Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum 2.0 Conference and Exhibition

Dual Pump Wavelength Frequency-Domain Optical Coherence Tomography with undetected Mid-infrared Photons

Rajshree Swarnkar, Marlon Placke, Aron Vanselow, Helen M. Chrzanowski, Sven Ramelow

Published Jan 1, 2024• 0 citations
Publisher

Abstract

We implement a mid-infrared optical coherence tomography in a nonlinear optical interferometer using two different pump wavelengths for spontaneous parametric down conversion to enhance its axial resolution for the depth scans of highly scattering materials.
DOI
10.1364/quantum.2024.qtu3a.47

Related papers

Frequency-domain optical coherence tomography with undetected mid-infrared photons

Aron Vanselow, Paul Kaufmann, Ivan Zorin +3 more

Mid-infrared (mid-IR) light scatters much less than shorter wavelengths, allowing greatly enhanced penetration depths for optical imaging techniques such as optical coherence tomography (OCT). However, both detection and broadband sources in the mid-IR are technologically challenging. Interfering entangled photons in a nonlinear interferometer enables sensing with undetected photons, making mid-IR sources and detectors obsolete. Here we implement mid-IR frequency-domain OCT based on ultra-broadband entangled photon pairs spanning from 3.3 to 4.3 µm. We demonstrate 10 µm axial and 20 µm lateral resolution 2D and 3D imaging of strongly scattering ceramic and paint samples. By intrinsically being limited only by shot noise, we observe times more sensitivity per integration time and power of the probe light. Together with the vastly reduced footprint and technical complexity, our technique can outperform conventional approaches with classical mid-IR light sources.

arXiv:2006.07400•Optica•Oct 28, 2020•109 citations

Tunable optical coherence tomography in the infrared range using visible photons

Anna V. Paterova, Hongzhi Yang, Chengwu An +2 more

Optical coherence tomography (OCT) is an appealing technique for bio-imaging, medicine, and material analysis. For many applications, OCT in mid- and far-infrared (IR) leads to significantly more accurate results. Reported mid-IR OCT systems require light sources and photodetectors which operate in mid-IR range. These devices are expensive and need cryogenic cooling. Here, we report a proof-of-concept demonstration of a wavelength tunable IR OCT technique with detection of only visible range photons. Our method is based on the nonlinear interference of frequency correlated photon pairs. The nonlinear crystal, introduced in the Michelson-type interferometer, generates photon pairs with one photon in the visible and another in the IR range. The intensity of detected visible photons depends on the phase and loss of IR photons, which interact with the sample under study. This enables us to characterize sample properties and perform imaging in the IR range by detecting visible photons. The technique possesses broad wavelength tunability and yields a fair axial and lateral resolution, which can be tailored to the specific application. The work contributes to the development of versatile 3D imaging and material characterization systems working in a broad range of IR wavelengths, which do not require the use of IR-range light sources and photodetectors.

arXiv:1710.02343•Quantum Science and Technology•Mar 9, 2018•115 citations

Dispersion in nonlinear interferometry: implications for optical coherence tomography with undetected photons

Ivan Zorin, Paul Gattinger

Nonlinear SU(1,1) quantum interferometers based on non-degenerate optical parametric down-conversion exhibit strong unbalanced group velocity dispersion (GVD). This feature is intrinsic to this type of interferometer as correlated photons of vastly different frequencies propagate through a dispersive nonlinear crystal; consequently, the dispersion arises from the source itself. The resulting GVD degrades the axial point-spread function (PSF) in optical coherence tomography (OCT) with undetected photons; and physical compensation is less straightforward, in particular for non-degenerate broadband regimes due to the limited number of suitable materials. In this contribution, we analyze dispersion in bulk nonlinear interferometry and describe its implications for OCT imaging. Aspects of hardware compensation are addressed, and a novel empirical numerical method of compensation is proposed. The approach is based on the extraction of the phase component directly from the time-domain modality (high precision linearized quantum Fourier transform infrared spectrometer) and its injection into the mid-IR spectral-domain OCT signals (central wavelength of around 3770 nm) before the Fourier transform. The proposed method is compared with an alternative numerical technique. The results demonstrate a 2.2-fold improvement in axial resolution and outperform the alternative correction method in overall imaging performance.

physics.opticsCross-listedarXiv:2602.05653•Feb 6, 2026•0 citations

Michelson and Mach-Zehnder Hybrid Interferometer for Undetected-Photon Optical Coherence Tomography at Infrared Wavelength

Eun Mi Kim, Sun Kyung Lee, Sang Min Lee +2 more

Wavelength-domain optical coherence tomography is demonstrated at infrared wavelength through measurement of visible photons from a hybrid-type induced-coherence interferometer. Interference visibility is maximized by optimizing relevant heralding efficiencies between photons of the inter-band entangled pairs.

•Jan 1, 2023•0 citations

Fourier-domain low-coherence interferometry with undetected mid-infrared photons in the high-gain regime

Giovanni Zotti, Kazuki Hashimoto, D. B. Horoshko +4 more

We develop a high-parametric-gain SU(1,1) interferometer with an aperiodically-poled KTP crystal and demonstrate Fourier-domain low-coherence interferometry with undetected mid-infrared photons.

•Jan 1, 2025•0 citations

Dispersion in nonlinear interferometry: implications for optical coherence tomography with undetected photons

Ivan Zorin, Paul Gattinger

Abstract Nonlinear SU(1,1) quantum interferometers based on non-degenerate optical parametric down-conversion exhibit strong unbalanced group velocity dispersion (GVD). This feature is intrinsic to this type of interferometer, as correlated photons of vastly different frequencies propagate through a dispersive nonlinear crystal; consequently, the dispersion arises from the source itself. The resulting GVD degrades the axial point-spread function in optical coherence tomography (OCT) with undetected photons; and physical compensation is not straightforward, in particular for non-degenerate broadband regimes due to the limited number of suitable materials. In this contribution, we analyze dispersion in bulk nonlinear interferometry and describe its implications for OCT imaging. Aspects of hardware compensation are addressed, and a novel empirical numerical method of compensation is proposed. The approach is based on the extraction of the phase component directly from the time-domain modality (high-precision linearized quantum Fourier transform infrared spectrometer) and its injection into the mid-infrared spectral-domain OCT signals (central wavelength of around 3770 nm) before the Fourier transform. The proposed method is evaluated using alternative numerical techniques as baseline references. The results demonstrate a 2.2-fold improvement in axial resolution in representative measurements.

Journal of Physics Photonics•Mar 1, 2026•1 citation
Mid-infrared (mid-IR) light scatters much less than shorter wavelengths, allowing greatly enhanced penetration depths for optical imaging techniques such as optical coherence tomography (OCT). However, both detection and broadband sources in the mid-IR are technologically challenging. Interfering entangled photons in a nonlinear interferometer enables sensing with undetected photons, making mid-IR sources and detectors obsolete. Here we implement mid-IR frequency-domain OCT based on ultra-broadband entangled photon pairs spanning from 3.3 to 4.3 µm. We demonstrate 10 µm axial and 20 µm lateral resolution 2D and 3D imaging of strongly scattering ceramic and paint samples. By intrinsically being limited only by shot noise, we observe times more sensitivity per integration time and power of the probe light. Together with the vastly reduced footprint and technical complexity, our technique can outperform conventional approaches with classical mid-IR light sources.
Optical coherence tomography (OCT) is an appealing technique for bio-imaging, medicine, and material analysis. For many applications, OCT in mid- and far-infrared (IR) leads to significantly more accurate results. Reported mid-IR OCT systems require light sources and photodetectors which operate in mid-IR range. These devices are expensive and need cryogenic cooling. Here, we report a proof-of-concept demonstration of a wavelength tunable IR OCT technique with detection of only visible range photons. Our method is based on the nonlinear interference of frequency correlated photon pairs. The nonlinear crystal, introduced in the Michelson-type interferometer, generates photon pairs with one photon in the visible and another in the IR range. The intensity of detected visible photons depends on the phase and loss of IR photons, which interact with the sample under study. This enables us to characterize sample properties and perform imaging in the IR range by detecting visible photons. The technique possesses broad wavelength tunability and yields a fair axial and lateral resolution, which can be tailored to the specific application. The work contributes to the development of versatile 3D imaging and material characterization systems working in a broad range of IR wavelengths, which do not require the use of IR-range light sources and photodetectors.
Nonlinear SU(1,1) quantum interferometers based on non-degenerate optical parametric down-conversion exhibit strong unbalanced group velocity dispersion (GVD). This feature is intrinsic to this type of interferometer as correlated photons of vastly different frequencies propagate through a dispersive nonlinear crystal; consequently, the dispersion arises from the source itself. The resulting GVD degrades the axial point-spread function (PSF) in optical coherence tomography (OCT) with undetected photons; and physical compensation is less straightforward, in particular for non-degenerate broadband regimes due to the limited number of suitable materials. In this contribution, we analyze dispersion in bulk nonlinear interferometry and describe its implications for OCT imaging. Aspects of hardware compensation are addressed, and a novel empirical numerical method of compensation is proposed. The approach is based on the extraction of the phase component directly from the time-domain modality (high precision linearized quantum Fourier transform infrared spectrometer) and its injection into the mid-IR spectral-domain OCT signals (central wavelength of around 3770 nm) before the Fourier transform. The proposed method is compared with an alternative numerical technique. The results demonstrate a 2.2-fold improvement in axial resolution and outperform the alternative correction method in overall imaging performance.
Abstract Nonlinear SU(1,1) quantum interferometers based on non-degenerate optical parametric down-conversion exhibit strong unbalanced group velocity dispersion (GVD). This feature is intrinsic to this type of interferometer, as correlated photons of vastly different frequencies propagate through a dispersive nonlinear crystal; consequently, the dispersion arises from the source itself. The resulting GVD degrades the axial point-spread function in optical coherence tomography (OCT) with undetected photons; and physical compensation is not straightforward, in particular for non-degenerate broadband regimes due to the limited number of suitable materials. In this contribution, we analyze dispersion in bulk nonlinear interferometry and describe its implications for OCT imaging. Aspects of hardware compensation are addressed, and a novel empirical numerical method of compensation is proposed. The approach is based on the extraction of the phase component directly from the time-domain modality (high-precision linearized quantum Fourier transform infrared spectrometer) and its injection into the mid-infrared spectral-domain OCT signals (central wavelength of around 3770 nm) before the Fourier transform. The proposed method is evaluated using alternative numerical techniques as baseline references. The results demonstrate a 2.2-fold improvement in axial resolution in representative measurements.