Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2601.15354 · Physical Review A

Precision limit under weak coupling with an ancillary qubit

Peng Chen, Jun Jing

quant-phSubmitted Jan 21, 2026• Announced Jan 22, 2026• 0 citations• Revised Jul 22, 2026 (v2)
v1 · Jan 21, 2026v2 · Jul 22, 2026
arXivHTMLPDF

Abstract

We propose a measurement-based quantum metrology protocol in a composite model, where the probe system (a spin ensemble) is coupled to an ancillary two-level system (qubit) with a general Heisenberg XXZ interaction. With optimized probe-ancilla coupling strengths and duration of joint evolution, the two parallel evolution paths of the probe system induced by the unconditional measurement on qubit can transform an eigenstate of the collective angular momentum operator of spin ensemble into a two-component state with a large distance in eigenspace. The quantum Fisher information about the phase encoded in the probe system of polarized states or their superposition, that could be relaxed to mixed states, can therefore manifest an exact or asymptotic quadratic scaling with respect to the probe size (spin number) $N$. The quadratic scaling behavior is found to be insensitive to the imperfect encoding operator, polarized direction of probe, and coupling strength. The phase sensitivity can approach the Heisenberg limit by virtue of the parity detection on either ancillary qubit or probe system. This work justifies that the unconditional measurement on a weakly coupled qubit could be an efficient resource to replace Greenberger-Horne-Zeilinger-type states and squeezing Hamiltonian for exceeding the standard quantum limit in metrology precision.

Journal reference
Phys. Rev. A 114, 012449 (2026)
DOI
10.1103/my6j-77x2
Comments
12 pages, 6 figures

Related papers

Achieving the Heisenberg limit of metrology via measurement on an ancillary qubit

Peng Chen, Jun Jing

In the scenario of the probe-ancilla interaction, we propose a quantum metrology protocol by the unconditional measurement on the ancillary qubit after an optimized period of joint evolution from a product state. Its key element is the construction of two parallel evolution paths by the measurement that can transform the probe system (a spin ensemble) from an eigenstate of a collective angular momentum operator $|j,m\ensuremath{\rangle}$ to a superposed state $(|j,m\ensuremath{\rangle}+|j,\ensuremath{-}m\ensuremath{\rangle})/\sqrt{2}$. With synchronous parametric encoding and qubit measurement, the quantum Fisher information about the phase encoded in the probe system with optimized initial states can exactly attain the Heisenberg scaling ${N}^{2}$ with respect to the probe size (spin number) $N$. The quadratic scaling behavior is not sensitive to the imprecise control over the joint evolution time, the time delay between encoding and measurement, and the coherence in the probe ensemble or the ancillary system that would be degraded by local dephasing. The classical Fisher information of the spin ensemble is found to saturate with its quantum counterpart, irrespective of the idle joint evolution after the parametric encoding. We suggest that both Greenberger-Horne-Zeilinger (GHZ)-like states and nonlinear Hamiltonian are not necessary resources for exceeding the standard quantum limit in metrology precision since in our protocol even thermal states can hold an asymptotic quadratic scaling.

arXiv:2505.06081•Physical Review A•Aug 12, 2025•2 citations

Criterion for qubit-assisted quantum metrology approaching Heisenberg scaling

Peng Chen, Jun Jing

We study in this work the metrology precision of a probe system coupled to an ancillary qubit. Restricting the probe-qubit coupling along only one or two directions is found to be a sufficient criterion for the effective dynamical generator to achieve the Heisenberg limit in precision. Under the criterion, the quantum Fisher information (QFI) about the to-be-estimated parameter becomes the expectation value of mean square of the effective generator with respect to the initial state of the composite system. Our criterion is justified in two distinct systems. For a bosonic probe, QFI about the displacement estimation is found to be proportional to the mean excitation number of probe. It renders a counterintuitive result that quantum metrology sensitivity can be enhanced by increasing the temperature of the probe system. For a spin-ensemble probe, QFI about both rotation-phase and magnetic-field estimation exhibit a quadratic dependence on the probe-spin number. It is found that even when the spin-ensemble is prepared as a finite-temperature state, faraway from the so-called resource states, e.g., the squeezed state or the Greenberger-Horne-Zeilinger state, QFI can still manifest a Heisenberg scaling behavior.

quant-pharXiv:2606.26167•Jun 25, 2026•0 citations

Qubit-assisted quantum metrology under a time-reversal strategy

Peng Chen, Jun Jing

We propose a quantum metrology protocol based on a two-step joint evolution of the probe system and an ancillary qubit and quantum measurement. With a proper initial state of the ancillary qubit and an optimized evolution time, the quantum Fisher information (QFI) about the phase parameter encoded in the probe system is found to be determined by the expectation value of the square of a phase generator, irrespective of the probe initial state. Consequently, even if the probe is prepared as a finite-temperature state, faraway from the so-called resource state, e.g., the squeezed spin state or the Greenberger-Horne-Zeilinger state in atomic systems, the QFI in our protocol can approach the Heisenberg scaling ${N}^{2}$ with respect to the probe size $N$. This quadratic scaling behavior shows robustness against the imperfections about the initial state of the ancillary qubit and the optimized evolution time of the whole system. Also it is not sensitive to the deviation in system parameters and the qubit decoherence. Using the time-reversal strategy and a single-shot projective measurement, the classical Fisher information (CFI) in our metrology protocol is saturated with its quantum counterpart. Our work thus provides an economical method to reach the Heisenberg limit in metrology precision with no input of entanglement or squeezing.

arXiv:2404.12649•Physical Review A•Dec 30, 2024•6 citations

Bypassing the protection-sensitivity incompatibility in quantum-error-corrected metrology via asymmetric codes

Junjie Chen, Rui Luo, Zhenyu Du +3 more

Quantum metrology surpasses the classical precision limit by encoding signals in a probe state such that signal contributions are indistinguishable and their phases accumulate coherently as a collective response. In realistic settings, scalable quantum metrology requires quantum error correction to protect the probe against noise. However, quantum error correction relies on syndrome information that distinguishes errors for identification and correction. Because signals and errors act on the same physical degrees of freedom, there is a structural incompatibility between signal-sensitivity and noise-protection in quantum-error-corrected metrology. We quantify this incompatibility by establishing trade-offs between code distance and the quantum Fisher information of code states for non-degenerate codes, quantum low-density parity-check codes, and generalized Shor codes. We bypass this limitation with asymmetric quantum error correction, in which protection is relaxed along the signal direction while being maintained in complementary directions. We construct such codes for local sensing Hamiltonians, restoring Heisenberg-limited precision while retaining a growing distance and hence protection against local perturbations in complementary directions. Strongly asymmetric quantum low-density parity-check and concatenated asymmetric constructions make the framework sparse, scalable, and continuously tunable. The associated probe states can be prepared by constant-depth adaptive circuits with optimal resource scaling.

quant-pharXiv:2512.20426•Dec 24, 2025•0 citations

Fault-Tolerant Heisenberg-Limited Quantum Metrology with Bosonic Probes

Daniel G. Li, Lorcán O Conlon, Yu-Xin Wang +3 more

Quantum sensors have been shown to enable more precise measurements than classical sensors. By using entanglement and coherent evolution, the estimation error can be made to scale better in interrogation time, photon count, and other resources, achieving Heisenberg-limited scaling. However, environmental noise and hardware errors typically destroy the coherence of the sensitive quantum states. This motivates the use of fault-tolerant techniques to create more robust quantum sensing protocols. Such fault-tolerant quantum sensing approaches have been shown to enhance sensitivity for qubit systems, but many practical sensors require bosonic probes. In this paper, we propose a fault-tolerant protocol using bosons to estimate displacements in the presence of dephasing noise. We construct an optimal error-correcting code under a mean photon-number constraint. Controlled displacements couple the probe to a repetition-encoded qubit register, while repeated boson-parity measurements and resets remove probe noise without erasing the stored logical phase. Under circuit-level bit-flip noise, a distance-$d$ code suppresses logical failures to order $p^{(d+1)/2}$. We show that, for a decay rate $γ_A$, a total sensing time $T$ and a mean photon number budget $N$, and for sufficiently small residual signals, the Fisher information scales as $NT^2$ over interrogation times of order $γ_A^{-(d+1)/2}$. This is a significant improvement over the non-fault-tolerant approach that achieves Heisenberg scaling only for a total time $\mathcal O(γ_A^{-1})$.

quant-pharXiv:2610.40405•Oct 30, 2026•0 citations

Achieving Heisenberg scaling by probe-ancilla interaction in quantum metrology

Jingyi Fan, Shengshi Pang

The Heisenberg scaling is an ultimate precision limit of parameter estimation allowed by the principles of quantum mechanics, with no counterpart in the classical realm, and has been a long-pursued goal in quantum metrology. It has been known that interactions between the probes can help reach the Heisenberg scaling without entanglement. In this paper, we show that interactions between the probes and the additional dimensions of an ancillary system may also increase the precision of parameter estimation to surpass the standard quantum limit and attain the Heisenberg scaling without entanglement, if the measurement scheme is properly designed. The quantum Fisher information exhibits periodic patterns over the evolution time, implying the existence of optimal time points for measurements that can maximize the quantum Fisher information. By implementing optimizations over the Hamiltonian, the initial states of the probes and the ancillary system, the interaction strength, and the time points for measurements, our protocol achieves the Heisenberg scaling for the parameter of the probe Hamiltonian, in terms of both evolution time and probe number. Our protocol features two aspects: (i) the Heisenberg scaling can be achieved by a product state of the probes and (ii) mere local measurement on the ancilla is sufficient, both of which reduce the quantum resources and the implementation complexity to achieve the Heisenberg scaling. The paper is concluded by the investigation of the effects of noise on this protocol.

arXiv:2407.16880•Physical Review A•Dec 3, 2024•6 citations
We propose a measurement-based quantum metrology protocol in a composite model, where the probe system (a spin ensemble) is coupled to an ancillary two-level system (qubit) with a general Heisenberg XXZ interaction. With optimized probe-ancilla coupling strengths and duration of joint evolution, the two parallel evolution paths of the probe system induced by the unconditional measurement on qubit can transform an eigenstate of the collective angular momentum operator of spin ensemble into a two-component state with a large distance in eigenspace. The quantum Fisher information about the phase encoded in the probe system of polarized states or their superposition, that could be relaxed to mixed states, can therefore manifest an exact or asymptotic quadratic scaling with respect to the probe size (spin number) NNN. The quadratic scaling behavior is found to be insensitive to the imperfect encoding operator, polarized direction of probe, and coupling strength. The phase sensitivity can approach the Heisenberg limit by virtue of the parity detection on either ancillary qubit or probe system. This work justifies that the unconditional measurement on a weakly coupled qubit could be an efficient resource to replace Greenberger-Horne-Zeilinger-type states and squeezing Hamiltonian for exceeding the standard quantum limit in metrology precision.
In the scenario of the probe-ancilla interaction, we propose a quantum metrology protocol by the unconditional measurement on the ancillary qubit after an optimized period of joint evolution from a product state. Its key element is the construction of two parallel evolution paths by the measurement that can transform the probe system (a spin ensemble) from an eigenstate of a collective angular momentum operator $|j,m\ensuremath{\rangle}$ to a superposed state $(|j,m\ensuremath{\rangle}+|j,\ensuremath{-}m\ensuremath{\rangle})/\sqrt{2}$. With synchronous parametric encoding and qubit measurement, the quantum Fisher information about the phase encoded in the probe system with optimized initial states can exactly attain the Heisenberg scaling N2{N}^{2}N2 with respect to the probe size (spin number) NNN. The quadratic scaling behavior is not sensitive to the imprecise control over the joint evolution time, the time delay between encoding and measurement, and the coherence in the probe ensemble or the ancillary system that would be degraded by local dephasing. The classical Fisher information of the spin ensemble is found to saturate with its quantum counterpart, irrespective of the idle joint evolution after the parametric encoding. We suggest that both Greenberger-Horne-Zeilinger (GHZ)-like states and nonlinear Hamiltonian are not necessary resources for exceeding the standard quantum limit in metrology precision since in our protocol even thermal states can hold an asymptotic quadratic scaling.
We study in this work the metrology precision of a probe system coupled to an ancillary qubit. Restricting the probe-qubit coupling along only one or two directions is found to be a sufficient criterion for the effective dynamical generator to achieve the Heisenberg limit in precision. Under the criterion, the quantum Fisher information (QFI) about the to-be-estimated parameter becomes the expectation value of mean square of the effective generator with respect to the initial state of the composite system. Our criterion is justified in two distinct systems. For a bosonic probe, QFI about the displacement estimation is found to be proportional to the mean excitation number of probe. It renders a counterintuitive result that quantum metrology sensitivity can be enhanced by increasing the temperature of the probe system. For a spin-ensemble probe, QFI about both rotation-phase and magnetic-field estimation exhibit a quadratic dependence on the probe-spin number. It is found that even when the spin-ensemble is prepared as a finite-temperature state, faraway from the so-called resource states, e.g., the squeezed state or the Greenberger-Horne-Zeilinger state, QFI can still manifest a Heisenberg scaling behavior.
We propose a quantum metrology protocol based on a two-step joint evolution of the probe system and an ancillary qubit and quantum measurement. With a proper initial state of the ancillary qubit and an optimized evolution time, the quantum Fisher information (QFI) about the phase parameter encoded in the probe system is found to be determined by the expectation value of the square of a phase generator, irrespective of the probe initial state. Consequently, even if the probe is prepared as a finite-temperature state, faraway from the so-called resource state, e.g., the squeezed spin state or the Greenberger-Horne-Zeilinger state in atomic systems, the QFI in our protocol can approach the Heisenberg scaling N2{N}^{2}N2 with respect to the probe size NNN. This quadratic scaling behavior shows robustness against the imperfections about the initial state of the ancillary qubit and the optimized evolution time of the whole system. Also it is not sensitive to the deviation in system parameters and the qubit decoherence. Using the time-reversal strategy and a single-shot projective measurement, the classical Fisher information (CFI) in our metrology protocol is saturated with its quantum counterpart. Our work thus provides an economical method to reach the Heisenberg limit in metrology precision with no input of entanglement or squeezing.
Quantum metrology surpasses the classical precision limit by encoding signals in a probe state such that signal contributions are indistinguishable and their phases accumulate coherently as a collective response. In realistic settings, scalable quantum metrology requires quantum error correction to protect the probe against noise. However, quantum error correction relies on syndrome information that distinguishes errors for identification and correction. Because signals and errors act on the same physical degrees of freedom, there is a structural incompatibility between signal-sensitivity and noise-protection in quantum-error-corrected metrology. We quantify this incompatibility by establishing trade-offs between code distance and the quantum Fisher information of code states for non-degenerate codes, quantum low-density parity-check codes, and generalized Shor codes. We bypass this limitation with asymmetric quantum error correction, in which protection is relaxed along the signal direction while being maintained in complementary directions. We construct such codes for local sensing Hamiltonians, restoring Heisenberg-limited precision while retaining a growing distance and hence protection against local perturbations in complementary directions. Strongly asymmetric quantum low-density parity-check and concatenated asymmetric constructions make the framework sparse, scalable, and continuously tunable. The associated probe states can be prepared by constant-depth adaptive circuits with optimal resource scaling.
Quantum sensors have been shown to enable more precise measurements than classical sensors. By using entanglement and coherent evolution, the estimation error can be made to scale better in interrogation time, photon count, and other resources, achieving Heisenberg-limited scaling. However, environmental noise and hardware errors typically destroy the coherence of the sensitive quantum states. This motivates the use of fault-tolerant techniques to create more robust quantum sensing protocols. Such fault-tolerant quantum sensing approaches have been shown to enhance sensitivity for qubit systems, but many practical sensors require bosonic probes. In this paper, we propose a fault-tolerant protocol using bosons to estimate displacements in the presence of dephasing noise. We construct an optimal error-correcting code under a mean photon-number constraint. Controlled displacements couple the probe to a repetition-encoded qubit register, while repeated boson-parity measurements and resets remove probe noise without erasing the stored logical phase. Under circuit-level bit-flip noise, a distance-ddd code suppresses logical failures to order p(d+1)/2p^{(d+1)/2}p(d+1)/2. We show that, for a decay rate γAγ_AγA​, a total sensing time TTT and a mean photon number budget NNN, and for sufficiently small residual signals, the Fisher information scales as NT2NT^2NT2 over interrogation times of order γA−(d+1)/2γ_A^{-(d+1)/2}γA−(d+1)/2​. This is a significant improvement over the non-fault-tolerant approach that achieves Heisenberg scaling only for a total time O(γA−1)\mathcal O(γ_A^{-1})O(γA−1​).
The Heisenberg scaling is an ultimate precision limit of parameter estimation allowed by the principles of quantum mechanics, with no counterpart in the classical realm, and has been a long-pursued goal in quantum metrology. It has been known that interactions between the probes can help reach the Heisenberg scaling without entanglement. In this paper, we show that interactions between the probes and the additional dimensions of an ancillary system may also increase the precision of parameter estimation to surpass the standard quantum limit and attain the Heisenberg scaling without entanglement, if the measurement scheme is properly designed. The quantum Fisher information exhibits periodic patterns over the evolution time, implying the existence of optimal time points for measurements that can maximize the quantum Fisher information. By implementing optimizations over the Hamiltonian, the initial states of the probes and the ancillary system, the interaction strength, and the time points for measurements, our protocol achieves the Heisenberg scaling for the parameter of the probe Hamiltonian, in terms of both evolution time and probe number. Our protocol features two aspects: (i) the Heisenberg scaling can be achieved by a product state of the probes and (ii) mere local measurement on the ancilla is sufficient, both of which reduce the quantum resources and the implementation complexity to achieve the Heisenberg scaling. The paper is concluded by the investigation of the effects of noise on this protocol.