Abstract

Multipartite quantum states saturating the Heisenberg limit of sensitivity typically require full-body correlators to be prepared. On the other hand, experimentally practical Hamiltonians often involve few-body correlators only. Here, we study the metrological performances under this constraint, using tools derived from the quantum Fisher information. Our work applies to any encoding generator, also including a dependence on the parameter. We find that typical random symmetric ground states of $k$-body permutation-invariant Hamiltonians exhibit Heisenberg scaling. Finally, we establish a tradeoff between the Hamiltonian's gap, which quantifies preparation hardness, and the quantum Fisher information of the corresponding ground state.

Comments
20 pages, 6 figures, comments are welcome

Related papers

Reaching the Limits of Ground-State Metrology with Many-Body Probes

Erik L. André, Víctor Izquierdo, Ricard Puig +2 more

We investigate the physical requirements to reach the ultimate limits of ground-state metrology -- i.e., the estimation of an unknown parameter $θ$ of an $N$-body Hamiltonian via measurements on its ground state -- using many-body probes featuring either short-range or long-range interactions. We characterize the conditions to saturate two fundamental limits of the quantum Fisher information $F_θ$: the static ground-state bound $F_θ\lesssim N^2/Δ^2$, where $Δ$ is the spectral gap, and the dynamical Heisenberg limit $F_θ\lesssim N^2 τ^2$, where $τ$ is the total protocol duration. To saturate the static limit, we argue that short-range interacting systems require a spectral gap that closes with $N$. At second-order quantum critical points this leads to a universal condition on the critical exponents, $ν(d+z)=1$, which can be approached arbitrarily closely, as we show for the XXZ chain; cat-like ground states at first-order transitions provide an alternative route to static optimality. In contrast, we find that all-to-all interacting models can achieve optimality even in gapped regimes. Furthermore, reaching the dynamical bound is tightly related to the ground-state preparation time; we demonstrate that its optimal, inverse-gap profile can be obtained via local adiabatic protocols. By analyzing paradigmatic systems -- the transverse-field Ising chain, the XXZ chain, a squeezing Hamiltonian, and the two-mode Bose-Hubbard model -- we identify specific many-body probes capable of approaching both limits. Overall, our results provide a theoretical basis for the design of (local) many-body ground-state sensors operating at the ultimate limits of quantum precision.

quant-pharXiv:2610.03653•Oct 5, 2026•0 citations

Quantum metrology for a general Hamiltonian parameter

Shengshi Pang, Todd A. Brun

Quantum metrology enhances the sensitivity of parameter estimation using the distinctive resources of quantum mechanics such as entanglement. It has been shown that the precision of estimating an overall multiplicative factor of a Hamiltonian can be increased to exceed the classical limit, yet little is known about estimating a general Hamiltonian parameter. In this paper, we study this problem in detail. We find that the scaling of the estimation precision with the number of systems can always be optimized to the Heisenberg limit, while the time scaling can be quite different from that of estimating an overall multiplicative factor. We derive the generator of local parameter translation on the unitary evolution operator of the Hamiltonian, and use it to evaluate the estimation precision of the parameter and establish a general upper bound on the quantum Fisher information. The results indicate that the quantum Fisher information generally can be divided into two parts: one is quadratic in time, while the other oscillates with time. When the eigenvalues of the Hamiltonian do not depend on the parameter, the quadratic term vanishes, and the quantum Fisher information will be bounded in this case. To illustrate the results, we give an example of estimating a parameter of a magnetic field by measuring a spin-$\frac{1}{2}$ particle and compare the results for estimating the amplitude and the direction of the magnetic field.

arXiv:1407.6091•Physical Review A•Aug 25, 2014•175 citations

Random symmetric states for robust quantum metrology

Michał Oszmaniec, Remigiusz Augusiak, Christian Gogolin +3 more

We study how useful random states are for quantum metrology, i.e., surpass the classical limits imposed on precision in the canonical phase estimation scenario. First, we prove that random pure states drawn from the Hilbert space of distinguishable particles typically do not lead to super-classical scaling of precision even when allowing for local unitary optimization. Conversely, we show that random states from the symmetric subspace typically achieve the optimal Heisenberg scaling without the need for local unitary optimization. Surprisingly, the Heisenberg scaling is observed for states of arbitrarily low purity and preserved under finite particle losses. Moreover, we prove that for such states a standard photon-counting interferometric measurement suffices to typically achieve the Heisenberg scaling of precision for all possible values of the phase at the same time. Finally, we demonstrate that metrologically useful states can be prepared with short random optical circuits generated from three types of beam-splitters and a non-linear (Kerr-like) transformation.

•Feb 17, 2016•0 citations

From Dynamical to Steady-State Many-Body Metrology: Precision Limits and Their Attainability with Two-Body Interactions

Ricard Puig, Pavel Sekatski, Paolo Andrea Erdman +3 more

We consider the estimation of an unknown parameter θ via a many-body probe. The probe is initially prepared in a product state and many-body time-independent interactions enhance its θ sensitivity during the dynamics and/or in the steady state. We present bounds on the quantum Fisher information, and corresponding optimal interacting Hamiltonians, for two paradigmatic scenarios for encoding θ : (i) via unitary Hamiltonian dynamics (dynamical metrology), and (ii) in the Gibbs and diagonal ensembles (time-averaged dephased state), two ubiquitous steady states of many-body open dynamics. We then move to the specific problem of estimating the strength of a magnetic field via interacting spins and derive two-body interacting Hamiltonians that can approach the fundamental precision bounds. In this case, we additionally analyze the transient regime leading to the steady states and characterize trade-offs between equilibration times and measurement precision. Overall, our results provide a comprehensive picture of the potential of many-body control in quantum sensing.

arXiv:2412.02754•PRX Quantum•Jul 18, 2025•6 citations

Criterion for qubit-assisted quantum metrology approaching Heisenberg scaling

Peng Chen, Jun Jing

We study in this work the metrology precision of a probe system coupled to an ancillary qubit. Restricting the probe-qubit coupling along only one or two directions is found to be a sufficient criterion for the effective dynamical generator to achieve the Heisenberg limit in precision. Under the criterion, the quantum Fisher information (QFI) about the to-be-estimated parameter becomes the expectation value of mean square of the effective generator with respect to the initial state of the composite system. Our criterion is justified in two distinct systems. For a bosonic probe, QFI about the displacement estimation is found to be proportional to the mean excitation number of probe. It renders a counterintuitive result that quantum metrology sensitivity can be enhanced by increasing the temperature of the probe system. For a spin-ensemble probe, QFI about both rotation-phase and magnetic-field estimation exhibit a quadratic dependence on the probe-spin number. It is found that even when the spin-ensemble is prepared as a finite-temperature state, faraway from the so-called resource states, e.g., the squeezed state or the Greenberger-Horne-Zeilinger state, QFI can still manifest a Heisenberg scaling behavior.

quant-pharXiv:2606.26167•Jun 25, 2026•0 citations

Using the ground state of an antiferromagnetic spin-1 atomic condensate for Heisenberg-limited metrology

Ling-Na Wu, Li You

We show that the ground state of a spin-1 atomic condensate with antiferromagnetic interactions constitutes a useful resource for quantum metrology upon approaching the Heisenberg limit. Unlike a ferromagnetic condensate state where individual atomic spins are aligned in the same direction, the antiferromagnetic ground-state condensate is a condensate of spin-singlet atom pairs. The inherent correlation between paired atoms allows for parameter estimation at precisions beyond the standard quantum limit (SQL) for uncorrelated atoms. The degree of improvement over the SQL is measured by the scaled quantum Fisher information (QFI), whose dependence on the ratio of linear Zeeman shift $p$ to spin-dependent atomic interaction $c$ is studied. At a typical value of $p=0.4c$, which corresponds to a magnetic field of $28.6\phantom{\rule{4pt}{0ex}}\ensuremath{\mu}\mathrm{G}$ for $c=50\mathrm{h}$ Hz (for $^{23}\mathrm{Na}$ atom condensate in the $F=1$ state at a typical density of $\ensuremath{\sim}{10}^{14}\phantom{\rule{4pt}{0ex}}{\mathrm{cm}}^{\ensuremath{-}3}$), the scaled QFI can reach $\ensuremath{\sim}0.48N$, which approaches the limit of $0.5N$ for the twin-Fock state ${|N/2\ensuremath{\rangle}}_{+}{|N/2\ensuremath{\rangle}}_{\ensuremath{-}}$. Our work encourages experimental efforts to reach the ground state of an antiferromagnetic condensate at a extremely low magnetic field.

Physical Review A•Mar 3, 2016•11 citations
Many-body kkk-local ground states as probes for unitary quantum metrology
Multipartite quantum states saturating the Heisenberg limit of sensitivity typically require full-body correlators to be prepared. On the other hand, experimentally practical Hamiltonians often involve few-body correlators only. Here, we study the metrological performances under this constraint, using tools derived from the quantum Fisher information. Our work applies to any encoding generator, also including a dependence on the parameter. We find that typical random symmetric ground states of kkk-body permutation-invariant Hamiltonians exhibit Heisenberg scaling. Finally, we establish a tradeoff between the Hamiltonian's gap, which quantifies preparation hardness, and the quantum Fisher information of the corresponding ground state.
We investigate the physical requirements to reach the ultimate limits of ground-state metrology -- i.e., the estimation of an unknown parameter θθθ of an NNN-body Hamiltonian via measurements on its ground state -- using many-body probes featuring either short-range or long-range interactions. We characterize the conditions to saturate two fundamental limits of the quantum Fisher information FθF_θFθ​: the static ground-state bound Fθ≲N2/Δ2F_θ\lesssim N^2/Δ^2Fθ​≲N2/Δ2, where ΔΔΔ is the spectral gap, and the dynamical Heisenberg limit Fθ≲N2τ2F_θ\lesssim N^2 τ^2Fθ​≲N2τ2, where τττ is the total protocol duration. To saturate the static limit, we argue that short-range interacting systems require a spectral gap that closes with NNN. At second-order quantum critical points this leads to a universal condition on the critical exponents, ν(d+z)=1ν(d+z)=1ν(d+z)=1, which can be approached arbitrarily closely, as we show for the XXZ chain; cat-like ground states at first-order transitions provide an alternative route to static optimality. In contrast, we find that all-to-all interacting models can achieve optimality even in gapped regimes. Furthermore, reaching the dynamical bound is tightly related to the ground-state preparation time; we demonstrate that its optimal, inverse-gap profile can be obtained via local adiabatic protocols. By analyzing paradigmatic systems -- the transverse-field Ising chain, the XXZ chain, a squeezing Hamiltonian, and the two-mode Bose-Hubbard model -- we identify specific many-body probes capable of approaching both limits. Overall, our results provide a theoretical basis for the design of (local) many-body ground-state sensors operating at the ultimate limits of quantum precision.
Quantum metrology enhances the sensitivity of parameter estimation using the distinctive resources of quantum mechanics such as entanglement. It has been shown that the precision of estimating an overall multiplicative factor of a Hamiltonian can be increased to exceed the classical limit, yet little is known about estimating a general Hamiltonian parameter. In this paper, we study this problem in detail. We find that the scaling of the estimation precision with the number of systems can always be optimized to the Heisenberg limit, while the time scaling can be quite different from that of estimating an overall multiplicative factor. We derive the generator of local parameter translation on the unitary evolution operator of the Hamiltonian, and use it to evaluate the estimation precision of the parameter and establish a general upper bound on the quantum Fisher information. The results indicate that the quantum Fisher information generally can be divided into two parts: one is quadratic in time, while the other oscillates with time. When the eigenvalues of the Hamiltonian do not depend on the parameter, the quadratic term vanishes, and the quantum Fisher information will be bounded in this case. To illustrate the results, we give an example of estimating a parameter of a magnetic field by measuring a spin-12\frac{1}{2}21​ particle and compare the results for estimating the amplitude and the direction of the magnetic field.
We study how useful random states are for quantum metrology, i.e., surpass the classical limits imposed on precision in the canonical phase estimation scenario. First, we prove that random pure states drawn from the Hilbert space of distinguishable particles typically do not lead to super-classical scaling of precision even when allowing for local unitary optimization. Conversely, we show that random states from the symmetric subspace typically achieve the optimal Heisenberg scaling without the need for local unitary optimization. Surprisingly, the Heisenberg scaling is observed for states of arbitrarily low purity and preserved under finite particle losses. Moreover, we prove that for such states a standard photon-counting interferometric measurement suffices to typically achieve the Heisenberg scaling of precision for all possible values of the phase at the same time. Finally, we demonstrate that metrologically useful states can be prepared with short random optical circuits generated from three types of beam-splitters and a non-linear (Kerr-like) transformation.
We consider the estimation of an unknown parameter θ via a many-body probe. The probe is initially prepared in a product state and many-body time-independent interactions enhance its θ sensitivity during the dynamics and/or in the steady state. We present bounds on the quantum Fisher information, and corresponding optimal interacting Hamiltonians, for two paradigmatic scenarios for encoding θ : (i) via unitary Hamiltonian dynamics (dynamical metrology), and (ii) in the Gibbs and diagonal ensembles (time-averaged dephased state), two ubiquitous steady states of many-body open dynamics. We then move to the specific problem of estimating the strength of a magnetic field via interacting spins and derive two-body interacting Hamiltonians that can approach the fundamental precision bounds. In this case, we additionally analyze the transient regime leading to the steady states and characterize trade-offs between equilibration times and measurement precision. Overall, our results provide a comprehensive picture of the potential of many-body control in quantum sensing.
We study in this work the metrology precision of a probe system coupled to an ancillary qubit. Restricting the probe-qubit coupling along only one or two directions is found to be a sufficient criterion for the effective dynamical generator to achieve the Heisenberg limit in precision. Under the criterion, the quantum Fisher information (QFI) about the to-be-estimated parameter becomes the expectation value of mean square of the effective generator with respect to the initial state of the composite system. Our criterion is justified in two distinct systems. For a bosonic probe, QFI about the displacement estimation is found to be proportional to the mean excitation number of probe. It renders a counterintuitive result that quantum metrology sensitivity can be enhanced by increasing the temperature of the probe system. For a spin-ensemble probe, QFI about both rotation-phase and magnetic-field estimation exhibit a quadratic dependence on the probe-spin number. It is found that even when the spin-ensemble is prepared as a finite-temperature state, faraway from the so-called resource states, e.g., the squeezed state or the Greenberger-Horne-Zeilinger state, QFI can still manifest a Heisenberg scaling behavior.
We show that the ground state of a spin-1 atomic condensate with antiferromagnetic interactions constitutes a useful resource for quantum metrology upon approaching the Heisenberg limit. Unlike a ferromagnetic condensate state where individual atomic spins are aligned in the same direction, the antiferromagnetic ground-state condensate is a condensate of spin-singlet atom pairs. The inherent correlation between paired atoms allows for parameter estimation at precisions beyond the standard quantum limit (SQL) for uncorrelated atoms. The degree of improvement over the SQL is measured by the scaled quantum Fisher information (QFI), whose dependence on the ratio of linear Zeeman shift ppp to spin-dependent atomic interaction ccc is studied. At a typical value of p=0.4cp=0.4cp=0.4c, which corresponds to a magnetic field of $28.6\phantom{\rule{4pt}{0ex}}\ensuremath{\mu}\mathrm{G}$ for c=50hc=50\mathrm{h}c=50h Hz (for 23Na^{23}\mathrm{Na}23Na atom condensate in the F=1F=1F=1 state at a typical density of $\ensuremath{\sim}{10}^{14}\phantom{\rule{4pt}{0ex}}{\mathrm{cm}}^{\ensuremath{-}3}$), the scaled QFI can reach $\ensuremath{\sim}0.48N$, which approaches the limit of 0.5N0.5N0.5N for the twin-Fock state ${|N/2\ensuremath{\rangle}}_{+}{|N/2\ensuremath{\rangle}}_{\ensuremath{-}}$. Our work encourages experimental efforts to reach the ground state of an antiferromagnetic condensate at a extremely low magnetic field.