Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2509.03349 · Optics Letters

Low-coherence interferometry with undetected mid-infrared photons in the high-gain regime

Giovanni Zotti, D. B. Horoshko, Mikhail I. Kolobov, Yoad Michael, Ziv Gefen, Maria V. Chekhova, Kazuki Hashimoto

Published Nov 12, 2025• 1 citation
arXivHTMLPDF

Abstract

We develop a high-parametric-gain SU(1,1) interferometer based on an aperiodically poled potassium titanyl phosphate (apKTP) crystal, enabling frequency-domain low-coherence interferometry with undetected mid-infrared photons. The system achieves a signal-to-noise ratio as high as 40 dB and axial resolution of 30 μm, with a 3 μm-centered idler beam. By increasing the poling-period range, we also improve the axial resolution to 17 μm, demonstrating a straightforward route to enhance the performance by working on the crystal design.

DOI
10.1364/ol.578129

Related papers

Fourier-domain low-coherence interferometry with undetected mid-infrared photons in the high-gain regime

Giovanni Zotti, Kazuki Hashimoto, D. B. Horoshko +4 more

We develop a high-parametric-gain SU(1,1) interferometer with an aperiodically-poled KTP crystal and demonstrate Fourier-domain low-coherence interferometry with undetected mid-infrared photons.

•Jan 1, 2025•0 citations

Fourier-transform infrared spectroscopy with undetected photons from high-gain spontaneous parametric down-conversion

Kazuki Hashimoto, D. B. Horoshko, Mikhail I. Kolobov +3 more

Abstract Fourier-transform infrared spectroscopy (FTIR) is an indispensable analytical method that allows label-free identification of substances via fundamental molecular vibrations. However, traditional FTIR spectrometers require mid-infrared (MIR) elements, including low-efficiency MIR photodetectors. SU(1,1) interferometry has previously enabled FTIR with undetected MIR photons via spontaneous parametric down-conversion in the low-parametric-gain regime, where the number of photons per mode is much less than one and sensitive photodetectors are needed. In this work, we develop a high-parametric-gain SU(1,1) interferometer for MIR-range FTIR with undetected photons. Using our method, we demonstrate three major advantages: a high photon number at the interferometer output, a considerably lower photon number at the sample, and improved interference contrast. In addition, we broaden the spectral range of the interferometer by aperiodic poling in the gain medium. Exploiting the broadband SU(1,1) interferometer, we measure and evaluate the MIR absorption spectra of polymers in the 3-μm region.

arXiv:2403.05423•Communications Physics•Jul 4, 2024•21 citations

Broadband Sensing with Undetected Photons with Strong Parametric Amplification

Kazuki Hashimoto, Maria V. Chekhova

We develop an SU(1,1) interferometer with an aperiodically-poled LiNbO3 crystal in the high-parametric-gain regime to demonstrate Fourier-transform spectroscopy and optical coherence tomography with undetected photons.

•Jan 1, 2023•0 citations

Broadband Spectroscopy and Interferometry with Undetected Photons at Strong Parametric Amplification

Kazuki Hashimoto, D. B. Horoshko, Maria V. Chekhova

Abstract Nonlinear interferometry with entangled photons allows for characterizing a sample without detecting the photons interacting with it. This method enables highly sensitive optical sensing in the wavelength regions where efficient detectors are still under development. Recently, nonlinear interferometry has been applied to interferometric measurement techniques with broadband light sources, such as Fourier‐transform infrared spectroscopy and infrared optical coherence tomography. However, they have been demonstrated with photon pairs produced through spontaneous parametric down‐conversion (SPDC) at a low parametric gain, where the average number of photons per mode is much smaller than one. The regime of high‐gain SPDC offers several important advantages, such as the amplification of light after its interaction with the sample and a large number of photons per mode at the interferometer output. This work presents broadband spectroscopy and high‐resolution optical coherence tomography with undetected photons generated via high‐gain SPDC in an aperiodically poled lithium niobate crystal. To prove the principle, reflective Fourier‐transform near‐infrared spectroscopy with a spectral bandwidth of 17 THz and optical coherence tomography with an axial resolution of 11 µm are demonstrated.

arXiv:2309.08218•Advanced Quantum Technologies•Dec 24, 2023•16 citations

Frequency-domain optical coherence tomography with undetected mid-infrared photons

Aron Vanselow, Paul Kaufmann, Ivan Zorin +3 more

Mid-infrared (mid-IR) light scatters much less than shorter wavelengths, allowing greatly enhanced penetration depths for optical imaging techniques such as optical coherence tomography (OCT). However, both detection and broadband sources in the mid-IR are technologically challenging. Interfering entangled photons in a nonlinear interferometer enables sensing with undetected photons, making mid-IR sources and detectors obsolete. Here we implement mid-IR frequency-domain OCT based on ultra-broadband entangled photon pairs spanning from 3.3 to 4.3 µm. We demonstrate 10 µm axial and 20 µm lateral resolution 2D and 3D imaging of strongly scattering ceramic and paint samples. By intrinsically being limited only by shot noise, we observe times more sensitivity per integration time and power of the probe light. Together with the vastly reduced footprint and technical complexity, our technique can outperform conventional approaches with classical mid-IR light sources.

arXiv:2006.07400•Optica•Oct 28, 2020•109 citations

Dual Pump Wavelength Frequency-Domain Optical Coherence Tomography with undetected Mid-infrared Photons

Rajshree Swarnkar, Marlon Placke, Aron Vanselow +2 more

We implement a mid-infrared optical coherence tomography in a nonlinear optical interferometer using two different pump wavelengths for spontaneous parametric down conversion to enhance its axial resolution for the depth scans of highly scattering materials.

Quantum 2.0 Conference and Exhibition•Jan 1, 2024•0 citations
We develop a high-parametric-gain SU(1,1) interferometer based on an aperiodically poled potassium titanyl phosphate (apKTP) crystal, enabling frequency-domain low-coherence interferometry with undetected mid-infrared photons. The system achieves a signal-to-noise ratio as high as 40 dB and axial resolution of 30 μm, with a 3 μm-centered idler beam. By increasing the poling-period range, we also improve the axial resolution to 17 μm, demonstrating a straightforward route to enhance the performance by working on the crystal design.
Abstract Fourier-transform infrared spectroscopy (FTIR) is an indispensable analytical method that allows label-free identification of substances via fundamental molecular vibrations. However, traditional FTIR spectrometers require mid-infrared (MIR) elements, including low-efficiency MIR photodetectors. SU(1,1) interferometry has previously enabled FTIR with undetected MIR photons via spontaneous parametric down-conversion in the low-parametric-gain regime, where the number of photons per mode is much less than one and sensitive photodetectors are needed. In this work, we develop a high-parametric-gain SU(1,1) interferometer for MIR-range FTIR with undetected photons. Using our method, we demonstrate three major advantages: a high photon number at the interferometer output, a considerably lower photon number at the sample, and improved interference contrast. In addition, we broaden the spectral range of the interferometer by aperiodic poling in the gain medium. Exploiting the broadband SU(1,1) interferometer, we measure and evaluate the MIR absorption spectra of polymers in the 3-μm region.
Abstract Nonlinear interferometry with entangled photons allows for characterizing a sample without detecting the photons interacting with it. This method enables highly sensitive optical sensing in the wavelength regions where efficient detectors are still under development. Recently, nonlinear interferometry has been applied to interferometric measurement techniques with broadband light sources, such as Fourier‐transform infrared spectroscopy and infrared optical coherence tomography. However, they have been demonstrated with photon pairs produced through spontaneous parametric down‐conversion (SPDC) at a low parametric gain, where the average number of photons per mode is much smaller than one. The regime of high‐gain SPDC offers several important advantages, such as the amplification of light after its interaction with the sample and a large number of photons per mode at the interferometer output. This work presents broadband spectroscopy and high‐resolution optical coherence tomography with undetected photons generated via high‐gain SPDC in an aperiodically poled lithium niobate crystal. To prove the principle, reflective Fourier‐transform near‐infrared spectroscopy with a spectral bandwidth of 17 THz and optical coherence tomography with an axial resolution of 11 µm are demonstrated.
Mid-infrared (mid-IR) light scatters much less than shorter wavelengths, allowing greatly enhanced penetration depths for optical imaging techniques such as optical coherence tomography (OCT). However, both detection and broadband sources in the mid-IR are technologically challenging. Interfering entangled photons in a nonlinear interferometer enables sensing with undetected photons, making mid-IR sources and detectors obsolete. Here we implement mid-IR frequency-domain OCT based on ultra-broadband entangled photon pairs spanning from 3.3 to 4.3 µm. We demonstrate 10 µm axial and 20 µm lateral resolution 2D and 3D imaging of strongly scattering ceramic and paint samples. By intrinsically being limited only by shot noise, we observe times more sensitivity per integration time and power of the probe light. Together with the vastly reduced footprint and technical complexity, our technique can outperform conventional approaches with classical mid-IR light sources.