arXiv:2510.21085 · Physical review. B./Physical review. B

Broadband single microwave photon detector insensitive to thermal noise

Y. Q. Chai, M. Y. Wang, S. N. Wang, P. H. Ouyang, L. F. Wei

Published Jan 9, 2026• 0 citations
arXivHTMLPDF

Abstract

Thermal noise is one of the physical obstacles that constrain the achievable detection sensitivities of various detectors. Indeed, as we showed in a recent paper (PRB 111, 024501 (2025)), the usual Josephson threshold detector (JTD) operated in an equilibrium state can be utilized to implement a weak microwave signal, just approaching (but not arriving at) its energy quantum limit, even though its physical parameters have been optimized. In this letter, we further demonstrate numerically that the phase dynamics of a current-biased Josephson junction (CBJJ) can be insensitive to the always-on thermal noise if the sweep rate of the biased current is significantly high. As a consequence, the JTD can be operated alternatively in a non-equilibrium state. Based on the statistical binary detection criterion, we demonstrate how such a non-equilibrium JTD (NEJTD) can be utilized to implement the weak microwave signal, arriving at its energy quantum limit level. The dynamic range and photon-number resolvability of the proposed NEJTD are also discussed when it serves as a broadband single microwave-photon detector.

DOI
10.1103/l46m-rm5y

Related papers

Measuring weak microwave signals via a current-biased Josephson junction: Suppressing its thermal noise via fast bias current sweeps

Y. Q. Chai, M. Y. Wang, S. N. Wang +2 more

It is well known that the current-biased Josephson junction (CBJJ) can serve as a Josephson threshold detector (JTD) for the sensitive detection of weak microwave signals. Based on the recent work (PRB {\bf 111}, 024501 (2025)) on the detection sensitive limit of the usual equilibrium JTD, here we numerically demonstrate that a non-equilibrium JTD can be alternatively utilized to implement the higher sensitive detection of a weak microwave signal, arriving at its energy quantum limit. In the presence of thermal noise, we numerically simulate the phase dynamics for the CBJJ in the JTD with the different sweep rates of the biased currents, and find that the SCDs of the JTD with and without the microwave signal input show different behaviors. It is demonstrated that, depending on how high the sweep rate of the biased current being applied, the JTD can be operated in either the equilibrium- or the non-equilibrium state. Specifically, under the rapidly non-adiabatic driving, the SCDs of the JTD are obviously insensitive to the thermal noises, which means that the non-equilibrium JTD can possess a higher achievable detection sensitivity, compared with its equilibrium state counterpart. Consequently, the non-equilibrium JTD can be utilized to implement the desired single microwave-photon detection. Also, some of the achievable performance indexes, such as the dynamic range, detection bandwidth, and the photon-number resolvability, etc., of the non-equilibrium JTD have been estimated, when it serves as a wideband microwave single-photon detector.

arXiv:2510.20570•Physical review. B./Physical review. B•May 14, 2026•0 citations

Experimental demonstrations of Josephson threshold detectors for broadband microwave photons detection

J. X. He, P. H. Ouyang, Y. Q. Chai +3 more

In this Letter, we experimentally demonstrated that Josephson threshold detectors (JTDs) could be developed to implement the sensitive detection of broadband microwave photons. Beginning with the numerical simulations of the damped dynamics for the macroscopic phase particle generated by a Josephson junction (JJ), we showed that the time-domain threshold voltage state switched measurements of the JJ driven by a low-frequency triangular wave current, which could be utilized to implement the sensitive microwave photons detection. The detectable signal power can be determined by using the Kumar–Caroll index to quantify the distinguishability between two statistical distributions on the measured threshold switched durations of the JJ with and without the signal input. Experimentally, we fabricated the Al/AlOx/Al JJ and measured its threshold responses, at 50 mK temperature, to the input microwave photons at the frequency of ∼5 GHz. The experimental results indicated that the weak microwave signals, which are phenomenologically threatened by the additional thermal noise that modifies the damped phase dynamics of the JJ, can be detected by the fabricated JTD. The detectable power of the microwave signals demonstrated here was calibrated as about −92 dBm (corresponding to the photons rate of ∼2×108 photons/ms). Based on the numerical simulations for optimizing the relevant performance indicators of the detectors, we further argue that the JTDs could be utilized to achieve the sensitive detection of broadband microwave photons at the single-photon level.

arXiv:2502.14300•Applied Physics Letters•May 19, 2025•5 citations

Measuring weak microwave signals via current-biased Josephson junctions: Approaching the quantum limit of energy detection

Y. Q. Chai, S. N. Wang, P. H. Ouyang +1 more

Single-photon detection is an energy quantum limit detection (EQLD) of extremely weak electromagnetic waves. Given that the sensitivity of the conventional electromagnetic induction microwave receiver working at room temperature is very limited, as a result of the significantly strong thermal noise, here we analyze the possibility of approaching the EQLD of the weak microwave signal by using a current-biased Josephson junction (CBJJ) detector. By numerically simulating the dynamics for the phase particle of the CBJJ, we propose an approach to describe the discriminability between the probabilistically escaped events of the phase particle with and without the microwave current driving, by measuring the minimum ${d}_{\mathrm{KC}}$ index. Our predictions indicate that the experimentally demonstrated CBJJ detector possesses the ability to resolve about a dozen photons. Furthermore, with the minimum detectable signal strength and the saturation threshold, we discuss how to determine the dynamic range of the proposed CBJJ detector. The feasibility of using the proposed CBJJ detector to achieve the EQLD in a microwave band is also discussed.

arXiv:2410.23947•Physical review. B./Physical review. B•Jan 2, 2025•6 citations

Josephson-Based Scheme for the Detection of Microwave Photons

Claudio Guarcello, Alex Stephane Piedjou Komnang, C. Barone +4 more

We propose a scheme for the detection of microwave-induced photons through a current-biased Josephson junction, from the point of view of the statistical decision theory. Our analysis is based on the numerical study of the zero-voltage lifetime distribution in response to a periodic train of pulses, that mimics the absorption of photons. The statistical properties of the detection are retrieved comparing the thermally induced transitions with the distribution of the switchings to the finite voltage state due to the joint action of thermal noise and of the incident pulses. The capability to discriminate the photon arrival can be quantified through the Kumar-Caroll index, which is a good indicator of the signal-to-noise ratio. The index can be exploited to identify the system parameters best suited for the detection of weak microwave photons.

arXiv:2108.00976•Physical Review Applied•Nov 5, 2021•33 citations

Bolometric detection of Josephson radiation

Bayan Karimi, Gorm O. Steffensen, Andrew P. Higginbotham +3 more

One of the most promising approaches towards large-scale quantum computation uses devices based on many Josephson junctions. Yet, even today, open questions regarding the single junction remain unsolved, such as the detailed understanding of the quantum phase transitions, the coupling of the Josephson junction to the environment or how to improve the coherence of a superconducting qubit. Here we design and build an engineered on-chip reservoir connected to a Josephson junction that acts as an efficient bolometer for detecting the Josephson radiation under non-equilibrium, that is, biased conditions. The bolometer converts the a.c. Josephson current at microwave frequencies up to about 100 GHz into a temperature rise measured by d.c. thermometry. A circuit model based on realistic parameter values captures both the current-voltage characteristics and the measured power quantitatively. The present experiment demonstrates an efficient, wide-band, thermal detection scheme of microwave photons and provides a sensitive detector of Josephson dynamics beyond the standard conductance measurements.

Nature Nanotechnology•Aug 22, 2024•9 citations

Resonant switching current detector based on underdamped Josephson junctions

V. M. Krasnov

Current-biased Josephson junctions can act as detectors of electromagnetic radiation. At optimal conditions, their sensitivity is limited by fluctuations causing stochastic switching from the superconducting to the resistive state. This work provides a quantitative description of a stochastic switching current detector, based on an underdamped Josephson junction. It is shown that activation of a Josephson plasma resonance can greatly enhance the detector responsivity in proportion to the quality factor of the junction. The ways of tuning the detector for achieving optimal operation are discussed. For realistic parameters of Nb / Al O x / Nb tunnel junctions, the sensitivity and noise-equivalent power (NEP) can reach values of S ≃ 5 × 10 12 (V/W) and NEP ≃ 2 × 10 − 23 ( WHz − 1 / 2 ), respectively. These outstanding characteristics facilitate both bolometric and single-photon detection in microwave and terahertz ranges. Published by the American Physical Society 2024

arXiv:2403.03803•Physical Review Applied•Aug 6, 2024•9 citations
Thermal noise is one of the physical obstacles that constrain the achievable detection sensitivities of various detectors. Indeed, as we showed in a recent paper (PRB 111, 024501 (2025)), the usual Josephson threshold detector (JTD) operated in an equilibrium state can be utilized to implement a weak microwave signal, just approaching (but not arriving at) its energy quantum limit, even though its physical parameters have been optimized. In this letter, we further demonstrate numerically that the phase dynamics of a current-biased Josephson junction (CBJJ) can be insensitive to the always-on thermal noise if the sweep rate of the biased current is significantly high. As a consequence, the JTD can be operated alternatively in a non-equilibrium state. Based on the statistical binary detection criterion, we demonstrate how such a non-equilibrium JTD (NEJTD) can be utilized to implement the weak microwave signal, arriving at its energy quantum limit level. The dynamic range and photon-number resolvability of the proposed NEJTD are also discussed when it serves as a broadband single microwave-photon detector.
It is well known that the current-biased Josephson junction (CBJJ) can serve as a Josephson threshold detector (JTD) for the sensitive detection of weak microwave signals. Based on the recent work (PRB {\bf 111}, 024501 (2025)) on the detection sensitive limit of the usual equilibrium JTD, here we numerically demonstrate that a non-equilibrium JTD can be alternatively utilized to implement the higher sensitive detection of a weak microwave signal, arriving at its energy quantum limit. In the presence of thermal noise, we numerically simulate the phase dynamics for the CBJJ in the JTD with the different sweep rates of the biased currents, and find that the SCDs of the JTD with and without the microwave signal input show different behaviors. It is demonstrated that, depending on how high the sweep rate of the biased current being applied, the JTD can be operated in either the equilibrium- or the non-equilibrium state. Specifically, under the rapidly non-adiabatic driving, the SCDs of the JTD are obviously insensitive to the thermal noises, which means that the non-equilibrium JTD can possess a higher achievable detection sensitivity, compared with its equilibrium state counterpart. Consequently, the non-equilibrium JTD can be utilized to implement the desired single microwave-photon detection. Also, some of the achievable performance indexes, such as the dynamic range, detection bandwidth, and the photon-number resolvability, etc., of the non-equilibrium JTD have been estimated, when it serves as a wideband microwave single-photon detector.
In this Letter, we experimentally demonstrated that Josephson threshold detectors (JTDs) could be developed to implement the sensitive detection of broadband microwave photons. Beginning with the numerical simulations of the damped dynamics for the macroscopic phase particle generated by a Josephson junction (JJ), we showed that the time-domain threshold voltage state switched measurements of the JJ driven by a low-frequency triangular wave current, which could be utilized to implement the sensitive microwave photons detection. The detectable signal power can be determined by using the Kumar–Caroll index to quantify the distinguishability between two statistical distributions on the measured threshold switched durations of the JJ with and without the signal input. Experimentally, we fabricated the Al/AlOx/Al JJ and measured its threshold responses, at 50 mK temperature, to the input microwave photons at the frequency of ∼5 GHz. The experimental results indicated that the weak microwave signals, which are phenomenologically threatened by the additional thermal noise that modifies the damped phase dynamics of the JJ, can be detected by the fabricated JTD. The detectable power of the microwave signals demonstrated here was calibrated as about −92 dBm (corresponding to the photons rate of ∼2×108 photons/ms). Based on the numerical simulations for optimizing the relevant performance indicators of the detectors, we further argue that the JTDs could be utilized to achieve the sensitive detection of broadband microwave photons at the single-photon level.
Single-photon detection is an energy quantum limit detection (EQLD) of extremely weak electromagnetic waves. Given that the sensitivity of the conventional electromagnetic induction microwave receiver working at room temperature is very limited, as a result of the significantly strong thermal noise, here we analyze the possibility of approaching the EQLD of the weak microwave signal by using a current-biased Josephson junction (CBJJ) detector. By numerically simulating the dynamics for the phase particle of the CBJJ, we propose an approach to describe the discriminability between the probabilistically escaped events of the phase particle with and without the microwave current driving, by measuring the minimum dKC{d}_{\mathrm{KC}}dKC​ index. Our predictions indicate that the experimentally demonstrated CBJJ detector possesses the ability to resolve about a dozen photons. Furthermore, with the minimum detectable signal strength and the saturation threshold, we discuss how to determine the dynamic range of the proposed CBJJ detector. The feasibility of using the proposed CBJJ detector to achieve the EQLD in a microwave band is also discussed.
We propose a scheme for the detection of microwave-induced photons through a current-biased Josephson junction, from the point of view of the statistical decision theory. Our analysis is based on the numerical study of the zero-voltage lifetime distribution in response to a periodic train of pulses, that mimics the absorption of photons. The statistical properties of the detection are retrieved comparing the thermally induced transitions with the distribution of the switchings to the finite voltage state due to the joint action of thermal noise and of the incident pulses. The capability to discriminate the photon arrival can be quantified through the Kumar-Caroll index, which is a good indicator of the signal-to-noise ratio. The index can be exploited to identify the system parameters best suited for the detection of weak microwave photons.
One of the most promising approaches towards large-scale quantum computation uses devices based on many Josephson junctions. Yet, even today, open questions regarding the single junction remain unsolved, such as the detailed understanding of the quantum phase transitions, the coupling of the Josephson junction to the environment or how to improve the coherence of a superconducting qubit. Here we design and build an engineered on-chip reservoir connected to a Josephson junction that acts as an efficient bolometer for detecting the Josephson radiation under non-equilibrium, that is, biased conditions. The bolometer converts the a.c. Josephson current at microwave frequencies up to about 100 GHz into a temperature rise measured by d.c. thermometry. A circuit model based on realistic parameter values captures both the current-voltage characteristics and the measured power quantitatively. The present experiment demonstrates an efficient, wide-band, thermal detection scheme of microwave photons and provides a sensitive detector of Josephson dynamics beyond the standard conductance measurements.
Current-biased Josephson junctions can act as detectors of electromagnetic radiation. At optimal conditions, their sensitivity is limited by fluctuations causing stochastic switching from the superconducting to the resistive state. This work provides a quantitative description of a stochastic switching current detector, based on an underdamped Josephson junction. It is shown that activation of a Josephson plasma resonance can greatly enhance the detector responsivity in proportion to the quality factor of the junction. The ways of tuning the detector for achieving optimal operation are discussed. For realistic parameters of Nb / Al O x / Nb tunnel junctions, the sensitivity and noise-equivalent power (NEP) can reach values of S ≃ 5 × 10 12 (V/W) and NEP ≃ 2 × 10 − 23 ( WHz − 1 / 2 ), respectively. These outstanding characteristics facilitate both bolometric and single-photon detection in microwave and terahertz ranges. Published by the American Physical Society 2024