Assumption-free reconstruction of quantum states from measurements is essential for benchmarking and certifying quantum devices, but it remains difficult due to the extensive measurement statistics and experimental resources it demands. An approach to alleviating these demands is provided by adaptive measurement strategies, which can yield up to a quadratic improvement in reconstruction accuracy for pure states by dynamically optimizing measurement settings during data acquisition. A key open question is whether these asymptotic advantages remain in realistic experiments, where readout is inevitably noisy. In this work, we analyze the impact of readout noise on adaptive quantum state tomography with readout-error mitigation, focusing on the challenging regime of reconstructing pure states using mixed-state estimators. Using analytical arguments based on Fisher information optimization and extensive numerical simulations using Bayesian inference, we show that any nonzero readout noise eliminates the asymptotic quadratic scaling advantage of adaptive strategies. We numerically investigate the behavior for finite measurement statistics for single- and two-qubit systems with exact readout-error mitigation and find a gradual transition from ideal to sub-optimal scaling. We furthermore investigate realistic scenarios where detector tomography is performed with a limited number of state copies for calibration, showing that insufficient detector characterization leads to estimator bias and limited reconstruction accuracy. Although our result imposes an upper bound on the reconstruction accuracy that can be achieved with adaptive strategies, we nevertheless observe numerically a constant-factor gain in reconstruction accuracy, which becomes larger as the readout noise decreases. This indicates potential practical benefits in using adaptive measurement strategies in well-calibrated experiments.
Assumption-free reconstruction of quantum states from measurements is essential for benchmarking and certifying quantum devices, but it remains difficult due to the extensive measurement statistics and experimental resources it demands. An approach to alleviating these demands is provided by adaptive measurement strategies, which can yield up to a quadratic improvement in reconstruction accuracy for pure states by dynamically optimizing measurement settings during data acquisition. A key open question is whether these asymptotic advantages remain in realistic experiments, where readout is inevitably noisy. In this work, we analyze the impact of readout noise on adaptive quantum state tomography with readout-error mitigation, focusing on the challenging regime of reconstructing pure states using mixed-state estimators. Using analytical arguments based on Fisher information optimization and extensive numerical simulations using Bayesian inference, we show that any nonzero readout noise eliminates the asymptotic quadratic scaling advantage of adaptive strategies. We numerically investigate the behavior for finite measurement statistics for single- and two-qubit systems with exact readout-error mitigation and find a gradual transition from ideal to sub-optimal scaling. We furthermore investigate realistic scenarios where detector tomography is performed with a limited number of state copies for calibration, showing that insufficient detector characterization leads to estimator bias and limited reconstruction accuracy. Although our result imposes an upper bound on the reconstruction accuracy that can be achieved with adaptive strategies, we nevertheless observe numerically a constant-factor gain in reconstruction accuracy, which becomes larger as the readout noise decreases. This indicates potential practical benefits in using adaptive measurement strategies in well-calibrated experiments.
We report an experimental realization of adaptive Bayesian quantum state tomography for two-qubit states. Our implementation is based on the adaptive experimental design strategy proposed in the work by Husz\'ar and Houlsby [F. Husz\'ar and N. M. T. Houlsby, Phys. Rev. A 85, 052120 (2012).] and provides an optimal measurement approach in terms of the information gain. We address the practical questions which one faces in any experimental application: the influence of technical noise and the behavior of the tomographic algorithm for an easy-to-implement class of factorized measurements. In an experiment with polarization states of entangled photon pairs, we observe a lower instrumental noise floor and superior reconstruction accuracy for nearly pure states of the adaptive protocol compared to a nonadaptive protocol. At the same time, we show that for the mixed states, the restriction to factorized measurements results in no advantage for adaptive measurements, so general measurements have to be used.
The field of quantum technologies has experienced explosive growth in the past decade. As hardware capabilities have advanced, quantum computing has exhibited a scaling trend analogous to Moore's law, often referred to as Rose's law, where the number of coherently controlled qubits roughly doubles every two years. Associated with such rapid growth is an equally growing need for benchmarking tools and error handling. While advancements in quantum hardware and software have mainly concentrated on enhancing gate fidelity and qubit connectivity, the progress in addressing readout errors has been relatively limited during the same period. This thesis tries to close this gap by advancing and developing new tools for information extraction in quantum systems. We do this in two different ways: In Part II, we focus on mitigating the effect of general readout errors in quantum systems. We developed a comprehensive protocol for readout-error-mitigated state tomography (REMST) and implemented it on a superconducting qubit system. The REMST protocol was designed to mitigate not only classical readout errors but also more challenging coherent and correlated readout errors. The protocol uses only a deterministic application of single-qubit readout, making it one of the most experimentally friendly approaches available. We developed a scalable version of the REMST protocol and showed numerically that it is suitable for systems with more than 100 qubits, matching the size of current state-of-the-art systems. The REMST protocol was applied to superconducting qubit experiments, where we saw an improvement in reconstruction accuracy by a factor of up to 30. In Part III, we move our focus to optimal measurement strategies. Adaptive measurement strategies promise a quadratic improvement in the statistical fluctuation of pure and close-to-pure state reconstruction by dynamically optimizing measurement settings during sampling. We investigated whether these adaptive measurement strategies were viable in realistic experimental settings. We demonstrated both analytically and in numerical simulations that going from ideal readout to noisy readout disproportionally deteriorates the quality of the adaptive measurement strategy, to a point where no asymptotic benefit exists for adaptive measurements. These results not only deepen our understanding of readout processes in superconducting qubits but also provide concrete implementations of more robust quantum measurement and tomography protocols, offering clearer insight into the interplay between readout noise and information extraction.
We introduce a fast and accurate heuristic for adaptive tomography that addresses many of the limitations of prior methods.Previous approaches were either too computationally intensive or tailored to handle special cases such as single qubits or pure states.By contrast, our approach combines the efficiency of online optimization with generally applicable and well-motivated data-processing techniques.We numerically demonstrate these advantages in several scenarios including mixed states, higher-dimensional systems, and restricted measurements.Quantum information processing (QIP) promises advantages in a wide range of different contexts, including machine learning [2-4], chemistry simulation [5][6][7], and number theory [8,9].As such, the experimental effort to build useful QIP devices has exploded in recent years.In the course of this effort, quantum tomography is a valuable tool for diagnosing and debugging small quantum devices, and has subsequently seen a variety of different advances.In particular, Bayesian approaches to tomography which are especially well suited to utilizing prior information and adapting to changing experimental conditions have developed significantly in recent years [10-13], presenting a useful experimental tool [14][15][16].In this paper we demonstrate the efficiency and accuracy of an adaptive tomography protocol that we call PAQT: practical adaptive quantum tomography.PAQT intelligently selects new measurements based on the outcomes of previous ones [10,[17][18][19][20][21].Adaptivity has been experimentally demonstrated [14,15,[22][23][24][25], but is not currently standard practice.Though adaptivity increases accuracy, the computational costs incurred outweigh that of simply repeating standard measurements many times.The PAQT approach employs a simple heuristic that can be efficiently computed between measurements, even with embedded hardware [26][27][28][29].The algorithm we propose is therefore compatible with modern experimental design and avoids an important limitation of previous approaches.We base our algorithm off of self-guided quantum tomography (SGQT), which treats adaptive tomography as a direct optimization problem rather than a new optimization problem between each measurement [30].Though this affords an efficient and easy to implement adaptive heuristic, SGQT is not without its limitations.It requires assuming that the target state is pure, and it does not return rich region estimates for a state.What PAQT achieves is to effectively combine SGQT with conventional and easily-implemented tomographic estimators, such as the Bayesian particle filter or least-squares fit (LSF) estimators.Under this approach, an experimentalist can collect data using SGQT (even if its assumptions are not met), and then post-process this data using particle filtering or LSF.The benefit of PAQT is two-fold.(1) From the point of view of traditional tomography, it gives an adaptive tomography protocol requiring only modest computational resources, as the bulk of the computational cost is offloaded to post-processing.(2) From the point of view of simulation-based optimization tomography (such as SGQT), it effectively augments the output with region estimation providing a statistically robust quantification of uncertainty.Thus, while we do not explicitly demonstrate that the improved scaling of Ferrie [30] remains in the more general case considered here, PAQT does provide a practical and efficient procedure for performing adaptive quantum tomography with rigorous statistical principles.
Abstract Quantum technologies rely heavily on accurate control and reliable readout of quantum systems. Current experiments are limited by numerous sources of noise that can only be partially captured by simple analytical models and additional characterization of the noise sources is required. We test the ability of readout error mitigation to correct noise found in systems composed of quantum two-level objects (qubits). To probe the limit of such methods, we designed a beyond-classical readout error mitigation protocol based on quantum state tomography (QST), which estimates the density matrix of a quantum system, and quantum detector tomography (QDT), which characterizes the measurement procedure. By treating readout error mitigation in the context of state tomography the method becomes largely readout mode-, architecture-, noise source-, and quantum state-independent. We implement this method on a superconducting qubit and evaluate the increase in reconstruction fidelity for QST. We characterize the performance of the method by varying important noise sources, such as suboptimal readout signal amplification, insufficient resonator photon population, off-resonant qubit drive, and effectively shortened T1 and T2 coherence. As a result, we identified noise sources for which readout error mitigation worked well, and observed decreases in readout infidelity by a factor of up to 30.
Quantum state and process tomography are typically analyzed under the assumption that devices emit independent and identically distributed (i.i.d.) states or channels. In realistic experiments, however, noise, drift, feedback, or adversarial behavior violate this assumption. We show that projected least-squares tomography remains statistically optimal even under fully adaptive state and channel preparation. Specifically, we prove that the sample complexity for reconstructing the time-averaged state or channel matches the optimal i.i.d. scaling for non-adaptive, single-copy measurements. For rank-r states, the sample complexity is O(dr2/ε2) to achieve accuracy ε in trace distance, while for process tomography it is O(d6/ε2) to achieve accuracy ε in diamond distance. Thus, dropping the i.i.d. assumption does not increase the fundamental sample complexity of quantum tomography, but only changes the interpretation of the reconstructed object.
We discuss an experimental realization of an adaptive quantum state tomography protocol. The method we suggested and tested takes advantage of a Bayesian approach to statistical inference and is naturally tailored for adaptive strategies. For pure states we observe close to 1/N scaling of infidelity with overall number of registered events N, while best non-adaptive protocols allow for 1 N scaling only. This is the theoretical limit for any tomographic protocol, and further improvement may only affect pre-factors in this power law. Also we consider particular strategies of the state reconstruction based on adequate and inadequate models and compare their scaling. Experiments have been performed for polarization qubits and ququarts, but the approach is readily adapted to any dimension. Our method does not take into account systematic errors caused, for example, by inaccuracies in retardant plates rotation. However for the reached values of infidelities of on the order of 10 – 10 we did not observe any deviations from expected behavior and were not able to identify the influence of systematic errors.