We quantify how squeezed light can reduce quantum measurement noise to levels below the standard quantum limit in impulse measurements with mechanical detectors. The broadband nature of the signal implies that frequency-dependent squeezing performs better than frequency-independent squeezing. We calculate the optimal scaling of the impulse sensitivity with the squeezing strength and quantify degradations due to photodetection losses. Even for lossless measurement, we find there exists a fundamental limit to the benefit of squeezing that depends only on the system's mechanical properties.
We quantify how squeezed light can reduce quantum measurement noise to levels below the standard quantum limit in impulse measurements with mechanical detectors. The broadband nature of the signal implies that frequency-dependent squeezing performs better than frequency-independent squeezing. We calculate the optimal scaling of the impulse sensitivity with the squeezing strength and quantify degradations due to photodetection losses. Even for lossless measurement, we find there exists a fundamental limit to the benefit of squeezing that depends only on the system's mechanical properties.
Optomechanical sensors are capable of transducing external perturbations to resolvable optical signals. A particular regime of interest is that of high-bandwidth force detection, where an impulse is delivered to the system over a short period of time. Exceedingly sensitive impulse detection has been proposed to observe very weak signals like those due to long-range interactions with dark matter that require much higher sensitivities than current sensors can provide. Quantum resources to go beyond the traditional standard quantum limit of these sensors include squeezing of the light used to transduce the signal, backaction evasion by measuring the optimal quadrature, and quantum nondemolition (QND) measurements that reduce backaction directly. These methods have been developed in the context of gravitational wave detection for target frequencies in the audio band range. Here, we provide the theoretical limits to quantum noise reduction for higher and broader frequency targets, such as those from dark matter signals, while combining quantum-enhanced readout techniques based on squeezed light and QND measurements with optomechanical sensors. We demonstrate that backaction evasion through QND techniques dramatically reduces the technical challenges presented when using squeezed light for broadband force detection, paving the way for combining multiple quantum noise reduction techniques for enhanced sensitivity in the context of impulse metrology.
We propose a protocol to measure impulses beyond the standard quantum limit. The protocol reduces noise in all three spatial dimensions and consists of squeezing a mechanical system's state via a series of jumps in the frequency of the harmonic potential. We quantify how decoherence in a realistic system of an optically levitated, dielectric nanoparticle limits the ultimate sensitivity. We predict that $\sim$10 dB of squeezing is achievable with current technology, enabling quantum-enhanced detection of weak impulses.
Quantum optical sensors are ubiquitous in various fields of research, from biological or medical sensors to large-scale experiments searching for dark matter or gravitational waves. Gravitational-wave detectors have been very successful in implementing cavities and quantum squeezed light for enhancing sensitivity to signals from black hole or neutron star mergers. However, the sensitivity to weak forces is limited by the available energy and the optical decoherence in the system. Here, we derive the fundamental sensitivity limit of cavity- and squeezed-light-enhanced interferometers with optical loss. This limit is attained by the optimal use of an additional internal squeeze operation, which allows the mitigation of readout loss. We demonstrate the application of internal squeezing to various scenarios and confirm that it indeed allows one to reach the best sensitivity in cavity- and squeezed-light-enhanced linear force sensors. Our work establishes the groundwork for the future development of optimal sensors in real-world scenarios where, up until now, the application of squeezed light was curtailed by various sources of decoherence.
Quantum noise imposes a fundamental limitation on the sensitivity of interferometric gravitationalwave detectors like LIGO, manifesting as shot noise and quantum radiation pressure noise.Here, we present the first realization of frequency-dependent squeezing in full-scale gravitational-wave detectors, resulting in the reduction of both shot noise and quantum radiation pressure noise, with broadband detector enhancement from tens of hertz to several kilohertz.In the LIGO Hanford detector, squeezing reduced the detector noise amplitude by a factor of 1.6 (4.0 dB) near 1 kHz; in the Livingston detector, the noise reduction was a factor of 1.9 (5.8 dB).These improvements directly impact LIGO's scientific output for high-frequency sources (e.g., binary neutron star postmerger physics).The improved lowfrequency sensitivity, which boosted the detector range by 15%-18% with respect to no squeezing, corresponds to an increase in the astrophysical detection rate of up to 65%.Frequency-dependent squeezing was enabled by the addition of a 300-meter-long filter cavity to each detector as part of the LIGO Aþ upgrade.
A phase-sensitive (PS) heterodyne detector is intrinsically resistant to classical noises and useful in measurement of low-frequency signals below the shot noise. Despite the existence of image band vacuum, we show that the quantum-noise power level of this heterodyne detector sensing a coherent signal is exactly one light quantum per measurement time, i.e., twice the vacuum fluctuation power, which can be further reduced by use of squeezed light. We then report on an experiment on a PS heterodyne detector with a 10 Hz 1.0×10−18 W optical signal (1064 nm wavelength) at its input. The noise floor of the unmodulated coherent light is 2.2(±0.1)×10−19 W/Hz from 2 Hz to 20 Hz, and the signal-to-noise ratio is about 6.6 dB for the measured signal when the resolution bandwidth is 1 Hz. The quantum noise floor is reduced by 1.6(±0.3)dB when squeezed light is used, and the sub-shot-noise power spectral density is 1.6(±0.1)×10−19 W/Hz between 2 Hz and 20 Hz. This work should be an important advance towards squeezing-improved precision measurements of low-frequency signals with heterodyne detectors, including audio-band gravitational-wave detection.
Quantum noise is one of the limiting factors in laser-interferometric gravitational-wave (GW) detectors. The application of squeezed states in these interferometers allows the reduction of quantum noise in one quadrature. Due to opto-mechanical coupling in a GW detector the squeezed quadrature needs to be rotated within the spectrum to achieve a broadband noise reduction. So far, the implementation of additional filter cavities is considered that allow for the optimal, frequency-dependent rotation of the squeezed quadrature. However, these cavities need to have low loss, a length in the order of \unit[100]{m} and must be situated in the vacuum system, making them cost-intensive. In 2017, Ma and coworkers proposed a scheme for the broadband quantum-noise reduction without the need of additional filter cavities. It was shown by Brown et al. that a similar scheme can be used to broadband-enhance interferometers with a detuned signal-recycling cavity. Here, we performed a proof-of-principle experiment of the proposal on a table-top-scale. Squeezed states were produced detuned to the carrier field of a \unit[2.5]{m}-linear cavity and read out in a bichromatic homodyne detection. The frequencies of the lower and upper local oscillator were at entangled sidebands of the squeezed field. Depending on the relations between the involved frequencies, we can address both variants of the proposal. We show, that the frequency-dependences of the resulting noise spectra fit to a theoretical model we derived from the theory used by Ma et al. With this work we set the path towards an implementation of these schemes in a GW-detector prototype, where the compatibility of the approach with a low-frequency suspended interferometer can be tested. Moreover, we used the same setup to show nonclassical interferometer enhancement at low frequencies by high-frequency squeezed states. Here, a heterodyne readout scheme was implemented to avoid limiting noises at low frequencies. The application of squeezed states centered around the local oscillator frequency yielded an improvement in signal-to-noise ratio of $\unit[3.4]{dB}\pm\unit[0.3]{dB}$. Additionally, I designed, built and characterized a compact source of squeezed vacuum-states at \unit[1064]{nm} with a footprint of just $\unit[0.8]{m^2}$. I show measurements of squeezed states from this source with a reduction of quantum noise of $\unit[10.7]{dB}\pm\unit[0.2]{dB}$ below the vacuum noise and present a noise reduction in the frequency range from \unit[70]{kHz} to \unit[65]{MHz}.