Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2511.15302

Calibration of single-photon cameras using radioluminescent light sources

Radek Machulka, Václav Michálek, Ondřej Haderka, Jan Peřina

quant-phphysics.opticsSubmitted Nov 19, 2025• Announced Nov 20, 2025
arXivHTMLPDF

Abstract

In this paper, we address the calibration of the quantum efficiency of single-photon cameras using radioluminescent light sources. The proposed methods are subsequently compared with absolute calibration techniques based on the detection of correlated photon pairs. Furthermore, we propose a method for transferring absolute calibration using the aforementioned radioluminescent emitters.

Comments
4 pages, 3 figures, in Czech

Related papers

Absolute self-calibration of single-photon detectors with cw and pulsed spontaneous parametric down-conversion

Ling-An Wu, Xi-Hao Chen, Yanhua Zhai +2 more

Single-photon detectors are of great importance in spectroscopy, laser ranging, astronomy and wherever weak light detection is required, so a precise knowledge of their quantum efficiency is essential, but their calibration is by no means trivial. Traditional methods need a black body radiation source or a highly attenuated laser beam as a reference standard, or an already calibrated reference detector. It is well known that absolute measurement of the quantum efficiency, absolute in the sense that the calibration is independent of any radiometric standard or the properties of another detector, can be performed using entangled twin photons generated in optical spontaneous parametric down-conversion together with a reference detector. We have performed the first proof-of-principle experiment to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is also based on the time correlation of photons emitted in parametric down-conversion, but with the introduction of a suitable time delay between the arrival times of the twin photons. Furthermore, we describe a scheme for absolute self-calibration of the quantum efficiency at different wavelengths by means of a pulsed source of nondegenerate down-converted photons. This method should have even greater potential for applications.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 31, 2006•0 citations

Measurement of quantum efficiency using correlated photon pairs and a single-detector technique

A. Czitrovszky, Alexander V. Sergienko, Peter J. Jani +1 more

A new approach is proposed to the calibration of photodetectors and the determination of the absolute value of the quantum efficiency of photon-counting photomultipliers using entangled-photon pairs. It is based on a new single-photodetector technique and a special modulation of the entangled-photon flux. The absolute values of the quantum efficiency have been determined for several photon-counting photomultipliers.

Metrologia•Oct 1, 2000•14 citations

Ray tracing with quantum correlated photons to image a three-dimensional scene

Yingwen Zhang, Antony Orth, Duncan G. England +1 more

To capture a three-dimensional (3D) image, conventional methods often require multiple two-dimensional images of the scene from different perspectives. Here we show the reconstruction of a 3D scene with a fixed camera using quantum correlated photon pairs from a single source. Correlated photon pairs are effectively mirror images of each other so, by measuring the emission position of one photon, and the emission angle of the other, the entire propagation trajectory of the pair, and, subsequently, the 3D scene, can be reconstructed. The high photon correlation and low photon flux from a quantum source also makes it well suited for 3D imaging of light sensitive samples.

arXiv:2107.13095•Physical Review A•Jan 3, 2022•28 citations

Absolute calibration of single-photon and multiplexed photon-number-resolving detectors

Lior Cohen, Y. Pilnyak, D. Istrati +3 more

Single-photon detectors are widely used in modern quantum optics experiments and applications. Like all detectors, it is important for these devices to be accurately calibrated. A single-photon detector is calibrated by determining its detection efficiency; the common method to measure this quantity requires comparison to another detector. Here, we suggest a method to measure the detection efficiency of a single-photon detector without requiring an external reference detector. Our method is valid for individual single-photon detectors as well as multiplexed detectors, which are known to be photon number resolving. The method exploits the even-number photon-statistics of a nonlinear source, as well as the nonlinear loss of a single-photon detector that occurs when multiple photons are incident simultaneously. We have analytically modeled multiplexed detectors and used the results to experimentally demonstrate the calibration of a single-photon detector without the need for an external reference detector.

arXiv:1711.03594•Physical Review A•Jul 5, 2018•26 citations

TOWARDS THE IMPLEMENTATION OF A SINGLE-PHOTON DETECTOR ABSOLUTE CALIBRATION SYSTEM WITH CORRELATED PHOTON-PAIRS

T. Ferreira da Silva, I B Couceiro, H.P. Grieneisen +1 more

Abstract − An experimental system using correlated photon pairs for absolute measurements of single-photon detectors quantum efficiency has been set up at the Brazilian National Institute of Metrology (INMETRO). The establishment of this methodology is of special significance for the absolute calibration of detectors, especially for near infrared range as an alternative to the conventional radiometric methods. This paper describes the preliminary implementation of this absolute calibration method. Our first experimental results are reported and the optimization of the system is pointed out for obtaining further improvements the near future.

•Jan 1, 2009•0 citations

Measurement of InGaAs single photon detector quantum efficiency at 1550nm

Kun Zhao, Changming Liu, Haidong Chen +1 more

Single photon detectors nowadays are widely used in numerous applications such as quantum cryptography, laser ranging, single molecule spectroscopy and so on. And the calibration of the detection efficiency is quite important for some of the applications. In recent years, researchers find that correlated photon pairs can be employed to calibrate the detection efficiency of single-photon detectors with quite high precision. Firstly, we calibrated the InGaAs single photon detector quantum efficiency at 1550nm by correlated photon pairs. Consistency between the measurement result using correlated photon pairs and the reference value is better than 0.8%. Secondly, the detectors are calibrated with an attenuated laser source. Thirdly, the two methods for measuring the quantum efficiency of single photon detectors, correlated photon pairs and laser attenuation, respectively, are discussed and analyzed in detail. Finally, results derived from the two methods have been compared with each other.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 20, 2015•1 citation
In this paper, we address the calibration of the quantum efficiency of single-photon cameras using radioluminescent light sources. The proposed methods are subsequently compared with absolute calibration techniques based on the detection of correlated photon pairs. Furthermore, we propose a method for transferring absolute calibration using the aforementioned radioluminescent emitters.
Single-photon detectors are of great importance in spectroscopy, laser ranging, astronomy and wherever weak light detection is required, so a precise knowledge of their quantum efficiency is essential, but their calibration is by no means trivial. Traditional methods need a black body radiation source or a highly attenuated laser beam as a reference standard, or an already calibrated reference detector. It is well known that absolute measurement of the quantum efficiency, absolute in the sense that the calibration is independent of any radiometric standard or the properties of another detector, can be performed using entangled twin photons generated in optical spontaneous parametric down-conversion together with a reference detector. We have performed the first proof-of-principle experiment to determine the quantum efficiency by which no second detector or reference standard is required. This absolute self-calibration method is also based on the time correlation of photons emitted in parametric down-conversion, but with the introduction of a suitable time delay between the arrival times of the twin photons. Furthermore, we describe a scheme for absolute self-calibration of the quantum efficiency at different wavelengths by means of a pulsed source of nondegenerate down-converted photons. This method should have even greater potential for applications.
To capture a three-dimensional (3D) image, conventional methods often require multiple two-dimensional images of the scene from different perspectives. Here we show the reconstruction of a 3D scene with a fixed camera using quantum correlated photon pairs from a single source. Correlated photon pairs are effectively mirror images of each other so, by measuring the emission position of one photon, and the emission angle of the other, the entire propagation trajectory of the pair, and, subsequently, the 3D scene, can be reconstructed. The high photon correlation and low photon flux from a quantum source also makes it well suited for 3D imaging of light sensitive samples.
Single-photon detectors are widely used in modern quantum optics experiments and applications. Like all detectors, it is important for these devices to be accurately calibrated. A single-photon detector is calibrated by determining its detection efficiency; the common method to measure this quantity requires comparison to another detector. Here, we suggest a method to measure the detection efficiency of a single-photon detector without requiring an external reference detector. Our method is valid for individual single-photon detectors as well as multiplexed detectors, which are known to be photon number resolving. The method exploits the even-number photon-statistics of a nonlinear source, as well as the nonlinear loss of a single-photon detector that occurs when multiple photons are incident simultaneously. We have analytically modeled multiplexed detectors and used the results to experimentally demonstrate the calibration of a single-photon detector without the need for an external reference detector.
Abstract − An experimental system using correlated photon pairs for absolute measurements of single-photon detectors quantum efficiency has been set up at the Brazilian National Institute of Metrology (INMETRO). The establishment of this methodology is of special significance for the absolute calibration of detectors, especially for near infrared range as an alternative to the conventional radiometric methods. This paper describes the preliminary implementation of this absolute calibration method. Our first experimental results are reported and the optimization of the system is pointed out for obtaining further improvements the near future.
Single photon detectors nowadays are widely used in numerous applications such as quantum cryptography, laser ranging, single molecule spectroscopy and so on. And the calibration of the detection efficiency is quite important for some of the applications. In recent years, researchers find that correlated photon pairs can be employed to calibrate the detection efficiency of single-photon detectors with quite high precision. Firstly, we calibrated the InGaAs single photon detector quantum efficiency at 1550nm by correlated photon pairs. Consistency between the measurement result using correlated photon pairs and the reference value is better than 0.8%. Secondly, the detectors are calibrated with an attenuated laser source. Thirdly, the two methods for measuring the quantum efficiency of single photon detectors, correlated photon pairs and laser attenuation, respectively, are discussed and analyzed in detail. Finally, results derived from the two methods have been compared with each other.