe frequency detunings, as well as operating in the strong field regime. Moreover, we showcase the ability of the measurement protocol to dynamically change the probe frequency in real-time. This work advances the use of NV centers for real-time measurements of AC magnetic fields.

Related papers

Phase sensitive quantum magnetometry imaging using ensemble NV center in diamond on wide field optics

Mizuno, Kosuke, Hitoshi Ishiwata, Y. MASUYAMA +2 more

Nitrogen—Vacancy (NV) center in diamond can detect tiny magnetic field due to relative long coherence time even at room temperature. Its optical accessibility and capability of thin-film formation provide us an interesting sensing modality such as wide field imaging. We have reported phase sensitive protocol for ac magnetic field designed for wide field setup.[1] In this study we demonstrate an application of phase sensitive protocol; measuring distribution of ac magnetic field strength by phase sensing. Previous methods of multi-pulse quantum sensing such as XY8 realize quite high sensitivity of ac magnetic field. Since XY8 has dependencies on strength and phase of ac magnetic field, it is necessary to adjust ac phase to an optimal point in order to obtain a best sensitivity, and we cannot distinguish the effect of amplitude and phase. Recent studies have showed utilizing time-domain information is effective for improving frequency resolution of quantum sensing,[2,3] and we found same technique is also effective for simultaneous measurement of strength and phase. Here we propose a robust method for amplitude estimation by phase sensing. We added another signal for reference, then sensing phase difference between target signal and reference can be converted into amplitude. Conventional XY8 sensing is based upon fluorescence measurement which can be affected easily by many obstacles such as stray light, autofluorescence, and fringes of excitation laser. In the other hand, our method can be more robust because it is based on phase measurement. Nothing can change the phase except absorption of ac signal. This work was supported by MEXT Q-LEAP, CAO PRISM, Japan. [1] Mizuno et al., AIP advances 2018 [2][3] Boss, Schmitt

•Jun 4, 2019•0 citations

Nanoscale covariance magnetometry with diamond quantum sensors

Jared Rovny, Zhiyang Yuan, Mattias Fitzpatrick +6 more

Nitrogen vacancy (NV) centers in diamond are atom-scale defects that can be used to sense magnetic fields with high sensitivity and spatial resolution. Typically, the magnetic field is measured by averaging sequential measurements of single NV centers, or by spatial averaging over ensembles of many NV centers, which provides mean values that contain no nonlocal information about the relationship between two points separated in space or time. Here, we propose and implement a sensing modality whereby two or more NV centers are measured simultaneously, and we extract temporal and spatial correlations in their signals that would otherwise be inaccessible. We demonstrate measurements of correlated applied noise using spin-to-charge readout of two NV centers and implement a spectral reconstruction protocol for disentangling local and nonlocal noise sources.

arXiv:2209.08703•Science•Dec 22, 2022•75 citations

Simultaneous amplitude and phase imaging of AC magnetic signal on wide field setup

Kosuke Mizuno, Hitoshi Ishiwata, Y. MASUYAMA +2 more

The nitrogen-vacancy center in diamond is an exquisite solid-state sensor based upon quantum nature. Numerous studies have shown that dynamical decoupling, such as an XY8 sequence, provides us a high sensitivity for an oscillating magnetic field parametrized by amplitude and phase. However, there are some drawbacks. (1) A measurement using XY8 requires a careful adjustment of timings between XY8 sequences and the target signal. (2) The XY8 has an intricate dependence on both parameters, so it is not applicable in a situation that both parameters simultaneously change. (3) It is impossible to measure both parameters simultaneous, and they have to be measured severally. In this study, we present that Qdyne1-3, a quantum-classical hybrid protocol, solves them, consisted of sequential and stroboscopic measurements. The Qdyne does not require a timing adjustment before itself, has an intuitive dependency on both parameters, and let us a simultaneous measurement of both amplitude and phase. Moreover, we implemented it on a widefield of view. The large observation area of widefield modality and the high spatial resolution of NV center pave the way for a tiny-scale inspection by Eddy-current, which established sensors cannot detect.

•Dec 17, 2019•0 citations

High-frequency resolution diamond nitrogen-vacancy center wide-spectrum imaging technology

Yuanyuan Shen, Bo Wang, Dongqian Ke +10 more

High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.

Acta Physica Sinica•Jan 1, 2024•0 citations

Sensitive measurement of phase shift of an AC magnetic field by quantum sensing with multiple-pulse decoupling sequences

T. Ishikawa, Akio Yoshizawa, Yasunori Mawatari +2 more

Magnetometry utilizing a spin qubit in a solid state possesses high sensitivity. In particular, a magnetic sensor with a high spatial resolution can be achieved with the electron-spin states of a nitrogen-vacancy (NV) center in the diamond. In this study, we demonstrated that NV quantum sensing based on multiple-pulse decoupling sequences can sensitively measure not only the amplitude but also the phase shift of an alternating-current (AC) magnetic field. In the AC magnetometry based on decoupling sequences, the maximum phase accumulation of the NV spin due to an AC-field can be generally obtained when the π-pulse period in the sequences matches the half time period of the field and the relative phase difference between the sequences and the field is zero. By contrast, the NV quantum sensor acquires no phase accumulation if the relative phase difference is π/2. Thus, this phase-accumulation condition does not have any advantage for the magnetometry. However, we revealed that the nonphase-accumulation condition is available for detecting a very small phase shift of an AC-field from its initial phase. Measurements of the real part and the imaginary part of AC impedance require the amplitude and the phase information of an AC-field, and thus, this finding is expected to provide a guide for realizing sensitive measurement of AC impedance in the micrometer and nanometer scales.

arXiv:1808.03784•Journal of Applied Physics•Aug 12, 2019•2 citations

Application of phase estimation algorithms to improve diamond spin magnetometry

Naufer Nusran

Precision measurements of weak magnetic fields with nanoscale spatial resolution is an outstanding challenge in many fields including medicine, biology, material science and physical science. It has already been demonstrated that a single electronic spin formed by a defect color center in diamond, known as the nitrogen-vacancy (NV) center, can serve as a highly sensitive magnetometer with nanoscale resolution, even under ambient conditions. However, standard quantum sensing methods have significant drawbacks. These include the limited dynamic range due to quantum phase ambiguity, the non-linearity in sensitivity over the detectable field range, the requirement of prior knowledge of a working point for accurate deconvolution, etc. This thesis explores novel quantum control techniques such as the use of phase estimation algorithms (PEA) for magnetic field detection to address these issues. Unlike in the standard approach, PEA readout is linearly dependent on the field being sensed. PEA employed on oscillating (AC) magnetic fields can not only detect unknown field amplitudes but also allows detection of the field phase. The thesis also compares the performance of nonadaptive-PEA (NAPEA) with that of adaptive-PEA (QPEA) and conclude that NAPEA is superior to QPEA due to (a) better sensitivity on average, (b) consistency in sensitivity throughout the full field range, (c) comparatively less demanding measurement fidelity, and (d) for simplicity in its experimental realization. The techniques developed here can potentially have broad applicability to a wide variety of solid-state quantum systems and in the field of quantum control and measurement.

•May 29, 2014•0 citations
Nitrogen-vacancy centers in diamond have been shown to be capable of detecting AC magnetic fields with high sensitivity, spectral resolution, and spatial resolution. However, most studies so far have focused on the regime of time-averaged or time-correlated measurements, while little attention has been paid to the single-shot regime. Here we show that the amplitude and phase of an AC field can be retrieved from a single pair of two consecutive measurements. We demonstrate this concept by measuring a 4 MHz AC field with a per-shot amplitude and phase sensitivity of 78 nT and 63 mrad, respectively, at a temporal resolution of 320 us. We also investigate the effects and quantify the errors resulting from probe frequency detunings, as well as operating in the strong field regime. Moreover, we showcase the ability of the measurement protocol to dynamically change the probe frequency in real-time. This work advances the use of NV centers for real-time measurements of AC magnetic fields.
Nitrogen—Vacancy (NV) center in diamond can detect tiny magnetic field due to relative long coherence time even at room temperature. Its optical accessibility and capability of thin-film formation provide us an interesting sensing modality such as wide field imaging. We have reported phase sensitive protocol for ac magnetic field designed for wide field setup.[1] In this study we demonstrate an application of phase sensitive protocol; measuring distribution of ac magnetic field strength by phase sensing. Previous methods of multi-pulse quantum sensing such as XY8 realize quite high sensitivity of ac magnetic field. Since XY8 has dependencies on strength and phase of ac magnetic field, it is necessary to adjust ac phase to an optimal point in order to obtain a best sensitivity, and we cannot distinguish the effect of amplitude and phase. Recent studies have showed utilizing time-domain information is effective for improving frequency resolution of quantum sensing,[2,3] and we found same technique is also effective for simultaneous measurement of strength and phase. Here we propose a robust method for amplitude estimation by phase sensing. We added another signal for reference, then sensing phase difference between target signal and reference can be converted into amplitude. Conventional XY8 sensing is based upon fluorescence measurement which can be affected easily by many obstacles such as stray light, autofluorescence, and fringes of excitation laser. In the other hand, our method can be more robust because it is based on phase measurement. Nothing can change the phase except absorption of ac signal. This work was supported by MEXT Q-LEAP, CAO PRISM, Japan. [1] Mizuno et al., AIP advances 2018 [2][3] Boss, Schmitt
Nitrogen vacancy (NV) centers in diamond are atom-scale defects that can be used to sense magnetic fields with high sensitivity and spatial resolution. Typically, the magnetic field is measured by averaging sequential measurements of single NV centers, or by spatial averaging over ensembles of many NV centers, which provides mean values that contain no nonlocal information about the relationship between two points separated in space or time. Here, we propose and implement a sensing modality whereby two or more NV centers are measured simultaneously, and we extract temporal and spatial correlations in their signals that would otherwise be inaccessible. We demonstrate measurements of correlated applied noise using spin-to-charge readout of two NV centers and implement a spectral reconstruction protocol for disentangling local and nonlocal noise sources.
The nitrogen-vacancy center in diamond is an exquisite solid-state sensor based upon quantum nature. Numerous studies have shown that dynamical decoupling, such as an XY8 sequence, provides us a high sensitivity for an oscillating magnetic field parametrized by amplitude and phase. However, there are some drawbacks. (1) A measurement using XY8 requires a careful adjustment of timings between XY8 sequences and the target signal. (2) The XY8 has an intricate dependence on both parameters, so it is not applicable in a situation that both parameters simultaneously change. (3) It is impossible to measure both parameters simultaneous, and they have to be measured severally. In this study, we present that Qdyne1-3, a quantum-classical hybrid protocol, solves them, consisted of sequential and stroboscopic measurements. The Qdyne does not require a timing adjustment before itself, has an intuitive dependency on both parameters, and let us a simultaneous measurement of both amplitude and phase. Moreover, we implemented it on a widefield of view. The large observation area of widefield modality and the high spatial resolution of NV center pave the way for a tiny-scale inspection by Eddy-current, which established sensors cannot detect.
High-resolution wide-spectrum measurement techniques have important applications in fields such as astronomy, wireless communication, and medical imaging. Nitrogen-vacancy (NV) center in diamond is well known for its high stability, high sensitivity, real-time monitoring, single-point detection, and suitability for long-term measurement, and has an outstanding choice for spectrum analyzers. Currently, spectrum analyzers based on NV centers as detectors can perform real-time spectrum analysis in the range of several tens of gigahertz, but their frequency resolution is limited to a MHz level. In this study, we construct a quantum diamond microwave spectrum imaging system by combining continuous wave-mixing techniques. According to the spin-related properties of the NV center in diamond, we implement optical pumping by 532 nm green laser light illuminating the diamond NV center. A spherical magnet is used to produce a magnetic field gradient along the direction of the diamond crystal. By adjusting the size and direction of the magnetic field gradient, spatial encoding of the resonance frequency of the NV center is achieved. The magnetic field gradient induces the Zeeman effect on the diamond surface at different positions, generating corresponding ODMR signals. Through accurate programming, we coordinate the frequency scanning step size of the microwave source with the camera exposure and image storage time, and synchronize them circularly according to the order of image acquisition. Ultimately, after algorithmic processing, we successfully obtain comprehensive spectrum data in a range from 900 MHz to 6.0 GHz. Within the measurable spectrum range, the system employs continuous wave-mixing, simultaneously applying resonant microwaves and slightly detuning auxiliary microwaves to effectively excite the NV center. This method triggers off microwave interference effects, disrupting the balance between laser-induced polarization and microwave-induced spontaneous relaxation. Specifically, microwave interference causes the phase and amplitude of the fluorescence signal to change, leading to the generation of alternating current fluorescence signals. This further enhances the response of the NV magnetometer to weak microwave signals. The method enables the system to achieve a frequency resolution of 1 Hz in the measurable spectrum range, and it can separately measure the frequency resolution of multiple frequency points with a frequency step size of 1 MHz. The research results indicate that the wide-spectrum measurement based on NV centers can achieve sub-hertz frequency resolution, providing robust technical support for future spectrum analysis and applications.
Magnetometry utilizing a spin qubit in a solid state possesses high sensitivity. In particular, a magnetic sensor with a high spatial resolution can be achieved with the electron-spin states of a nitrogen-vacancy (NV) center in the diamond. In this study, we demonstrated that NV quantum sensing based on multiple-pulse decoupling sequences can sensitively measure not only the amplitude but also the phase shift of an alternating-current (AC) magnetic field. In the AC magnetometry based on decoupling sequences, the maximum phase accumulation of the NV spin due to an AC-field can be generally obtained when the π-pulse period in the sequences matches the half time period of the field and the relative phase difference between the sequences and the field is zero. By contrast, the NV quantum sensor acquires no phase accumulation if the relative phase difference is π/2. Thus, this phase-accumulation condition does not have any advantage for the magnetometry. However, we revealed that the nonphase-accumulation condition is available for detecting a very small phase shift of an AC-field from its initial phase. Measurements of the real part and the imaginary part of AC impedance require the amplitude and the phase information of an AC-field, and thus, this finding is expected to provide a guide for realizing sensitive measurement of AC impedance in the micrometer and nanometer scales.
Precision measurements of weak magnetic fields with nanoscale spatial resolution is an outstanding challenge in many fields including medicine, biology, material science and physical science. It has already been demonstrated that a single electronic spin formed by a defect color center in diamond, known as the nitrogen-vacancy (NV) center, can serve as a highly sensitive magnetometer with nanoscale resolution, even under ambient conditions. However, standard quantum sensing methods have significant drawbacks. These include the limited dynamic range due to quantum phase ambiguity, the non-linearity in sensitivity over the detectable field range, the requirement of prior knowledge of a working point for accurate deconvolution, etc. This thesis explores novel quantum control techniques such as the use of phase estimation algorithms (PEA) for magnetic field detection to address these issues. Unlike in the standard approach, PEA readout is linearly dependent on the field being sensed. PEA employed on oscillating (AC) magnetic fields can not only detect unknown field amplitudes but also allows detection of the field phase. The thesis also compares the performance of nonadaptive-PEA (NAPEA) with that of adaptive-PEA (QPEA) and conclude that NAPEA is superior to QPEA due to (a) better sensitivity on average, (b) consistency in sensitivity throughout the full field range, (c) comparatively less demanding measurement fidelity, and (d) for simplicity in its experimental realization. The techniques developed here can potentially have broad applicability to a wide variety of solid-state quantum systems and in the field of quantum control and measurement.